Dental Press Journal of Orthodontics2022
Correlation between cortical bone thickness at mini-implant insertion sites and age of patient
Anna Carolina Teixeira CENTENO, Caroline Kolling FENSTERSEIFER, Vitória de Oliveira CHAMI, Eduardo Silveira FERREIRA, Mariana MARQUEZAN e Vilmar Antônio FERRAZZO
em inglês
resumo
ABSTRACT Introduction: Orthodontic mini-implants (MI) are a reliable alternative to provide temporary orthodontic anchorage. Prior to miniscrew insertion, the best approach would be to evaluate each possible insertion site and measure the cortical bone thickness, and verify whether it would provide adequate primary stability. Objective: This study aimed to evaluate the difference in cortical bone thickness in areas of mini-implants insertion in patients of different ages, by means of cone beam computed tomography (CBCT). Methods: The sample of this retrospective study was composed of 123 CBCT scans, which were used to measure cortical bone thickness in the buccal and palatal inter-radicular space in the mesial region of the first permanent molars. These measures were compared by using the Student’s t-test, ANOVA/Tukey tests, and Linear regression between male and female subjects, from 12 to 30 years old. Results: No significant difference was found in cortical bone thickness between sex, race and sagittal facial patterns. Significantly higher measurement values were observed in patients older than 12 years of age at all sites evaluated. The coefficient β at the adjusted linear regression analysis showed that at each increment in age, mean cortical thickness values increased by 0.06mm in the mandible, 0.03mm in the buccal region and 0.02mm in the palatal region of the maxilla. Conclusions: The increase in cortical bone thickness was positively associated with age; that is, the more advanced the patient’s age was, the less chance there was of failure due to primary stability.
como citar · ABNT NBR 6023
CENTENO, Anna Carolina Teixeira et al. Correlation between cortical bone thickness at mini-implant insertion sites and age of patient. Dental Press Journal of Orthodontics, 2022. DOI: 10.1590/2177-6709.27.1.E222098.OAR.
Referências
28 obras citadas
- 1MA Papadopoulos e F Tarawneh. The use of miniscrew implants for temporary skeletal anchorage in orthodontics a comprehensive review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2007quem mais cita →
- 2R Reynders, L Ronchi e S Bipat. Mini-implants in orthodontics: a systematic review of the literature. Am J Orthod Dentofacial Orthop, 2009quem mais cita →
- 3M Motoyoshi, M Uemura, A Ono e mais 3. Factors affecting the long-term stability of orthodontic mini-implants. Am J Orthod Dentofacial Orthop, 2010quem mais cita →
- 4B Wilmes, C Rademacher, G Olthoff e mais 1. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop, 2006quem mais cita →
- 5SJ Cheng, IY Tseng, JJ Lee e mais 1. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants, 2004quem mais cita →
- 6JW Freudenthaler, R Haas e HP Bantleon. Bicortical titanium screws for critical orthodontic anchorage in the mandible a preliminary report on clinical applications. Clin Oral Implants Res, 2001quem mais cita →
- 7P Trisi, W Rao e A Rebaudi. A histometric comparison of smooth and rough titanium implants in human low-density jawbone. Int J Oral Maxillofac Implants, 1999quem mais cita →
- 8M Migliorati, S Drago, I Schiavetti e mais 3. Orthodontic miniscrews an experimental campaign on primary stability and bone properties. Eur J Orthod, 2015quem mais cita →
- 9M Marquezan, CT Mattos, EF Sant'Anna e mais 2. Does cortical thickness influence the primary stability of miniscrews : a systematic review and meta-analysis. Angle Orthod, 2014quem mais cita →
- 10American Academy of Oral and Maxillofacial Radiology. Clinical recommendations regarding use of cone beam computed tomography in orthodontics [corrected]. Position statement by the American Academy of Oral and Maxillofacial Radiology. Oral Surg Oral Med Oral Pathol Oral Radiol, 2013quem mais cita →
- 11CC Steiner. Cephalometric in clinical practice. Angle Orthod, 1959quem mais cita →
- 12RM Ricketts, RH Roth, SJ Chaconas e mais 2. Bioprogressive technique of Ricketts. 1983quem mais cita →
- 13T Deguchi, M Nasu, K Murakami e mais 3. Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants. Am J Orthod Dentofacial Orthop, 2006quem mais cita →
- 14MA Schnelle, FM Beck, RM Jaynes e mais 1. A radiographic evaluation of the availability of bone for placement of miniscrews. Angle Orthod, 2004quem mais cita →
- 15WH Lim, SK Lee, UM Wikesjö e mais 1. A descriptive tissue evaluation at maxillary interradicular sites implications for orthodontic mini-implant placement. Clin Anat, 2007quem mais cita →
- 16J Antoszewska, MA Papadopoulos, HS Park e mais 1. Five-year experience with orthodontic miniscrew implants: a retrospective investigation of factors influencing success rates. Am J Orthod Dentofacial Orthop, 2009quem mais cita →
- 17F Javed e GE Romanos. The role of primary stability for successful immediate loading of dental implants A literature review. J Dent, 2010quem mais cita →
- 18MC Cehreli, D Karasoy, K Akca e mais 1. Meta-analysis of methods used to assess implant stability. Int J Oral Maxillofac Implants, 2009quem mais cita →
- 19CH Moon, HK Park, JS Nam e mais 2. Relationship between vertical skeletal pattern and success rate of orthodontic mini-implants. Am J Orthod Dentofacial Orthop, 2010quem mais cita →
- 20T Usui, S Uematsu, H Kanegae e mais 2. Change in maximum occlusal force in association with maxillofacial growth. Orthod Craniofac Res, 2007quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda