Abstract Computer-guided surgery, which combines tomographic data and digital models, has been widely used in implant dentistry to improve implant placement accuracy. Objective: This in vitro study evaluated the accuracy of virtual planning for single implant placement in the regions of teeth 33 and 43, comparing bone-supported and mucosa-supported guides. A secondary analysis assessed differences related to insertion method, since implant placement in the 43 region used a manual ratchet and in the 33 region used a motorized handpiece. Methodology: In total, 32 implants were placed in 16 edentulous artificial mandibles (8 using bone-supported guides and 8 using mucosa-supported guides), with two implants per mandible. Implant positions were assessed using computed tomography and compared with the virtual plan using ImageJ (2.16.0/1.54p) and OneViewerApp (version 1.18.0.0, 2023). Statistical analysis was performed on Jamovi (p<0.05). Linear deviations between the planned and actual implant placement were compared using t-test or the Mann-Whitney U test, depending on data distribution. Results: Results indicated greater deviations for mucosa-supported guides, especially in the buccolingual direction, whereas bone-supported guides exhibited greater accuracy. Conclusion: Within the limitations of this in vitro study, the type of guide support may influence implant placement accuracy and should be carefully considered, particularly in procedures requiring high precision. Further studies are needed to confirm these findings in clinical settings.

como citar · ABNT NBR 6023

RIBEIRO, Ana Maria Alves; SEIXAS, Déborah Rocha; GONÇALES, Eduardo Sanches. Implant placement accuracy using computer-guided surgical templates supported by bone and mucosa: an in vitro study. Journal of Applied Oral Science, 2026. DOI: 10.1590/1678-7765-2025-0926.

Referências

18 obras citadas

  1. 1F Bover-Ramos, J Viña-Almunia, J Cervera-Ballester e mais 2. Accuracy of implant placement with computer-guided surgery: a systematic review and meta-analysis comparing cadaver, clinical, and in vitro studies. Int J Oral Maxillofac Implants, 2018quem mais cita →
  2. 2M Azevedo, F Correia e R Faria Almeida. Accuracy of implant guided surgery in fully edentulous patients: prediction vs. actual outcome-systematic review. J Clin Med, 2024quem mais cita →
  3. 3C Seo e G Juodzbalys. Accuracy of guided surgery via stereolithographic mucosa-supported surgical guide in implant surgery for edentulous patient: a systematic review. J Oral Maxillofac Res, 2018quem mais cita →
  4. 4JG Deeb, S Bencharit, CA Loschiavo e mais 3. Do implant surgical guides allow an adequate zone of keratinized tissue for flapless surgery?. J Oral Maxillofac Surg, 2018quem mais cita →
  5. 5W Zhou, G Feng, Z Luo e mais 3. Comparison of the accuracy of guided implant surgery between two implant-planning software: a retrospective cohort study. Front Oral Health, 2025quem mais cita →
  6. 6M Markiewicz e AA Nowicki. Accuracy of computer-guided dental implant placement: a clinical comparison of three surgical guide types. J Clin Med, 2025quem mais cita →
  7. 7YN Raico Gallardo, IR Silva-Olivio, E Mukai e mais 3. Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta-analysis. Clin Oral Implants Res, 2017quem mais cita →
  8. 8R Alaqeely, A Albaiz, B Alenazi e mais 3. Prevalence of dental implant positioning errors: a radiographic analysis. J Clin Med, 2025quem mais cita →
  9. 9S Sadilina, K Vietor, R Doliveux e mais 3. Beyond accuracy: clinical outcomes of computer assisted implant surgery. Clin Exp Dent Res, 2025quem mais cita →
  10. 10B Ma, T Park, I Chun e mais 1. The accuracy of a 3D printing surgical guide determined by CBCT and model analysis. J Adv Prosthodont, 2018quem mais cita →
  11. 11J Krithikadatta, V Gopikrishna e M Datta. CRIS guidelines (Checklist for Reporting In-vitro Studies): a concept note on the need for standardized guidelines for improving quality and transparency in reporting in-vitro studies in experimental dental research. J Conserv Dent, 2014quem mais cita →
  12. 12SS Taheri Otaghsara, T Joda e FM Thieringer. Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: an in vitro study. J Dent, 2023quem mais cita →
  13. 13R D'haese, T Vrombaut, G Hommez e mais 2. Accuracy of guided implant surgery in the edentulous jaw using desktop 3D-printed mucosal supported guides. J Clin Med, 2021quem mais cita →
  14. 14K Orban, E Varga, P Windisch e mais 2. Accuracy of half-guided implant placement with machine-driven or manual insertion: a prospective, randomized clinical study. Clin Oral Investig, 2022quem mais cita →
  15. 15N Marquez Bautista, C Meniz-García, C López-Carriches e mais 3. Accuracy of different systems of guided implant surgery and methods for quantification: a systematic review. Appl Sci (Basel), 2024quem mais cita →
  16. 16Y Shi, J Wang, C Ma e mais 3. A systematic review of the accuracy of digital surgical guides for dental implantation. Int J Implant Dent, 2023quem mais cita →
  17. 17MC Schulz, L Rittmann, U Range e mais 2. The use of orientation templates and free-hand implant insertion in artificial mandibles: an experimental laboratory examination in fifth-year dental students. Dent J (Basel), 2018quem mais cita →
  18. 18R Bjelica, I Smojver, L Stojić e mais 3. Accuracy of fully guided implant placement using bone-supported stackable surgical guides in completely edentulous patients: a retrospective study. J Clin Med, 2026quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações