Journal of Applied Oral Science2013
Temperature and curing time affect composite sorption and solubility
Fabricio Luscino Alves de Castro, Bruno Barbosa Campos, Kely Firmino Bruno e Rogerio Vieira Reges
em inglês
citado por 3 artigoscita 30 obras, 2 no acervo
resumo
Objective: This study evaluated the effect of temperature and curing time on composite sorption and solubility. Material and Methods: Seventy five specimens (8×2 mm) were prepared using a commercial composite resin (ICE, SDI). Three temperatures (10°C, 25°C and 60°C) and five curing times (5 s, 10 s, 20 s, 40 s and 60 s) were evaluated. The specimens were weighed on an analytical balance three times: A: before storage (M1); B: 7 days after storage (M2); C: 7 days after storage plus 1 day of drying (M3). The storage solution consisted of 75% alcohol/25% water. Sorption and solubility were calculated using these three weights and specimen dimensions. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U Tests (α=5%). Results: The results showed that time, temperature and their interaction influenced the sorption and solubility of the composite (p<0.05). At 60°C, the composite sorption showed an inverse relationship with the curing time (p<0.05). The composite cured for 5 s showed higher sorption for the 40 s or 60 s curing times when compared with all temperatures (p<0.05). Curing times of 20 s and 40 s showed similar sorption data for all temperatures (p>0.05). The 60°C composite temperature led to lower values of sorption for all curing times when compared with the 10°C temperature (p<0.05). The same results were found when comparing 10°C and 25°C (p<0.05), except that the 20 s and 40 s curing times behaved similarly (p>0.05). Solubility was similar at 40 s and 60 s for all temperatures (p>0.05), but was higher at 10°C than at 60°C for all curing times (p<0.05). When the composite was cured at 25°C, similar solubility values were found when comparing the 5 s and 10 s or 20 s and 40 s curing times (p>0.05). Conclusions: In conclusion, higher temperatures or longer curing times led to lower sorption and solubility values for the composite tested; however, this trend was only significant in specific combinations of temperature and curing times.
como citar · ABNT NBR 6023
CASTRO, Fabricio Luscino Alves de et al. Temperature and curing time affect composite sorption and solubility. Journal of Applied Oral Science, 2013. DOI: 10.1590/1678-7757201302298.
Referências
30 obras citadas · 2 no acervo
- 1JR Bausch, C Lange e CL Davidson. The influence of temperature on some physical properties of dental composites. J Oral Rehabil, 1981quem mais cita →
- 2WF Caughman, FA Rueggeberg e JW Jr Curstis. Clinical guidelines for photocuring restorative resins. J Am Dent Assoc, 1995quem mais cita →
- 3WD Cook, GP Simon, PJ Burchill e mais 2. Curing kinetics and thermal properties of vinyl ester resins. J Appl Polym Sci, 1997quem mais cita →
- 4JB Costa, TJ Hilton e EJ Jr Swift. Preheating composites. J Esthet Rest Dent, 2011quem mais cita →
- 5M; Rueggeberg FA Daronch e Goes MF De. Monomer conversion of pre-heated composite. J Dent Res, 2005quem mais cita →
- 6M Daronch, FA Rueggeberg, Goes MF De e mais 1. Polymerization kinectics of pre-heated composite. J Dent Res, 2006quem mais cita →
- 7M Daronch, FA Rueggeberg, L Moss e mais 1. Clinically relevant issues related to preheating composites. J Esthet Restor Dent, 2006quem mais cita →
- 8S Deb, Silvio L Di, HE Mackler e mais 1. Pre-warming of dental composites. Dent Mater, 2011quem mais cita →
- 9DI El-Korashy. Post-gel shrinkage strain and degree of conversion of pre-heated composite resin cured using different regimens. Oper Dent, 2010quem mais cita →
- 10PL Fan, A Edahl, RL Leung e mais 1. Alternative interpretations of water sorption values of composite resins. J Dent Res, 1985quem mais cita →
- 11JL Ferracane. Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins. Dent Mater, 1985quem mais cita →
- 12JL Ferracane. Hygroscopic and hydrolytic effects in dental polymer networks. Dent Mater, 2006quem mais cita →
- 13NR Froes-Salgado, LM Silva, Y Kawano e mais 3. Composite pre-heating: effects on marginal adaptation, degree of conversion and mechanical properties. Dent Mater, 2010quem mais cita →
- 14J Ge, M Trujillo e J Stansbury. Synthesis and photopolymerization of low shrinkage methacrylate monomers containing bulky substituent groups. Dent Mater, 2005quem mais cita →
- 15S Ito, M Hashimoto, B Wadgaonkar e mais 3. Effect of resin hydrophilicity on water sorption and changes in modulus of elasticity. Biomaterials, 2001quem mais cita →
- 16U Lohbauer, S Zinelis, C Rahiotis e mais 2. The effect of composite resin pre-heating on monomer conversion and polymerization shrinkage. Dent Mater, 2009quem mais cita →
- 17LG Lovell, H Lu, JE Elliot e mais 2. The effect of cure rate on the mechanical properties of dental resins. Dent Mater, 2001quem mais cita →
- 18LG Lovell, SM Newman e CN Bowman. The effects of light intensity, temperature, and comonomer composition on the polymerization behavior of dimethacrylate dental resins. J Dent Res, 1999quem mais cita →
- 19S Lucey, CD Lynch, NJ Ray e mais 2. Effect of pre-heating on the viscosity and microhardness of a composite resin. J Oral Rehab, 2010quem mais cita →
- 20FM Mundim, LF Garcia, DR Cruvinel e mais 3. Color stability, opacity and degree of conversion of pre-heated composites. J Dent. 2011;39(Suppl. 1)quem mais cita →
Quem cita esta obra
3 artigos do acervo
- 2015: citada em 1 artigo
- 2017: citada em 1 artigo
- 2019: citada em 1 artigo
quem fala desta obra
24 pessoas- Monica Soares de ALBUQUERQUE1 artigo · 2019
- Rodivan BRAZ1 artigo · 2019
- Pedro Tardelly Diniz FILGUEIRA1 artigo · 2019
- Marcus Vinicius Lia FOOK1 artigo · 2019
- Eliane Alves de LIMA1 artigo · 2019
- Armiliana Soares NASCIMENTO1 artigo · 2019
- Leonardo Jose Rodrigues de OLIVEIRA1 artigo · 2019
- José Filipe Bacalhau RODRIGUES1 artigo · 2019
- João Batista Morais dos SANTOS1 artigo · 2019
- Kleilton Oliveira SANTOS1 artigo · 2019
os artigos
- Physicomechanical and thermal analysis of bulk-fill and conventional compositesArmiliana Soares NASCIMENTO e mais 10 · Brazilian Oral Research · 2019
- Does laser diode irradiation improve the degree of conversion of simplified dentin bonding systems?Leticia Ferreira de Freitas BRIANEZZI e mais 5 · Journal of Applied Oral Science · 2017
- Pre-heating mitigates composite degradationJessika Calixto da SILVA e mais 6 · Journal of Applied Oral Science · 2015
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda