Jornal Brasileiro de Patologia e Medicina Laboratorial2014

Flow cytometry reticulocyte counting using acridine orange: validation of a new protocol

Karina Augusta Viana, Maria das Graças Carvalho, Luci Maria Sant'Ana Dusse, Aline Caldeira Fernandes, Renato Sathler Avelar, Danielle Marquete Vitelli Avelar, Beatriz Carvalho, Claudia Maria Franco Ribeiro, Lis Ribeiro do Valle Antonelli, Andrea Teixeira e Olindo Assis Martins Filho

em inglês

citado por 1 artigocita 14 obras

resumo

Introduction: Currently, the reticulocyte counting is a challenge for clinical laboratories in Brazil, mainly for the ordinary ones, which still use the manual method. This method has some limitations, since it consists of a laborious method, time consuming, with low accuracy. Objectives: This study has developed and evaluated the performance of a New Laboratory Protocol for flow cytometry (FC) reticulocytes counting using acridine orange (AO) as dye, aiming to standardize a more precise, easy, fast implementation, and low cost protocol. After standardization of the New Protocol (FC/AO), it was compared with the manual method. The results were analyzed according to the recommendations of the National Committee for Clinical Laboratory Standards (NCCLS), now known as Clinical and Laboratory Standards Institute (CLSI), to evaluate the interchangeability of methods in linear regression analysis and paired t test, besides other quality control tests. Conclusion: Based on these results concerning to the correlation between the methods and the tests related to quality control, we can admit that FC/AO for reticulocyte counting shows undeniable advantages when compared to the preexisting manual method.

como citar · ABNT NBR 6023

VIANA, Karina Augusta et al. Flow cytometry reticulocyte counting using acridine orange: validation of a new protocol. Jornal Brasileiro de Patologia e Medicina Laboratorial, 2014. DOI: 10.5935/1676-2444.20140014.

Referências

14 obras citadas

  1. 1M. BUTTARELLO, P. BULIAN, M. DE PRÀ e mais 2. Reticulocyte quantification by Coulter MAXM VCS (volume, conductivity, light scatter) technology. Clinical Chemistry, 1996quem mais cita →
  2. 2M. BUTTARELLO. Flow cytometric reticulocyte counting. Parallel evaluation of five fully automated analyzers: an NCCLS-ICSH approach. American Journal of Clinical Pathology, 2001quem mais cita →
  3. 3J. M. CARTER, P. A. McSWEENEY, P. J. WAKEM e mais 1. Counting reticulocytes by flow cytometry: use of thiazole orange. Clin Lab Haemat, 1989quem mais cita →
  4. 4R. FAILACE. Hemograma: manual de interpretacao. 2009quem mais cita →
  5. 5L. V. HOVE, W. GOOSSENS, V. V. DUPPEN e mais 1. Reticulocyte count thiazole orange. A flow cytometry method. Clin Lab Haemat, 1990quem mais cita →
  6. 6NCCLS e NCCLS. Methods for reticulocyte counting (automated blood cell counters, flow cytometry, and supravital dyes); approved guideline - second edition. 2004quem mais cita →
  7. 7L. PENG, H. YANG, H. JIANG e mais 2. Automated reticulocyte counting using the Sysmex RAM-1. Clin Lab Haem, 2001quem mais cita →
  8. 8E. PIVA, C. BRUGNARA, L. CHIANDETTI e mais 1. Automated reticulocyte counting: state of the art and clinical applications in the evaluation of erythropoiesis. Clin Chem Lab Med, 2010quem mais cita →
  9. 9R. S. RILEY, J. M. BEN-EZRA, A. TIDWELL e mais 1. Reticulocyte analysis by flow cytometry and other techniques. Hematology/Oncology Clinics of North America, 2002quem mais cita →
  10. 10R. M. ROWAN. Reference method, qualit control and automation of reticulocyte count. Pure and Applied Chemistry, 1991quem mais cita →
  11. 11B. RUDENSKY. Comparasion of a semi-automated new coulter methylene blue method with fluorescence flow cytometry in reticulocyte counting. Scand J Clin Lab, 1997quem mais cita →
  12. 12R. A. SAVAGE, D. P. SKOOG e A. RABINOVITCH. Analytic inaccuracy and imprecision in reticulocyte counting: a preliminary report from College of American Pathologists Reticulocyte Project. Blood Cells, 1985quem mais cita →
  13. 13A. WEARNE, H. ROBIN, D. E. JOSHUA e mais 1. Automated enumaration of reticulocytes using acridine orange. Pathology, 1985quem mais cita →
  14. 14M. A. ZAGO, R. P. FALCÃO e R. PASQUINI. Hematologia: fundamentos e pratica. 2001quem mais cita →

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

10 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações