RGO - Revista Gaúcha de Odontologia2017
Immediate loading over lower prosthesis in edentulous mandibles: comparison between two types of prosthetic connection
Marina Reis OLIVEIRA, Ariane de Souza OLIVEIRA, Vitor Augusto LEITE, Marisa Aparecida Cabrini GABRIELLI, Oriana Elara Barelli PAGANELLI, Rubens SPIN-NETO e Valfrido Antonio PEREIRA-FILHO
em inglês
resumo
ABSTRACT Objective: This study evaluated two implant-abutment connection systems under immediate loading of lower prosthesis in edentulous mandibles. Methods: Seventy-two implants placed in 18 patients were analyzed. The parameters evaluated included probing depth, stability of implants and perimplant bone loss, which were measured immediately when installing the prosthesis and after 3 and 6 months. All data underwent statistical analysis (T-Test and ANOVA, 5% significance level). Results: Implants with Morse cone connections showed smaller, statistically significant probing depth values for all periods (0.68/1.19/1.31), when compared to the external hexagon connections (1.08/1.52/1.64). A statistically significant difference was observed between baseline, 3 months (p<0.01 for Morse cone; p<0.001 for external hexagon) and 6 months (p<0.001 for both connections). When periods were considered there was a statistically significant difference in Implant Stability Quotient ISQ values between baseline and 6 months for both prosthetic connections. Conclusion: Immediate loading of the lower prosthesis is a viable option for the treatment of edentulous mandibles and that the external hexagon or Morse cone connections do not interfere with the success of the implants in a short-term evaluation.
como citar · ABNT NBR 6023
OLIVEIRA, Marina Reis et al. Immediate loading over lower prosthesis in edentulous mandibles: comparison between two types of prosthetic connection. RGO - Revista Gaúcha de Odontologia, 2017. DOI: 10.1590/1981-863720170002000043369.
Referências
24 obras citadas
- 1BP Tonella, EP Pellizzer, R Ferraço e mais 3. Photoelastic analysis of cemented or screwed implant-supported prosthesis with different prothetic connections. J Oral Implantol, 2011quem mais cita →
- 2JMFK Takahashi, AC Dayrell, RLX Consani e mais 3. Stress evaluation of implant-abutment connections under different loading conditions a 3D finite element study. J Oral Implantol, 2015quem mais cita →
- 3MC Goiato, AA Pesqueira, RM Falcón-Antenucci e mais 3. Stress distribution in implant-supported prosthesis with external and internal implant-abutment connections. Acta Odontol Scand, 2013quem mais cita →
- 4M Rismanchian, F Bajoghli, T Gholamreza e mais 1. Dental implants early versus standard two-stage loading (Animal Study). J Oral Implantol, 2014quem mais cita →
- 5I Sanz-Sánchez, I Sanz-Martín, E Figuero e mais 1. Clinical efficacy of immediated implant loading protocols compared to conventional loading depending on the type of the restoration a systematic review. Clin Oral Impl Res, 2015quem mais cita →
- 6W Li, J Chow, E Hui e mais 2. Retrospective study on immediated functional loading of edentulous maxillas and mandibles with 690 implants up to 71 months of follow-up. J Oral Maxillofac Surg, 2009quem mais cita →
- 7P Streckbein, RG Streckbein, JF Wilbrand e mais 3. Non-linear 3D evaluation of different oral implant-abutment connections. J Dent Res, 2012quem mais cita →
- 8S Gracis, K Michalakis, P Vigolo e mais 3. Internal vs external connections for abutments reconstructions a systematic review. Clin Oral Impl Res, 2012quem mais cita →
- 9MI Lin, YW Shen, HL Huang e mais 2. A retrospective study of implant-abutment connections on crestal bone level. J Dent Res, 2013quem mais cita →
- 10KT Koo, EJ Lee, JY Kim e mais 3. The effect of internal versus external abutment connection modes on crestal bone changes around dental implants a radiographic analysis. J Periodontol, 2012quem mais cita →
- 11DAF Almeida, EP Pellizzer, FR Verri e mais 2. Influence of tapered and external hexagon connections on bone stresses around tilted dental implants three-dimensional finite element method with statistical analysis. J Periodontol, 2014quem mais cita →
- 12F Schwarz, A Hegewald e J Becker. Impact of implant-abutment connection and positioning of the machined collar/microgap on crestal bone level a systematic review. Clin Oral Impl Res, 2014quem mais cita →
- 13U Lekholm e G Zarb. Tissue integrated protheses. 1985quem mais cita →
- 14M Chiapasco, C Gatti, E Rossi e mais 2. Implant retained mandibular overdentures with imeediate loading A retrospective multicenter study on 226 consecutive cases. Clin Oral Impl Res, 1997quem mais cita →
- 15JA Gerber, WC Tan, TE Balmer e mais 2. Bleeding on probing and pocket probing depth in relation to probing pressure and mucosal health around oral implants. Clin Oral Impl Res, 2009quem mais cita →
- 16SM Heckmann, A Schrott, F Graef e mais 2. Mandibular two implants telescopic overdentures 10-year clinical and radiographical results. Clin Oral Impl Res, 2004quem mais cita →
- 17SA Gehke, MSS Viana e BA Dedavid. Influence of bone insersion level of the implant on the fracture strength of different connection designs an in vitro study. Clin Oral Invest, 2014quem mais cita →
- 18AS Gehke. Importance of crown height rations in dental implants on the fracture strenght of different connection designs an in vitro study. Clin Impl Relat Res, 2015quem mais cita →
- 19S D'ercole, A Scarano, V Perrotti e mais 3. Implants with internal hexagon and conical implant-abutment connections an in vitro study of the bacterial contamination. J Implantol, 2014quem mais cita →
- 20T Albrektsson, G Zarb, P Worthington e mais 1. The long-term efficacy of currently used dental implants a review and proposed criteria of success. Int J Oral Maxillofac Implants, 1986quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda