Journal of Applied Oral Science2011
A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants
Felipe Miguel Saliba, Mayra Cardoso, Marcelo Ferreira Torres, Alexandre Carvalho Teixeira, Eduardo José Veras Lourenço e Daniel de Moraes Telles
em inglês
resumo
OBJECTIVES: Previous studies that evaluated the torque needed for removing dental implant screws have not considered the manner of transfer of the occlusal loads in clinical settings. Instead, the torque used for removal was applied directly to the screw, and most of them omitted the possibility that the hexagon could limit the action of the occlusal load in the loosening of the screws. The present study proposes a method for evaluating the screw removal torque in an anti-rotational device independent way, creating an unscrewing load transfer to the entire assembly, not only to the screw. MATERIAL AND METHODS: Twenty hexagonal abutments without the hexagon in their bases were fixed with a screw to 20 dental implants. They were divided into two groups: Group 1 used titanium screws and Group 2 used titanium screws covered with a solid lubricant. A torque of 32 Ncm was applied to the screw and then a custom-made wrench was used for rotating the abutment counterclockwise, to loosen the screw. A digital torque meter recorded the torque required to loosen the abutment. RESULTS: There was a significant difference between the means of Group 1 (38.62±6.43 Ncm) and Group 2 (48.47±5.04 Ncm), with p=0.001. CONCLUSION: This methodology was effective in comparing unscrewing torque values of the implant-abutment junction even with a limited sample size. It confirmed a previously shown significant difference between two types of screws.
como citar · ABNT NBR 6023
SALIBA, Felipe Miguel et al. A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants. Journal of Applied Oral Science, 2011. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572011000100013. Acesso em: 27 nov. 2026.
Referências
20 obras citadas · 1 no acervo
- 1PP Binon. The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont, 1996quem mais cita →
- 2RL Burguete, RB Johns, T King e mais 1. Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosthet Dent, 1994quem mais cita →
- 3B Carlson e GE Carlsson. Prosthodontic complications in osseointegrated dental implant treatment. Int J Oral Maxillofac Implants, 1994quem mais cita →
- 4RM Cibirka, SK Nelson, BR Lang e mais 1. Examination of the implant-abutment interface after fatigue testing. J Prosthet Dent, 2001quem mais cita →
- 5A Ekfeldt, GE Carlsson e G Börjesson. Clinical evaluation of single-tooth restorations supported by osseointegrated implants: a retrospective study. Int J Oral Maxillofac Implants, 1994quem mais cita →
- 6RE Jung, BE Pjetursson, R Glauser e mais 3. A systematic review of the 5-year survival and complication rates of implant-supported single crowns. Clin Oral Implants Res, 2008quem mais cita →
- 7A Khraisat, A Hashimoto, S Nomura e mais 1. Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system. J Prosthet Dent, 2004quem mais cita →
- 8SK Kim, JB Lee, JY Koak e mais 3. An abutment screw loosening study of a Diamond Like Carbon-coated CP titanium implant. J Oral Rehabil, 2005quem mais cita →
- 9ME Kreissl, T Gerds, R Muche e mais 2. Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years. Clin Oral Implants Res, 2007quem mais cita →
- 10LA Lang, B Kang, RF Wang e mais 1. Finite element analysis to determine implant preload. J Prosthet Dent, 2003quem mais cita →
- 11LA Lang, RF Wang e KB May. The influence of abutment screw tightening on screw joint configuration. J Prosthet Dent, 2002quem mais cita →
- 12WC Martin, RD Woody, BH Miller e mais 1. Implant abutment screw rotations and preloads for four different screw materials and surfaces. J Prosthet Dent, 2001quem mais cita →
- 13BE Pjetursson, K Tan, NP Lang e mais 3. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. Clin Oral Implants Res, 2004quem mais cita →
- 14I Sailer, A Philipp, A Zembic e mais 3. A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions. Clin Oral Implants Res, 2009quem mais cita →
- 15RA Stüker, ER Teixeira, JCP Beck e mais 1. Preload and torque removal evaluation of three different abutment screws for single standing implant restorations. J Appl Oral Sci, 2008no acervo →
- 16TD Taylor. Prosthodontic problems and limitations associated with osseointegration. J Prosthet Dent, 1998quem mais cita →
- 17A Theoharidou, HP Petridis, K Tzannas e mais 1. Abutment screw loosening in single-implant restorations: a systematic review. Int J Oral Maxillofac Implants, 2008quem mais cita →
- 18GK Tzenakis, WW Nagy, RA Fournelle e mais 1. The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws. J Prosthet Dent, 2002quem mais cita →
- 19RF Wang, B Kang, LA Lang e mais 1. The dynamic natures of implant loading. J Prosthet Dent, 2009quem mais cita →
- 20EI Weiss, D Kozak e MD Gross. Effect of repeated closures on opening torque values in seven abutment-implant systems. J Prosthet Dent, 2000quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda