Revista Brasileira de Engenharia Biomédica2013
A comparative study for different shielding material composition and beam geometry applied to PET facilities: simulated transmission curves
Gabriela Hoff e Paulo Roberto Costa
em inglês
resumo
The aim of this work is to simulate transmission data for different beam geometry and material composition in order to evaluate the effect of these parameters on transmission curves. The simulations are focused on outgoing spectra for shielding barriers used in PET facilities. The behavior of the transmission was evaluated as a function of the shielding material composition and thickness using Geant4 Monte Carlo code, version 9.2 p 03.The application was benchmarked for barited mortar and compared to The American Association of Physicists in Medicine (AAPM) data for lead. Their influence on the transmission curves as well the study of the influence of the shielding material composition and beam geometry on the outgoing spectra were performed. Characteristics of transmitted spectra, such as shape, average energy and Half-Value Layer (HVL), were also evaluated. The Geant4 toolkit benchmark for the energy resulting from the positron annihilation phenomena and its application in transmission curves description shown good agreement between data published by American Association on Physicists in Medicine task group 108 and experimental data published by Brasil. The transmission properties for different material compositions were also studied and have shown low dependency with the considered thicknesses. The broad and narrow beams configuration presented significant differences on the result. The fitting parameter for determining the transmission curves equations, according to Archer model is presented for different material. As conclusion were defined that beam geometry has significant influence and the composition has low influence on transmission curves for shielding design for the range of energy applied to PET.
como citar · ABNT NBR 6023
HOFF, Gabriela; COSTA, Paulo Roberto. A comparative study for different shielding material composition and beam geometry applied to PET facilities: simulated transmission curves. Revista Brasileira de Engenharia Biomédica, 2013. DOI: 10.4322/RBEB.2013.006.
Referências
18 obras citadas
- 1S Agostinelli, J Allison, K Amako e mais 74. Geant4 - a simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A, 2003quem mais cita →
- 2J Allison, K Amako, J Apostolakis e mais 49. Pia MG, Ribon A, Rodrigues P, Russo G, Sadilov S, Santin G, Sasaki T, Smith D, Starkov N, Tanaka S, Tcherniaev E, Tomé B, Trindade A, Truscott P, Urban L, Verderi M, Walkden A, Wellisch P, Williams DC, Wright D, Yoshida H: Geant4 developments and applications. IEEE Transactions on Nuclear Science, 2006quem mais cita →
- 3AT Almeida Junior. Caracterização da barita e do vidro cristal como atenuadores na blindagem das radiações X e Gama. 2005quem mais cita →
- 4BR Archer, JI Hornby e SC Bushong. Diagnostic X-ray shielding design based on an empirical model of photon attenuation. Health Physics, 1983quem mais cita →
- 5RB Brasil. Study and projects application to system shield from PET/CT Facilities. 2009quem mais cita →
- 6B Brinkley, M Yester e S White. Calculation of broad beam transmission factor for 511 keV: Photons using energy spectra measured in the presence of scatter. In: 2009 AAPM Annual Meeting Program. Medical Physics, 2009quem mais cita →
- 7J Cruzate e A Discacciatti. Shielding of medical facilities. Shielding design considerations for PET-CT facilities. 2008quem mais cita →
- 8D Demir e G Keles. Radiation transmission of concrete including boron waste for 59: 54 and 80.99 keV gamma rays. Nuclear Instruments and Methods in Physics Research Section B, 2006quem mais cita →
- 9M Elschot, TC Wit e HWAM Jong. The influence of self-absorption on PET and PET/CT shielding requirements. Medical Physics, 2010quem mais cita →
- 10G Hoff, SF Firmino e WP Souza. De. Influence of shielding composition on transmission curves determination for diagnostic radiology: A Monte Carlo study using the GEANT4 code. IEEE Nuclear Science Symposium Conference Record: Proceedings of the Nuclear Science Symposium Conference Record; 2009; Orlando, 2009quem mais cita →
- 11JH Hubbell e SM Seltzer. Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients from 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 additional substances of dosimetric interest. 1996quem mais cita →
- 12G Hoff. Simulating curves of transmission used on PET/CT applications, using Geant4 toolkit. IEEE Nuclear Science Symposium Conference Record: Proceedings of the Nuclear Science Symposium Conference Record; 2010; Knoxvile, 2010quem mais cita →
- 13International Commission on Radiation Units and Measurements. Report 44 - Tissue substitutes in radiation dosimetry and measurements. 1989quem mais cita →
- 14MT Madsen, JA Anderson, JR Halama e mais 6. AAPM Task Group 108: PET and PET/CT shielding requirements. Medical Physics, 2006quem mais cita →
- 15National Council on Radiation Protection and Measurements. Report 147 - Structural shielding design for medical X-ray imaging facilities. 2005quem mais cita →
- 16DJ Simpkin. Shielding requirements for constant-potential diagnostic X-ray beams determined by a Monte Carlo calculation. Health Physics, 1989quem mais cita →
- 17DJ Simpkin. Transmission data for shielding diagnostic X-ray facilities. Health Physics, 1995quem mais cita →
- 18K Singh, H Singh, V Sharma e mais 5. Gamma-ray attenuation coefficients in bismuth borate glasses. Nuclear Instruments and Methods in Physics Research Section B, 2002quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda