  1. Preliminary results of cervical impedance measurements

    Thiago Kira de Souza Saito, Rafael Augusto Pedriali, Cinthia Mara Gabella e mais 2Research on Biomedical Engineering2018

    AbstractIntroduction: In this work, we report the development and initial tests of a measuring system that is used to measure the cervical electrical impedance with the purpose of assessing cervical ripening. The objective is to offer a system that provides real-time information about the cervical electrical impedance…

  2. Boundary element method and simulated annealing algorithm applied to electrical impedance tomography image reconstruction

    Olavo H. Menin, Vanessa Rolnik e Alexandre S. MartinezRevista Brasileira de Ensino de Física2013

    Physics has played a fundamental role in medicine sciences, specially in imaging diagnostic. Currently, image reconstruction techniques are already taught in Physics courses and there is a growing interest in new potential applications. The aim of this paper is to introduce to students the electrical impedance…

  3. A specialized genetic algorithm for the electrical impedance tomography of two-phase flows

    Vanessa P. Rolnik e Paulo Seleghim Jr.Journal of the Brazilian Society of Mechanical Sciences and Engineering2006

    The main objective of this work is to contribute to the development of a new tomographic reconstruction method well suited for processing signals obtained from electrical or other soft sensing field probes. The adopted approach consists in formulating the reconstruction problem in terms of an error function, which…

  4. Electrical impedance tomography and its applicability in respiratory support in neonatal intensive care units: a protocol for a scoping review

    Marília Carvalho Borges, Ana Flávia Lozano Valadão Caserta, Suzana Cristina Almeida e mais 2Critical Care Science2026

    ABSTRACT Introduction: The neonatal intensive care unit employs advanced technologies to manage critical conditions. Electrical impedance tomography is a noninvasive, radiation-free imaging technique that provides real-time monitoring of pulmonary ventilation. The literature on electrical impedance tomography in the…

  5. Can electrical impedance tomography predict successful mechanical ventilation weaning in tracheostomized patients? A single-center observational study

    Walkyria A Macedo Pinto, Flávio G R Freitas, Fernando J S Ramos e mais 2Respiratory Research & Clinical Practice2026

    ABSTRACT Objective: To evaluate whether ventilation variables monitored by electrical impedance tomography (EIT) behaved differently between tracheostomized patients who progressed successfully or failed within 6 h after withdrawal of invasive mechanical ventilation (IMV), as well as to improve the accuracy of failure…

  6. Validation of Electrical Impedance Technique in Real-Time Using the xCELLigence as an Interference-Free Method for Assessing Cytotoxicity of Silver and Hydroxyapatite Nanoparticles

    Ekeveliny A. Veschi, Wanderson de Souza, Myrella K. G. Nobre e mais 7Journal of the Brazilian Chemical Society2024

    This study demonstrated the utility of real-time electrical impedance, utilizing the xCELLigence system to assess the cytotoxic effects of silver nanoparticles (AgNPs) and hydroxyapatite nanoparticles (HANPs) on A549 cells. Method validation confirmed the accuracy and reliability of cell index (CI) measurements. The…

  7. CORRELATION: IMPEDANCE AND TOMOGRAPHY IN IMPLANTS INSERTION IN LUMBAR ARTHRODESIS

    ÉRIKO GONÇALVES FILGUEIRA, LUCIANO DE ALMEIDA FERRER, ITAMAR ALVES BARBOSA NETO e mais 3Coluna/Columna2016

    ABSTRACT Objective: To define whether the electroneurophysiological stimulation would be a safe method for reducing injuries in nerve roots during surgery of lumbar spine arthrodesis, as well as verify whether there is a direct correlation between the intraoperative impedance values and the distance from the medial…

  8. Fat-free mass in overweight and obese older women: analysis of concurrent validity of bioelectrical impedance equations

    Gislane Ferreira de Melo, Daniela Rosa Américo e Maria Fátima GlanerRevista Brasileira de Cineantropometria & Desempenho Humano2015citado por 2 artigos

    Abstract Older adults, especially women, show a higher level of functional dependence and disability because of muscle and bone mass loss and of a progressive increase in body fat mass. These changes in body composition components have been observed by different techniques. The aim of this study was to analyze the…

  9. MULTICHANNEL INTRALUMINAL IMPEDANCE MAY BE USEFUL TO IDENTIFY CLINICALLY RELEVANT ESOPHAGOGASTRIC JUNCTION OUTFLOW OBSTRUCTION

    Felipe Nelson Mendonça e Ricardo Brandt de OliveiraArquivos de Gastroenterologia2026

    ABSTRACT Background: A clinically relevant conclusive diagnosis of esophagogastric junction outflow obstruction (EGJOO) requires a manometric diagnosis, relevant symptoms and adjunct exams supporting outflow obstruction. Multichannel intraluminal impedance measurement provides an evaluation of esophageal clearance…

  10. NUTRITIONAL STATUS IN CHILDREN WITH CANCER: COMPARISON OF DEUTERIUM OXIDE DILUTION WITH BIOELECTRIC IMPEDANCE ANALYSIS AND ANTHROPOMETRY

    Estela Beatriz Behling, José Simon Camelo Júnior, Eduardo Ferriolli e mais 2Revista Paulista de Pediatria2021

    ABSTRACT Objective: To explore changes in the nutritional status of pediatric cancer patients before and after chemotherapy and evaluate the correlation between deuterium oxide dilution, bioelectric impedance analysis, and anthropometry for assessment of body composition. Methods: This study included 14 children (aged…

  11. Interference of heart and transcutaneous oxygen monitoring in the measurement of bioelectrical impedance analysis in preterm newborns

    Viviane C. Comym, Yuri S. Macedu, Eduardo K.P.B. Neves e mais 4Jornal de Pediatria2016citado por 1 artigo

    Abstract Objective: To verify if the connection of electrodes for heart and transcutaneous oxygen monitoring interfere with the measurement of electrical bioimpedance in preterm newborns. Methods: This was a prospective, blinded, controlled, cross-sectional, crossover study that assessed and compared paired measures…

  12. STAPHYLOCOCCUS AUREUS BIOFILM FORMATION ON POLYPYRROLE: AN ELECTRICAL OVERVIEW

    Erlon R. Cordeiro, Antonio W. C. Fernandes, Alessandra F. C. Pereira e mais 3Química Nova2015

    The development of organic devices based on conducting polymers for biofilm detection requires the combination of superior electrical response and high surface area for biofilm incorporation. Polypyrrole is a potential candidate for application in biofilm detection and control due to its characteristic superior…

  13. PROLONGED GASTROESOPHAGEAL REFLUX MONITORING BY IMPEDANCE-PHMETRY: A REVIEW OF THE SUBJECT PONDERED WITH OUR EXPERIENCE WITH 1,200 CASES

    Ary NASI, Natália Sousa Freitas QUEIROZ e Nelson H MICHELSOHNArquivos de Gastroenterologia2018citado por 1 artigo

    ABSTRACT BACKGROUND: Prolonged monitoring increased our knowledge on gastroesophageal reflux (GER), and the disease became known as gastroesophageal reflux disease (GERD). Prolonged reflux monitoring permits the diagnosis of GERD when endoscopic findings are not enough to characterize it. OBJECTIVE: The objective of…

  14. Application of bioelectrical impedance in newborns: an integrative review

    Catiuscie Cabreira-da Silva-Tortorella, Adriana Masiero-Kühl, Andréa Vieir-Pereira-Coradine e mais 2Nutrición Hospitalaria2023citado por 1 artigo

    Abstract Objective: the objective of this study was to identify the use of bioelectrical impedance in newborns (NB), as this is an easy-to-apply and non-invasive method of measurement that can be used for distinguishing fat-free mass (FFM), fat mass (FM), and total body water (TBW). Method: this was an integrative…

  15. Bio-electrical properties of apples in function of sample volume and temperature and probe configuration

    Honghao Cai, Jiaqing Wu, Jiashun Chen e mais 1Revista Brasileira de Engenharia Agrícola e Ambiental2025

    ABSTRACT The quality of fruit can be quickly and accurately assessed using bio-impedance spectroscopy, but no comprehensive studies have been conducted on how the detection conditions affect their bio-electrical properties. Accordingly, this study aims to investigate the effects of sample volume, sample temperature…

  16. COMBINED 24-HOURS ESOPHAGEAL PH MONITORING AND MULTICHANNEL INTRALUMINAL IMPEDANCE FOR COMPARISON OF GASTROESOPHAGEAL REFLUX IN CHILDREN WITH TYPICAL VERSUS ATYPICAL SYMPTOMS OF GASTROESOPHAGEAL REFLUX DISEASE

    Seyed Mohsen DEHGHANI, Seyed Alireza TAGHAVI, Hazhir JAVAHERIZADEH e mais 1Arquivos de Gastroenterologia2016

    ABSTRACT Background - Gastroesophageal reflux disease is the most common esophageal disorder in pediatrics. Objective - The aim of this study was to compare reflux parameters of typical and atypical symptoms of gastroesophageal reflux disease using 24-hour esophageal pH monitoring and multichannel intraluminal…

  17. Analysis of electrical and piezoresistive properties of mortar reinforced with carbon microfibers

    João Batista Lamari Palma e Silva, Camila Tiemi Ozaki e Silva, Stephanie Cucolo Marçula e mais 2Ambiente Construído2026

    Abstract Multifunctional mortars have been developed for applications in self-sensing systems, electromagnetic shielding, cathodic protection, and other areas. To achieve this, it is necessary to incorporate conductive materials, which often reduce mechanical properties, making their use challenging. Carbon microfiber…

  18. Validation of a bioelectrical impedance analysis system for body composition assessment in patients with COPD

    Fernanda Rodrigues Fonseca, Manuela Karloh, Cintia Laura Pereira de Araujo e mais 2Jornal Brasileiro de Pneumologia2018

    ABSTRACT Objective: To investigate the validity of an eight-contact electrode bioelectrical impedance analysis (BIA) system within a household scale for assessing whole body composition in COPD patients. Methods: Seventeen patients with COPD (mean age = 67 ± 8 years; mean FEV1 = 38.6 ± 16.1% of predicted; and mean…

  19. Comparison of bioelectrical impedance with skinfold thickness and X-ray absorptiometry to measure body composition in HIV-infected with lipodistrophy

    H. Siqueira Vassimon, A. A. Jordao, F. J. Albuquerque de Paula e mais 2Nutrición Hospitalaria2011citado por 1 artigo

    Introduction: Human immunodeficiency vírus (HIV)-associated lipodystrophy syndrome (LS) includes body composition and metabolic alterations. Lack of validated criteria and tools make difficult to evaluate body composition in this group. Objective: The aim of the study was to compare different methods to evaluate body…