acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Dental Instruments”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Tactile perception of roughness to assess activity in artificial initial caries lesions with a novel force-controlled probe

    Stefania MARTIGNON, Gina Alejandra CASTIBLANCO-RUBIO, Mariana Minabel BRAGA e mais 5Brazilian Oral Research2022

    Abstract Roughness-tactile perception is part of activity assessment in initial-caries-lesions. Hypothesizing that a probe’s design influences this examiner’s assessment, four probes were designed. The aims of this study were to select the probe with highest inter-/intra-examiners’ roughness-assessment agreement and…

  2. A Survey About Dental Instruments at the Primary Health Care in Brazil

    Joyce Lopes, Andréa Clemente Palmier, Marcos Azeredo Furquim Werneck e mais 2Brazilian Dental Journal2018citado por 2 artigos

    Abstract This study describes the structure of oral health services in primary health care in Brazil and the instruments available for the provision of oral health care and to compare the number of instruments according to organizational characteristics of health services and among the macroregions. Of the 23,251 oral…

  3. Comparative evaluation of Dual Gracey™ curettes and sonic instruments for deposit removal in molar furcations: an in vitro study

    Felipe BITTARELLO, Milena de Moura GIRARDELLO, Ana Laura Rosa SANTOS e mais 2Revista de Odontologia da UNESP2026

    Abstract Introduction The anatomical complexity of molar furcations challenges root deposit removal and may influence the effectiveness of periodontal instrumentation. Objective To evaluate the removal of simulated deposits in molar furcations using Dual Gracey™ curettes and sonic instruments. Material and method…

  4. Evaluation of the apical seal after intraradicular retainer removal with ultrasound or carbide bur

    Tomie Nakakuki Campos, Cleber Henrique Inoue, Elcio Yamamoto e mais 3Brazilian Oral Research2007

    There are situations in which intraradicular retainers have to be removed and replaced. The objective of this research was to evaluate the apical seal after the removal of a custom cast post and core with a carbide bur or with an ultrasound apparatus. Twenty five roots of extracted human incisors were used. They were…

  5. Cervical shaping in curved root canals: comparison of the efficiency of two endodontic instruments

    Sandra Soares Kühne Busquim e Marcelo dos SantosPesquisa Odontológica Brasileira2002citado por 2 artigos

    The aim of this study was to determine the removal of dentin produced by number 25 (0.08) Flare files (Quantec Flare Series, Analytic Endodontics, Glendora, California, USA) and number 1 e 2 Gates-Glidden burs (Dentsply - Maillefer, Ballaigues, Switzerland), in the mesio-buccal and mesio-lingual root canals…

  6. Debridement ability of the WaveOne Gold and TruNatomy systems in the apical third of root canals: ex vivo assessment

    Sara Carvalho Avelar de Oliveira, Carlos Eduardo da Silveira Bueno, Rina Andréa Pelegrine e mais 3Brazilian Dental Journal2024

    Abstract Cleaning and shaping the root canal system are essential steps for performing successful endodontic therapy, and are challenging procedures in the apical region. This study aimed to conduct an ex vivo assessment of the debridement ability of the WaveOne Gold (Medium 35/.06) and TruNatomy (Medium 36/.03)…

  7. Assessment of geometrical characteristics of dental endodontic micro-instruments utilizing X-ray micro computed tomography

    Youssef S. Al Jabbari, Peter Tsakiridis, George Eliades e mais 2Journal of Applied Oral Science2012

    OBJECTIVE: The aim of this study was to quantify the surface area, volume and specific surface area of endodontic files employing quantitative X-ray micro computed tomography (mXCT). MATERIAL AND METHODS: Three sets (six files each) of the Flex-Master Ni-Ti system (Nº 20, 25 and 30, taper .04) were utilized in this…

  8. Influence of Hero Apical instruments on cleaning ovoid-shaped root canals

    Renato Interliche, Melissa Andréia Marchesan, Silvio Rocha Correa da Silva e mais 3Brazilian Oral Research2011citado por 2 artigos

    The cleaning capacity of Hero 642 nickel-titanium files, complemented by the Hero Apical instruments in flattened roots, was determined by histological analysis, considering the area of action of the instruments on the coronal walls and the presence of remaining debris. Twenty-four single-canal, human mandibular…

  9. Influence of voxel size on micro-CT analysis of debris after root canal preparation

    Jáder Camilo Pinto, Fernanda Ferrari Esteves Torres, Airton Oliveira Santos Junior e mais 3Brazilian Oral Research2021citado por 2 artigos

    Abstract: The aim of this study was to assess the influence of micro-computed tomography (micro-CT) voxel size on the evaluation of debris accumulation after passive ultrasonic irrigation (PUI) in curved root canals prepared with rotary nickel-titanium files. Mesial root canals (n = 24) of mandibular molars with…

  10. Procedural errors during root canal preparation using rotary NiTi instruments detected by periapical radiography and cone beam computed tomography

    Ana Helena Gonçalves de Alencar, Paul M. H Dummer, Henrique César Marçal Oliveira e mais 2Brazilian Dental Journal2010citado por 10 artigos

    This study detected procedural errors created by rotary nickel-titanium (NiTi) instruments during root canal preparation by two imaging methods. Forty extracted human maxillary and mandibular molars were divided randomly into two groups and treated by two endodontists (n=10) and two undergraduate dental students…

  11. Micro-CT evaluation of apical enlargement of molar root canals using rotary or reciprocating heat-treated NiTi instruments

    Jáder Camilo PINTO, Mariana Mena Barreto PIVOTO-JOÃO, Camila Galetti ESPIR e mais 3Journal of Applied Oral Science2019citado por 5 artigos

    Abstract Objective The aim of this study was to evaluate the root canal preparation and apical enlargement of molar root canals with rotary or reciprocating heat-treated nickel-titanium (NiTi) instruments, by using micro-computed tomography (micro-CT). Methodology Mesial root canals (n=48) of mandibular molars, with a…

  12. Scanning electron microscopic and profilometric study of different sharpening stones

    Roberto Antonio Andrade Acevedo, Ana Karina Veloso Cardozo e José Eduardo César SampaioBrazilian Dental Journal2006

    Scaling and root planing contribute to the recovery of periodontal health. All periodontal instruments loose their fine cutting angle after use. To maintain this angle, correct sharpening is required using specifically designed stones. The characteristics of sharpening stones can be compared to the blade of the…

  13. Influence of heat treatment on color and flexibility of nickel-titanium endodontic instruments

    Bernardo Corrêa de ALMEIDA e Carlos Nelson ELIASRGO - Revista Gaúcha de Odontologia2020

    ABSTRACT Objective The aim of this study was to evaluate and compare the effect of heat treatment at different temperatures on the color and flexibility of nickel-titanium endodontic instruments. Methods Thirty-six nickel-titanium K-file endodontic instruments were divided into six groups and submitted to heat…

  14. Effect of different torques in cyclic fatigue resistance of K3 rotary instruments

    Dirce Akemi Sacaguti Kawakami, George Táccio de Miranda Candeiro, Eduardo Akisue e mais 2Brazilian Journal of Oral Sciences2015

    Aim: To assess the effect of different torque values on cyclic fatigue resistance of K3 rotary nickel-titanium (NiTi) files. Methods: Eighty K3 files, size 25 mm, taper 0.04 were divided in 4 groups according to different torques (0.5, 1, 2 and 6 Ncm) and were submitted to a cyclic fatigue test. This test was…

  15. A comparison of two reciprocating instruments using bending stress and cyclic fatigue tests

    Pantaleo SCELZA, DAVIDOWICZ Harry, Licinio Esmeraldo da SILVA e mais 2Brazilian Oral Research2015citado por 3 artigos

    The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) 25-08 and Reciproc (VDW, Munich, Germany) 25-08 instruments. A total of 60 nickel-titanium (NiTi) instruments…

  16. Torsional fatigue strength of reciprocating and rotary pathfinding instruments manufactured from different NiTi alloys

    Rodrigo Ricci VIVAN, Murilo Priori ALCALDE, George CANDEIRO e mais 3Brazilian Oral Research2019citado por 2 artigos

    Abstract To evaluate the torsional properties of engine-driven pathfinding instruments manufactured from different NiTi alloys – R-Pilot (tip size 12.5;.04 taper; M-Wire) and One G (tip size 14;.03 taper; Conventional NiTi). A total of 40 NiTi instruments from engine-driven pathfinding instruments (n = 20) were used…

  17. Effect of nickel-titanium alloys on root canal preparation and on mechanical properties of rotary instruments

    Rodrigo Ricci VIVAN, Vanessa Abreu Sanches Marques COSTA, Leticia Citelli CONTI e mais 5Brazilian Oral Research2022citado por 1 artigo

    Abstract The aim of this study was to evaluate the quality of curved root canal preparation, torsional fatigue, and cyclic fatigue of rotary systems manufactured with different NiTi alloys. Ninety single-rooted canals with curvatures of 15° to 30o were scanned and divided into three groups according to the rotary…

  18. Using manual versus mechanized glide path instruments and ProTaper Gold versus ProTaper Next systems in curved canals: micro-CT study

    Breno Nappi VENTURA, Giulio GAVINI, Elaine Faga IGLECIAS e mais 2Brazilian Oral Research2024

    Abstract The aim of this study was to evaluate the root canal shaping effect of ProTaper Gold (PTG) versus ProTaper Next (PTN) instrumentation systems, and of a manual #15 K-type file (K15) versus the ProGlider (PG) mechanized instrument for glide path creation, in severely curved mesial canals. Twenty-four mandibular…

  19. Cyclic fatigue resistance of novel Genius and Edgefile nickel-titanium reciprocating instruments

    Carlos Roberto Emerenciano Bueno, Marina Tolomei Sandoval Cury, Ana Maria Veiga Vasques e mais 5Brazilian Oral Research2019

    Abstract: This study aimed to assess the cyclic fatigue resistance of Genius and EdgeFile X1 reciprocating instruments compared with WaveOne Gold Primary. Twenty Genius (Ultradent) 25.04, 20 Genius 30.04, 20 EdgeFile X1 (EdgeEndo) and 20 WaveOne Gold Primary (Dentsply Maillefer) instruments were included in this study…

  20. Cyclic flexural fatigue resistance of NiTi Controlled Memory and Blue Technology instruments after torsional preloading

    Túlio César MODESTO, Eufemia Carolina Peláez ACOSTA, Pedro Damas RESENDE e mais 4Journal of Applied Oral Science2018

    Abstract Objective The aim of this study was to evaluate the influence of torsional preloading on the cyclic flexural fatigue resistance of thermally treated NiTi instruments. Material and Methods Ten new instruments New Hyflex CM (HF 30.06; Coltene/Whaladent Inc.), Typhoon CM (TYP 30.06; Clinician's Choice Dental…