Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial2025

Intraoral stereoradiography visualization with virtual reality: peri-implant bone level estimation accuracy - An in vitro study

Jorge Ferreira da Costa, João Caramês e Daniel Hachmeister

em inglês

cita 19 obras

resumo

Abstract Objectives: The main objectives of this in vitro study were to evaluate the accuracy and precision of stereoradiography with virtual reality in measuring peri-implant bone level compared to conventional 2D radiography, and to find which stereoscopic angles between images lead to higher accuracy and precision. Another objective was to develop a virtual reality method for viewing pairs of stereoscopic radiographs, to archive, to present, and analyze the acquired stereoscopic images. Methods: A blinded laboratory study compared 40 samples of randomly positioned implants in 10 artificial bone blocks simulating random bone defects and crestal angulations. 320 pairs of different stereoscopic angulation images were analyzed using a head-mounted display system. A total of 1280 measurements of the mesial, distal, buccal, and lingual margins were made, in a randomized order, using 0.4 mm cylindrical threads as reference, giving a 0.2 mm maximum precision in measurements. Results: The median absolute error and relative error interquartile range were lower in stereoscopic images. The observers’ error of bone height estimation reduced substantially when stereoscopic images were used, even at low angular disparities such as 2° of stereopsis. Observers reported viewing discomfort at angles above 6º. Conclusions: Stereoradiography significantly reduced the error in bone height estimation, with any stereoscopic angle, compared to 2D. Augmented/virtual reality technology empowers stereoradiography, offering a more affordable and user-friendly imaging system.

como citar · ABNT NBR 6023

COSTA, Jorge Ferreira da; CARAMÊS, João; HACHMEISTER, Daniel. Intraoral stereoradiography visualization with virtual reality: peri-implant bone level estimation accuracy - An in vitro study. Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial, 2025. DOI: 10.24873/J.RPEMD.2025.06.1427.

Referências

19 obras citadas

  1. 1I Gupta, A Chaudhry, S Savita e mais 1. Radiographic Assessment of Peri-implant Bone Level - A Comparative Study of Digital Intraoral and Digital Panoramic Radiography. Stomatol Glas Srb, 2019quem mais cita →
  2. 2MJ Kim, SS Lee, M Choi e mais 3. Developing evidence-based clinical imaging guidelines of justification for radiographic examination after dental implant installation. Bmc Med IMAGING, 2020quem mais cita →
  3. 3M Dave, J Davies, R Wilson e mais 1. A comparison of cone beam computed tomography and conventional periapical radiography at detecting peri-implant bone defects. Clin Oral Implants Res, 2013quem mais cita →
  4. 4S Barootchi, L Tavelli, J Majzoub e mais 3. Ultrasonographic Tissue Perfusion in Periimplant Health and Disease. J Dent Res, 2022quem mais cita →
  5. 5K Orhan, G Serindere, CA Belgin e mais 1. Evaluation of the visibility of peri-implant bone defects using ultrasonography with two types of probes. J Ultrason, 2021quem mais cita →
  6. 6R Siqueira, K Sinjab, Y-C Pan e mais 3. Comprehensive Peri-implant Tissue Evaluation with Ultrasonography and Cone-Beam Computed Tomography: A Pilot Study HHS Public Access. Clin Oral Implant Res, 2021quem mais cita →
  7. 7N Miotk, FS Schwindling, M Zidan e mais 3. Reliability and accuracy of intraoral radiography, cone beam CT, and dental MRI for evaluation of peri-implant bone lesions at zirconia implants − an ex vivo feasibility study. J Dent, 2023quem mais cita →
  8. 8S Kühl, S Zürcher, NU Zitzmann e mais 3. Detection of peri-implant bone defects with different radiographic techniques - a human cadaver study. Clin Oral Implants Res, 2016quem mais cita →
  9. 9L Hollender e B Rockler. Radiographic evaluation of osseointegrated implants of the jaws. Experimental study of the influence of radiographic techniques on the measurement of the relation between the implant and bone. Dentomaxillofac Radiol, 1980quem mais cita →
  10. 10RKW Schulze e B d’Hoedt. Mathematical analysis of projection errors in “paralleling technique” with respect to implant geometry. Clin Oral Implants Res, 2001quem mais cita →
  11. 11IP Sewerin. Errors in radiographic assessment of marginal bone height around osseointegrated implants. Eur J Oral Sci, 1990quem mais cita →
  12. 12HR Raper. Elementary And Dental Radiography. 1913quem mais cita →
  13. 13RA Sherlock e WM Aitken. A method of precision position determination using x-ray stereography. Phys Med Biol, 1980quem mais cita →
  14. 14MHPH van Beurden, WA IJsselsteijn e JF Juola. Effectiveness of stereoscopic displays in medicine: A review. 3D Res, 2012quem mais cita →
  15. 15GDR Freitas, ML Poleti, CRG Xavier e mais 2. Fabrication of plaster models with radiographic features of human bone: a pilot study by fractal analysis. Rgo, 2012quem mais cita →
  16. 16B Efron e Tibshirani Rj. An Introduction To The Bootstrap. 1994quem mais cita →
  17. 17NP Lang, TG Wilson e EF Corbet. Biological complications with dental implants: their prevention, diagnosis and treatment. Clin Oral Implants Res, 2000quem mais cita →
  18. 18E De Smet, R Jacobs, F Gijbels e mais 1. The accuracy and reliability of radiographic methods for the assessment of marginal bone level around oral implants. Dentomaxillofacial Radiol, 2002quem mais cita →
  19. 19L Leroy. Eyestrain Reduction In Stereoscopy. Wiley, 2016quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações