Brazilian Oral Research2024

Using manual versus mechanized glide path instruments and ProTaper Gold versus ProTaper Next systems in curved canals: micro-CT study

Breno Nappi VENTURA, Giulio GAVINI, Elaine Faga IGLECIAS, Laila Gonzales FREIRE e Celso Luiz CALDEIRA

em inglês

cita 40 obras, 1 no acervo

resumo

Abstract The aim of this study was to evaluate the root canal shaping effect of ProTaper Gold (PTG) versus ProTaper Next (PTN) instrumentation systems, and of a manual #15 K-type file (K15) versus the ProGlider (PG) mechanized instrument for glide path creation, in severely curved mesial canals. Twenty-four mandibular molars with two separate mesial canals were anatomically matched using computed tomographic scanning, and then divided into two groups (n=12) according to the glide path instrument used, either K15 or PG. In all teeth, the PTG system was used to prepare the mesiobuccal canal, and the PTN, the mesiolingual canal. The teeth were scanned by computed microtomography, before and after root canal preparation, and the values of the initial volume, final volume, volumetric variation, untouched walls, and canal transportation variables were determined. The data were analyzed using the two-way ANOVA test, and the Tukey test for multiple comparisons. There was no significant difference among the study groups regarding volumetric variation or root canal transportation, either in the cervical, middle or apical thirds, or in the entire root canal (p>0.05). In the apical third, the percentage of untouched walls was significantly higher in groups using K15 than in those using PG (p<0.05), namely 33.144% and 23.285%, respectively, irrespective of the instrumentation system. In the other regions, there was no difference between K15 and PG regarding this variable. It was concluded that PG was associated with a lower rate of untouched walls in the apical region than K15.

como citar · ABNT NBR 6023

VENTURA, Breno Nappi et al. Using manual versus mechanized glide path instruments and ProTaper Gold versus ProTaper Next systems in curved canals: micro-CT study. Brazilian Oral Research, 2024. DOI: 10.1590/1807-3107BOR-2024.VOL38.0006.

Referências

40 obras citadas · 1 no acervo

  1. 1E Schäfer e S Bürklein. Impact of nickel-titanium instrumentation of the root canal on clinical outcomes: a focused review. Odontology, 2012quem mais cita →
  2. 2G Gavini, MD Santos, CL Caldeira e mais 3. Nickel-titanium instruments in endodontics: a concise review of the state of the art. Braz Oral Res, 2018no acervo →
  3. 3J Zupanc, N Vahdat-Pajouh e E Schäfer. New thermomechanically treated NiTi alloys - a review. Int Endod J, 2018quem mais cita →
  4. 4J Gagliardi, MA Versiani, MD Sousa Neto e mais 2. Evaluation of the shaping characteristics of ProTaper Gold, ProTaper NEXT, and ProTaper Universal in curved canals. J Endod, 2015quem mais cita →
  5. 5E Kosti, S Zinelis, I Molyvdas e mais 1. Effect of root canal curvature on the failure incidence of ProFile rotary Ni-Ti endodontic instruments. Int Endod J, 2011quem mais cita →
  6. 6C Kobayashi, T Yoshioka e H Suda. A new engine-driven canal preparation system with electronic canal measuring capability. J Endod, 1997quem mais cita →
  7. 7OA Peters, CI Peters, K Schönenberger e mais 1. ProTaper rotary root canal preparation: assessment of torque and force in relation to canal anatomy. Int Endod J, 2003quem mais cita →
  8. 8D Al Raeesi, SW Kwak, JH Ha e mais 3. Mechanical properties of glide path preparation instruments with different pitch lengths. J Endod, 2018quem mais cita →
  9. 9G Plotino, V Nagendrababu, F Bukiet e mais 3. Influence of negotiation, glide path, and preflaring procedures on root canal shaping - terminology, basic concepts, and a systematic review. J Endod, 2020quem mais cita →
  10. 10F Paqué, F Barbakow e OA Peters. Root canal preparation with Endo-Eze AET: changes in root canal shape assessed by micro-computed tomography. Int Endod J, 2005quem mais cita →
  11. 11ZU Aydın, NB Keskin, T Özyürek e mais 3. Microcomputed assessment of transportation, centering ratio, canal area, and volume increase after single-file rotary and reciprocating glide path instrumentation in curved root canals: a laboratory study. J Endod, 2019quem mais cita →
  12. 12JN Martins, EJ Silva, D Marques e mais 3. Evaluation of design, metallurgy, microhardness, and mechanical properties of glide path instruments: a multimethod approach. J Endod, 2021quem mais cita →
  13. 13ID Capar, H Ertas, E Ok e mais 2. Comparative study of different novel nickel-titanium rotary systems for root canal preparation in severely curved root canals. J Endod, 2014quem mais cita →
  14. 14SM Hasheminia, A Farhad, M Sheikhi e mais 3. Cone-beam computed tomographic analysis of canal transportation and centering ability of single-file systems. J Endod, 2018quem mais cita →
  15. 15J Pacheco-Yanes, I Gazzaneo, AR Pérez e mais 2. Transportation assessment in artificial curved canals after instrumentation with Reciproc, Reciproc Blue, and XP-endo Shaper Systems. J Investig Clin Dent, 2019quem mais cita →
  16. 16A Poly, F AlMalki, F Marques e mais 1. Canal transportation and centering ratio after preparation in severely curved canals: analysis by micro-computed tomography and double-digital radiography. Clin Oral Investig, 2019quem mais cita →
  17. 17PO Fernandes, LG Freire, EF Iglecias e mais 3. Assessment of mechanical root canal preparation with centric reciprocating or eccentric rotary kinematics: a micro-computed tomographic study. J Endod, 2020quem mais cita →
  18. 18C Zanesco, MV Só, S Schmidt e mais 3. Apical transportation, centering ratio, and volume increase after manual, rotary, and reciprocating instrumentation in curved root canals: analysis by micro-computed tomographic and digital subtraction radiography. J Endod, 2017quem mais cita →
  19. 19M Vorster, PJ van der Vyver e F Paleker. Canal transportation and centering ability of WaveOne Gold in combination with and without different glide path techniques. J Endod, 2018quem mais cita →
  20. 20PJ van der Vyver, F Paleker, M Vorster e mais 1. Micro-computed tomographic evaluation of two single rotary glide path systems. Int Endod J, 2019quem mais cita →
1–20 de 40 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações