Jornal Brasileiro de Patologia e Medicina Laboratorial2014
Reticulocyte count: comparison among methods
Karina Augusta Viana, Olindo Assis Martins Filho, Luci Maria Sant’Ana Dusse, Renato Sathler Avelar, Danielle Marquete Vitelli Avelar, Beatriz Carvalho, Claudia Maria Franco Ribeiro, Lis Ribeiro do Valle Antonelli, Andrea Teixeira e Maria das Graças Carvalho
em inglês
citado por 1 artigocita 23 obras, 2 no acervo
resumo
Introduction: The automated counting of reticulocytes has some advantages over the manual method routinely used in clinical laboratories. Technological innovations provide more statistically reliable results, while optimizing the time to perform this test. However, the cost for implementing the automated procedure in laboratory routines still constitutes a barrier to its use in small- and medium-size Brazilian laboratories. Objective: This study evaluated the performance of a new laboratory protocol for reticulocyte counting by flow cytometry using acridine orange (FC/AO), compared with the manual method and with another automated one by flow cytometry using the commercial kit BD Retic-Count (FC/RC) Conclusion: The results showed that, besides being comparable to the manual method, still considered standard, the evaluated new protocol is economically more advantageous than the automated methods currently available, and its cost is comparable to that of the manual method for laboratories that already have appropriate equipment and infrastructure.
como citar · ABNT NBR 6023
VIANA, Karina Augusta et al. Reticulocyte count: comparison among methods. Jornal Brasileiro de Patologia e Medicina Laboratorial, 2014. DOI: 10.5935/1676-2444.20140037.
Referências
23 obras citadas · 2 no acervo
- 1A. F ALI. Is manual reticulocyte count a reliable option for under resourced countries?. J Pak Med Assoc, 2010quem mais cita →
- 2B. J BAIN. Células sanguíneas: um guia prático. 2004quem mais cita →
- 3C BRIGGS. Comparison of the automated reticulocyte counts and immature reticulocyte fraction measurements obtained with the ABX Pentra 120 Retic Blood Analyzer and the Sysmex XE-120 Automated Hematology Analyzer. Lab Hematol, 2001quem mais cita →
- 4M BUTTARELLO. Flow cytometric reticulocyte counting. Parallel evaluation of five fully automated analyzers: an NCCLS-ICSH approach. Am J Clin Pathol, 2001quem mais cita →
- 5J. M CARTER. Counting reticulocytes by flow cytometry: use of thiazole orange. Clin Lab Haemat, 1989quem mais cita →
- 6G D'ONOFRIO e G ZINI. Clinical applications of new reticulocytes parameters. Haematologica, 2002quem mais cita →
- 7J DACIE e S LEWIS. Practical haematology. 1984quem mais cita →
- 8B. H DAVIS e N. C BIGELOW. Clinical flow cytometric reticulocyte analysis. Pathobiology, 1990quem mais cita →
- 9R FAILACE. Hemograma: manual de interpretação. 2009quem mais cita →
- 10S. M LEWIS. Hematologia prática de Dacie e Lewis. 2006quem mais cita →
- 11NCCLS e NCCLS. Methods for reticulocyte counting (automated blood cell counters, flow cytometry, and supravital dyes): approved guideline – second edition. NCCLS document H44-A2, 2004quem mais cita →
- 12L PENG. Automated reticulocyte counting using the Sysmex RAM-1. Clin Lab Haem, 2001quem mais cita →
- 13E PIVA. Automated reticulocyte counting: state of the art and clinical applications in the evaluation of erythropoiesis. Clin Chem Lab Med, 2010quem mais cita →
- 14R. S RILEY. Reticulocyte enumeration: past & present. Lab Med, 2001quem mais cita →
- 15B. F RODAK. Hematology: clinical principles and applications. 2002quem mais cita →
- 16R. M ROWAN. Reference method, quality control and automation of reticulocyte count. Pure & Appl Chem, 1991quem mais cita →
- 17B RUDENSKY. Comparison of a semi-automated new Coulter methylene blue method with fluorescence flow cytometry in reticulocyte counting. Scand J Clin Lab Invest, 1997quem mais cita →
- 18P. A SELIGMAN. Automated analysis of reticulocytes using fluorescent staining with both acridine orange and immunofluorescence technique. Am J Hematol, 1983quem mais cita →
- 19M SIMIONATTO. Estudo comparativo de métodos de contagem de reticulócitos para controle de qualidade. 2009quem mais cita →
- 20M SIMIONATTO. Analysis of manual reticulocyte counts in the clinical laboratories of Ponta-Grossa and Campos Gerais, PR, Brazil. Rev Bras Hematol Hemoter, 2009no acervo →
Quem cita esta obra
1 artigo do acervo
quem fala desta obra
7 pessoas- Lis R. V. Antonelli1 artigo · 2016
- Danielle M. V. Avelar1 artigo · 2016
- Renato S. Avelar1 artigo · 2016
- Maria das Graças Carvalhoautocitação1 artigo · 2016
- Luci Maria S. Dusse1 artigo · 2016
- Olindo A. Martins Filho1 artigo · 2016
- Karina Augusta Vianaautocitação1 artigo · 2016
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda