Guided vs. conventional surgery for anterior maxillary implants: does experience still matter? – An in vitro study
Tatiana Cursino PEREIRA, Aline Lopes GARBIM, Michelle Bianchi de MORAES, Fernando Vagner ARALDI, Guilherme de Siqueira Ferreira Anzaloni SAAVEDRA e Rodrigo Dias NASCIMENTO
em inglês
resumo
ABSTRACT Objective To evaluate the accuracy of immediate implant placement in the anterior maxilla, comparing guided and conventional surgical methods according to operator expertise. Material and Methods Twenty operators participated: ten used guided techniques and ten used conventional approaches, all in the region of teeth 12 and 22. Cases were randomly assigned to four groups: experienced–guided (EG), experienced–conventional (EC), inexperienced–guided (IG), and inexperienced–conventional (IC), with ten implants in each group (40 implants total). Standardized training models were scanned with cone beam computed tomography (CBCT) for virtual planning and surgical guide fabrication using coDiagnostiX® software. After implant placement, new CBCT scans were obtained. Virtual planning and postoperative scans were superimposed to assess accuracy, measuring global (3D), angular, and linear deviations in mesiodistal (MD), buccolingual (BL), and apicocoronal (AC) dimensions. Results Among experienced operators, guided surgery showed significantly lower angular and linear deviations at the platform and apex in 3D, MD, and BL measurements. In inexperienced operators, similar advantages were observed for guided surgery in BL and in 3D and MD deviations at the apex. Overall, guided surgery consistently achieved greater accuracy, regardless of operator experience. Conclusion Guided surgery demonstrated greater accuracy than conventional surgery for immediate implant placement in the anterior maxilla, regardless of operator experience, highlighting its potential to enhance surgical precision and clinical outcomes.
como citar · ABNT NBR 6023
PEREIRA, Tatiana Cursino et al. Guided vs. conventional surgery for anterior maxillary implants: does experience still matter? – An in vitro study. Brazilian Dental Science, 2026. DOI: 10.4322/BDS.2026.E5181.
Referências
15 obras citadas
- 1E Chrabieh, C Hanna, S Mrad e mais 3. Accuracy of computer-guided implant surgery in partially edentulous patients: a prospective observational study. Int J Implant Dent, 2024quem mais cita →
- 2TC Pereira, F Godoy, D Cunha e mais 2. How reverse planning and the use of digital devices revolutionize implantology? – Case report. Braz Dent Sci, 2024quem mais cita →
- 3RE Matta, B Bergauer, W Adler e mais 2. The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template. J Craniomaxillofac Surg, 2017quem mais cita →
- 4P Kiatkroekkrai, C Takolpuckdee, K Subbalekha e mais 2. Accuracy of implant position when placed using static computer-assisted implant surgical guides manufactured with two different optical scanning techniques: a randomized clinical trial. International Journal of Oral and Maxillofacial Surgery, 2020quem mais cita →
- 5J Abduo e D Lau. Accuracy of static computer-assisted implant placement in anterior and posterior sites by clinicians new to implant dentistry: in vitro comparison of fully guided, pilot-guided, and freehand protocols. Int J Implant Dent, 2020quem mais cita →
- 6P Smitkarn, K Subbalekha, N Mattheos e mais 1. The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery. J Clin Periodontol, 2019quem mais cita →
- 7F Bover-Ramos, J Viña-Almunia, J Cervera-Ballester e mais 2. Accuracy of implant placement with computer-guided surgery: a systematic review and meta-analysis comparing cadaver, clinical, and in vitro studies. Int J Oral Maxillofac Implants, 2018quem mais cita →
- 8M Vercruyssen, M Hultin, N van Assche e mais 3. Guided surgery: accuracy and efficacy. Periodontol 2000, 2014quem mais cita →
- 9RM Cunha, FÁ Souza, H Hadad e mais 3. Accuracy evaluation of computer-guided implant surgery associated with prototyped surgical guides. J Prosthet Dent, 2021quem mais cita →
- 10D Schneider, C Sax, M Sancho-Puchades e mais 2. Accuracy of computer-assisted, template-guided implant placement compared with conventional implant placement by hand-An in vitro study. Clin Oral Implants Res, 2021quem mais cita →
- 11K Søndergaard, M Hosseini, S Storgård Jensen e mais 2. Fully versus conventionally guided implant placement by dental students: A randomized controlled trial. Clin Oral Implants Res, 2021quem mais cita →
- 12M Cassetta e M Bellardini. How much does experience in guided implant surgery play a role in accuracy? A randomized controlled pilot study. International Journal of Oral and Maxillofacial Surgery, 2017quem mais cita →
- 13Z Chen, J Li, K Sinjab e mais 3. Accuracy of flapless immediate implant placement in anterior maxilla using computer-assisted versus freehand surgery: a cadaver study. Clin Oral Implants Res, 2018quem mais cita →
- 14K Rungcharassaeng, JM Caruso, JY Kan e mais 2. Accuracy of computer-guided surgery: A comparison of operator experience. J Prosthet Dent, 2015quem mais cita →
- 15NO Miranda, LM Dos Anjos, AO Rocha e mais 3. Global research interest and publication trends on guided surgery in implant dentistry: A metrics-based analysis. J Prosthet Dent, 2025quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda