Revista Brasileira de Cineantropometria & Desempenho Humano2019
Correlation of body composition parameters using different methods among Brazilian obese adults
Lívia Santana Neves Máximo, Flávia Franca Melo, Lara Benigno Porto, Izabel Cristina Rodrigues da Silva, Mirley do Prado e Hermelinda Cordeiro Pedrosa
em inglês
resumo
Abstract Data comparing anthropometric measurements, bioelectrical impedance analysis (BIA) and dual-energy X-ray absortiometry (DXA) parameters are somehow limited and conflicting. The objective of this study was to correlate anthropometric, BIA and DXA parameters among obese Brazilian adults with focus on the comparison with visceral adipose tissue (VAT) obtained from DXA and in the value of antropometric measurements. Fifty voluntary participants were enrolled. The Spearman correlation test was used to assess the correlation of VAT with anthropometric measurements, BIA and other DXA parameters. The intra-class correlation coefficient (ICC) was used to evaluate concordance between lean mass (LM), fat mass (FM), %body fat (%BF) and %upper body fat (%UBF) obtained from BIA and DXA. Most were female (80%) and had an average body index mass (BMI) of 39.0 (± 6.4) kg/m2. The only anthropometric measurements showing a strong correlation with VAT were abdominal circumference (AC) and waist-to-height ratio (WHtR), but just in females. There was a very good correlation for LM [ICC = 0.951 (CI = 0.913 - 0.972)], FM [ICC = 0.987 (CI = 0.977 – 0.993)], %BF [ICC = 0.961 (CI = 0.931-0.978)], and %UBF [ICC = 0.873 (CI = 0.776 – 0.928)], between data collected through BIA and DXA. Among the anthropometric measurements assessed, only AC and WHtR seems to estimate patients with abdominal fat distribution and higher VAT in females. DXA and BIA proved similar for the evaluation of LM, FM, %BF and %UBF, although DXA has the advantage of estimating VAT.
como citar · ABNT NBR 6023
MÁXIMO, Lívia Santana Neves et al. Correlation of body composition parameters using different methods among Brazilian obese adults. Revista Brasileira de Cineantropometria & Desempenho Humano, 2019. DOI: 10.1590/1980-0037.2019V21E60539.
Referências
25 obras citadas
- 1WHO. Obesity: preventing and managing the global epidemic. Report of a WHO consultation. Technical Report Series, 2000quem mais cita →
- 2A Khan, S Raza e Y Khan. Current updates in the medical management of obesity. Recent Pat Endocr Metab Immune Drug Discov, 2012quem mais cita →
- 3Vigitel Brasil Saúde. Ministério da Saúde. 2016
- 4PT Katzmarzyk, FL Greenway, SB Heymsfield e mais 1. Clinical utility and reproducibility of visceral adipose tissue measurements derived from dual-energy X-ray absorptiometry in White and African American adults. Obesity (Silver Spring), 2013quem mais cita →
- 5S Kaul, MP Rothney, DM Peters e mais 3. Dual-energy x-ray absorptiometry for quantification of visceral fat. Obesity, 2012quem mais cita →
- 6BM Kaess, A Pedley, JM Massaro e mais 3. The ratio of visceral to subcutaneous fat, a metric of body fat distribution, is a unique correlate of cardiometabolic risk. Diabetologia, 2012quem mais cita →
- 7RV Shah, VL Murthy, SA Abbasi e mais 3. Visceral adiposity and the risk of metabolic syndrome across body mass index: The mesa study. JACC Cardiovasc Imaging, 2014quem mais cita →
- 8SY Lee e D Gallagher. Assessment methods in human body composition. Curr Opin Clin Nutr Metab Care, 2008quem mais cita →
- 9MØ Fosbøl e B Zerahn. Contemporary methods of body composition measurement. Clin Physiol Funct Imaging, 2015quem mais cita →
- 10T Lemos e D. Gallagher. Current body composition measurement techniques. Curr Opin Endocrinol Diabetes Obes, 2017quem mais cita →
- 11M Ashwell e S Gibson. Waist-to-height ratio as an indicator of 'early health risk': simpler and more predictive than using a 'matrix' based on BMI and waist circumference. BMJ Open, 2016quem mais cita →
- 12SL Faria, OP Faria, MDA Cardeal e mais 1. Validation study of multi-frequency bioelectrical impedance with dual energy x-ray absoptiometry among obese patients. Obes Surg, 2014quem mais cita →
- 13YC Li, CI Li, WY Lin e mais 3. Percentage of body fat assessment using bioelectrical impedance analysis and dual-energy X-ray absorptiometry in a weight loss program for obese or overweight Chinese adults. PLoS One, 2013quem mais cita →
- 14IJ Neeland, SM Grundy, X Li e mais 2. Comparison of visceral fat mass measurement by dual-X-ray absorptiometry and magnetic resonance imaging in a multiethnic cohort: the Dallas Heart Study. Nutr Diabetes, 2016quem mais cita →
- 15F Buckinx, JY Reginster, N Dardenne e mais 3. Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: A cross-sectional study. BMC Musculoskelet Disord, 2015quem mais cita →
- 16R Ramírez-Vélez, A Tordecilla-Sanders, JE Correa-Bautista e mais 3. Validation of multi-frequency bioelectrical impedance analysis versus dual-energy X-ray absorptiometry to measure body fat percentage in overweight/obese Colombian adults. Am J Hum Biol, 2018quem mais cita →
- 17GL Vega, B Adams-Huet e R Peshock. Influence of body fat content and distribution on variation in metabolic risk. J Clin Endocrinol Metab, 2006quem mais cita →
- 18S Patel, N Unwin, R Bhopal e mais 3. A comparison of proxy measures of abdominal obesity in Chinese, European and South Asian adults. Diabet Med, 1999quem mais cita →
- 19JP Després e I Lemieux. Abdominal obesity and metabolic syndrome. Nature, 2006quem mais cita →
- 20E Bertin, C Marcus, JC Ruiz e mais 2. Measurement of visceral adipose tissue by DXA combined with anthropometry in obese humans. Int J Obesity, 2000quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda