Abstract: Introduction Diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) combine magnetic resonance imaging (MRI) techniques and diffusion measures. In DWI, the contrast is defined by microscopic motion of water protons. Nowadays, DWI has become important for early diagnostic of acute stroke. DTI images are calculated from DWI images acquired in at least six directions, which give information of diffusion directionality, making it possible to reconstruct axonal or muscle fiber images. Both techniques have been applied to study body structures in healthy and pathological conditions. Currently, it is known that these images and derived parameters are quite sensitive to factors related to acquisition and processing. Magnetic field inhomogeneity, susceptibility, chemical shift, radiofrequency (RF) interference, eddy currents and low signal-to-noise ratio (SNR) can have a more harmful effect in diffusion data than in T1- or T2-weighted image data. However, even today there are not reference phantoms and guidelines for DWI or DTI quality control (QC). Review Proposals for construction and use of DWI and DTI QC phantoms can be found in literature. DWI have been evaluated using containers filled by gel or liquid with tissue-like MRI properties, as well as using microfabricated devices. DTI acquisitions also have been checked with these devices or using natural or artificial fiber structures. The head phantom from American College of Radiology (ACR) is also pointed out as an alternative for DTI QC. This article brings a discussion about proposed DWI and DTI phantoms, challenges involved and future perspectives for standardization of DWI and DTI QC.

como citar · ABNT NBR 6023

SOUZA, Edna Marina de; COSTA, Eduardo Tavares; CASTELLANO, Gabriela. Phantoms for diffusion-weighted imaging and diffusion tensor imaging quality control: a review and new perspectives. Research on Biomedical Engineering, 2017. DOI: 10.1590/2446-4740.07816.

Referências

33 obras citadas

  1. 1R Bammer. Basic principles of diffusion-weighted imaging. European Journal of Radiology, 2003quem mais cita →
  2. 2P Basser. New histological and physiological stains derived from diffusion-tensor MR images. Annals of the New York Academy of Sciences, 1997quem mais cita →
  3. 3JA Bell, CE Saikus, K Ratnayaka e mais 6. A deflectable guiding catheter for real-time MRI-guided interventions. Journal of Magnetic Resonance Imaging, 2012quem mais cita →
  4. 4T Boursianis, G Kalaitzakis, S Veneti e mais 3. MRI Diffusion measurements on phantoms: comparison between EPI and HASTE sequences utilizing two fitting methods in Apparent Diffusion Coefficient (ADC) measurements. Physica Medica, 2014quem mais cita →
  5. 5J-F Budzik, V Balbi, S Verclytte e mais 3. Diffusion tensor imaging in musculoskeletal disorders. Radiographics, 2014quem mais cita →
  6. 6H Chen, Y Zhao, T Zhang e mais 5. Construct and assess multimodal mouse brain connectomes via joint modeling of multi-scale DTI and neuron tracer data. Med Image Comput Comput Assist Interv., 2014quem mais cita →
  7. 7B Ebrahimi, SD Swanson e TE Chupp. A microfabricated phantom for quantitative MR perfusion measurements: validation of singular value decomposition deconvolution method. IEEE Transactions on Biomedical Engineering, 2010quem mais cita →
  8. 8E Fieremans, Y De Deene, S Delputte e mais 6. Simulation and experimental verification of the diffusion in an anisotropic fiber phantom. Journal of Magnetic Resonance, 2008quem mais cita →
  9. 9S Gatidis, H Schmidt, P Martirosian e mais 1. Development of an MRI phantom for diffusion-weighted imaging with independent adjustment of apparent diffusion coefficient values and T2 relaxation times. Magnetic Resonance in Medicine, 2014quem mais cita →
  10. 10A Hellerbach, V Schuster, A Jansen e mais 1. MRI phantoms: are there alternatives to agar?. PLoS One, 2013quem mais cita →
  11. 11PL Hubbard, FL Zhou, SJ Eichhorn e mais 1. Biomimetic phantom for the validation of diffusion magnetic resonance imaging. Magnetic Resonance in Medicine, 2015quem mais cita →
  12. 12H Kato, M Kuroda, K Yoshimura e mais 5. Composition of MRI phantom equivalent to human tissues. Medical Physics, 2005quem mais cita →
  13. 13SJ Kim, CG Choi, JK Kim e mais 4. Effects of MR parameter changes on the quantification of diffusion anisotropy and apparent diffusion coefficient in diffusion tensor imaging: evaluation using a diffusional anisotropic phantom. Korean Journal of Radiology, 2015quem mais cita →
  14. 14ME Komlosh, MJ Lizak, F Horkay e mais 2. Observation of microscopic diffusion anisotropy in the spinal cord using double-pulsed gradient spin echo MRI. Magnetic Resonance in Medicine, 2008quem mais cita →
  15. 15ME Komlosh, E Ozarslan, MJ Lizak e mais 5. Pore diameter mapping using double pulsed-field gradient MRI and its validation using a novel glass capillary array phantom. Journal of Magnetic Resonance, 2011quem mais cita →
  16. 16J Latt, M Nilsson, A Rydhog e mais 3. Effects of restricted diffusion in a biological phantom: A q-space diffusion MRI study of asparagus stems at a 3T clinical scanner. Magma, 2007quem mais cita →
  17. 17HJ Laubach, PM Jakob, KO Loevblad e mais 4. A phantom for diffusion-weighted imaging of acute stroke. Journal of Magnetic Resonance Imaging, 1998quem mais cita →
  18. 18I Lavdas, KC Behan, A Papadaki e mais 2. A phantom for diffusion-weighted MRI (DW-MRI). Journal of Magnetic Resonance Imaging, 2013quem mais cita →
  19. 19I Lavdas, ME Miquel, DW McRobbie e mais 1. Comparison between diffusion-weighted MRI (DW-MRI) at 1.5 and 3 tesla: a phantom study. Journal of Magnetic Resonance Imaging, 2014quem mais cita →
  20. 20D Le Bihan, C Poupon, A Amadon e mais 1. Artifacts and pitfalls in diffusion MRI. Journal of Magnetic Resonance Imaging, 2006quem mais cita →
1–20 de 33 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações