Research on Biomedical Engineering2017

Enhancing quality in Diffusion Tensor Imaging with anisotropic anomalous diffusion filter

Antonio Carlos da Silva Senra Filho, Carlos Ernesto Garrido Salmon, Antonio Carlos dos Santos e Luiz Otávio Murta Junior

em inglês

cita 40 obras

resumo

Abstract Introduction: Diffusion tensor imaging (DTI) is an important medical imaging modality that has been useful to the study of microstructural changes in neurological diseases. However, the image noise level is a major practical limitation, in which one simple solution could be the average signal from a sequential acquisition. Nevertheless, this approach is time-consuming and is not often applied in the clinical routine. In this study, we aim to evaluate the anisotropic anomalous diffusion (AAD) filter in order to improve the general image quality of DTI. Methods A group of 20 healthy subjects with DTI data acquired (3T MR scanner) with different numbers of averages (N=1,2,4,6,8, and 16), where they were submitted to 2-D AAD and conventional anisotropic diffusion filters. The Relative Mean Error (RME), Structural Similarity Index (SSIM), Coefficient of Variation (CV) and tractography reconstruction were evaluated on Fractional Anisotropy (FA) and Apparent Diffusion Coefficient (ADC) maps. Results The results point to an improvement of up to 30% of CV, RME, and SSIM for the AAD filter, while up to 14% was found for the conventional AD filter (p<0.05). The tractography revealed a better estimative in fiber counting, where the AAD filter resulted in less FA variability. Furthermore, the AAD filter showed a quality improvement similar to a higher average approach, i.e. achieving an image quality equivalent to what was seen in two additional acquisitions. Conclusions In general, the AAD filter showed robustness in noise attenuation and global image quality improvement even in DTI images with high noise level.

como citar · ABNT NBR 6023

SENRA FILHO, Antonio Carlos da Silva et al. Enhancing quality in Diffusion Tensor Imaging with anisotropic anomalous diffusion filter. Research on Biomedical Engineering, 2017. DOI: 10.1590/2446-4740.02017.

Referências

40 obras citadas

  1. 1S Aja-Fernandez, M Niethammer, M Kubicki e mais 2. Restoration of DWI data using a Rician LMMSE estimator. IEEE Transactions on Medical Imaging, 2008quem mais cita →
  2. 2AL Alexander, JE Lee, M Lazar e mais 1. Diffusion tensor imaging of the brain. Neurotherapeutics; the Journal of the American Society for Experimental NeuroTherapeutics, 2007quem mais cita →
  3. 3J Bai e X-C Feng. Fractional-order anisotropic diffusion for image denoising. IEEE Transactions on Image Processing, 2007quem mais cita →
  4. 4S Basu, T Fletcher e R Whitaker. Rician noise removal in diffusion tensor MRI. Lecture Notes in Computer Science, 2006quem mais cita →
  5. 5R Boer, HA Vrooman, F van der Lijn e mais 5. White matter lesion extension to automatic brain tissue segmentation on MRI. NeuroImage, 2009quem mais cita →
  6. 6E Bullmore, A Barnes, DS Bassett e mais 4. Generic aspects of complexity in brain imaging data and other biological systems. NeuroImage, 2009quem mais cita →
  7. 7B Chen e EW Hsu. Noise removal in magnetic resonance diffusion tensor imaging. Magnetic Resonance in Medicine, 2005quem mais cita →
  8. 8O Christiansen, T-M Lee, J Lie e mais 2. Total variation regularization of matrix-valued images. International Journal of Biomedical Imaging, 2007quem mais cita →
  9. 9RC Gonzalez e RE Woods. Digital Image Processing. 2008quem mais cita →
  10. 10M Jenkinson, CF Beckmann, TEJ Behrens e mais 2. FSL. NeuroImage, 2012
  11. 11VG Kiselev, KR Hahn e DP Auer. Is the brain cortex a fractal?. NeuroImage, 2003quem mais cita →
  12. 12JE Lee, MK Chung e AL Alexander. Evaluation of anisotropic filters for diffusion tensor imaging. 2006quem mais cita →
  13. 13W Lin e C-C Jay Kuo. Perceptual visual quality metrics: a survey. Journal of Visual Communication and Image Representation, 2011quem mais cita →
  14. 14J Ling e AC Bovik. Smoothing low-SNR molecular images via anisotropic median-diffusion. IEEE Transactions on Medical Imaging, 2002quem mais cita →
  15. 15L Malacarne, R Mendes, I Pedron e mais 1. Nonlinear equation for anomalous diffusion: unified power-law and stretched exponential exact solution. Physical Review E: Statistical, Nonlinear, and Soft Matter Physics, 2001quem mais cita →
  16. 16JV Manjón, J Carbonell-Caballero, JJ Lull e mais 3. MRI denoising using Non-Local Means. Medical Image Analysis, 2008quem mais cita →
  17. 17M Martin-Fernandez, E Munoz-Moreno, L Cammoun e mais 3. Sequential anisotropic multichannel Wiener filtering with Rician bias correction applied to 3D regularization of DWI data. Medical Image Analysis, 2009quem mais cita →
  18. 18II Maximov, E Farrher, F Grinberg e mais 1. Spatially variable Rician noise in magnetic resonance imaging. Medical Image Analysis, 2012quem mais cita →
  19. 19T McGraw, BC Vemuri, Y Chen e mais 2. DT-MRI denoising and neuronal fiber tracking. Medical Image Analysis, 2004quem mais cita →
  20. 20M Moraschi, GE Hagberg, M Di Paola e mais 3. Smoothing that does not blur: effects of the anisotropic approach for evaluating diffusion tensor imaging data in the clinic. Journal of Magnetic Resonance Imaging, 2010quem mais cita →
1–20 de 40 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações