Brazilian Journal of Physical Therapy2013
Wrist electrogoniometry: are current mathematical correction procedures effective in reducing crosstalk in functional assessment?
Fabiana A. Foltran, Luciana C. C. B. Silva, Tatiana O. Sato e Helenice J. C. G. Coury
em inglês
resumo
BACKGROUND: The recording of human movement is an essential requirement for biomechanical, clinical, and occupational analysis, allowing assessment of postural variation, occupational risks, and preventive programs in physical therapy and rehabilitation. The flexible electrogoniometer (EGM), considered a reliable and accurate device, is used for dynamic recordings of different joints. Despite these advantages, the EGM is susceptible to measurement errors, known as crosstalk. There are two known types of crosstalk: crosstalk due to sensor rotation and inherent crosstalk. Correction procedures have been proposed to correct these errors; however no study has used both procedures in clinical measures for wrist movements with the aim to optimize the correction. OBJECTIVE: To evaluate the effects of mathematical correction procedures on: 1) crosstalk due to forearm rotation, 2) inherent sensor crosstalk; and 3) the combination of these two procedures. METHOD: 43 healthy subjects had their maximum range of motion of wrist flexion/extension and ulnar/radials deviation recorded by EGM. The results were analyzed descriptively, and procedures were compared by differences. RESULTS: There was no significant difference in measurements before and after the application of correction procedures (P<0.05). Furthermore, the differences between the correction procedures were less than 5° in most cases, having little impact on the measurements. CONCLUSIONS: Considering the time-consuming data analysis, the specific technical knowledge involved, and the inefficient results, the correction procedures are not recommended for wrist recordings by EGM.
como citar · ABNT NBR 6023
FOLTRAN, Fabiana A. et al. Wrist electrogoniometry: are current mathematical correction procedures effective in reducing crosstalk in functional assessment? Brazilian Journal of Physical Therapy, 2013. DOI: 10.1590/S1413-35552012005000067.
Referências
35 obras citadas · 2 no acervo
- 1G-A Hansson, I Balogh, K Ohlsson e mais 2. Goniometer measurement and computer analysis of wrist angles and movements applied to occupational repetitive work. J Electromyogr Kinesiol, 1996quem mais cita →
- 2G-A Hansson, I Balogh, K Ohlsson e mais 3. Physical workload in various types of work: Part I. Wrist and forearm. Int J Ind Ergon, 2008quem mais cita →
- 3BP Bernard. Musculoskeletal Disorders and Workplace Factors. A Critical Review of Epidemiologic Evidence for Work-Related Musculoskeletal Disorders of the Neck, Upper Extremity, and Low Back. DHHS (NIOSH)quem mais cita →
- 4LH Barbosa e HJCG Coury. Análise dos movimentos de punho nas atividades de ultra-sonografia: um estudo de caso. Rev Bras Fisioter, 2003quem mais cita →
- 5KA Mann, FW Werner e AK Palmer. Frequency spectrum analysis of wrist motion for activities of daily living. J Orthop Res, 1989quem mais cita →
- 6SA Sölveborn e C Olerud. Radial epicondylalgia (tennis elbow): measurement of range of motion of the wrist and the elbow. J Orthop Sports Phys Ther, 1996quem mais cita →
- 7G-Å Hansson, I Balogh, K Ohlsson e mais 1. Measurement of wrist and forearm positions and movements: effect of, and compensation for, goniometer crosstalk. J Electromyogr Kinesiol, 2004quem mais cita →
- 8G-A Hansson, I Balogh, JU Byström e mais 3. Questionnaire versus direct technical measurements in assessing postures and movements of the head, upper back, arms and hands. Scand J Work Environ Health, 2001quem mais cita →
- 9B Juul-Kristensen, G-Å Hansson, N Fallentin e mais 2. Assessment of work postures and movements using a video-based observation method and direct technical measurements. Appl Ergon, 2001quem mais cita →
- 10L Tesio, M Monzani, R Gatti e mais 1. Flexible electrogoniometers: kinesiological advantages with respect to potentiometric goniometers. Clin Biomech (Bristol, Avon), 1995quem mais cita →
- 11P Spielholz. Development of an electrogoniometer calibration procedure for the measurement of wrist angle and forearm rotation. Advances in Occupational Ergonomics and Safety, 1998quem mais cita →
- 12PJ Rowe, CM Myles, SJ Hillmann e mais 1. Validation of flexible electrogoniometry as a measure of joint kinematics. Physiotherapy, 2001quem mais cita →
- 13N Campbell-Kyureghyan, M Jorgensen, D Burr e mais 1. The prediction of lumbar spine geometry: method development and validation. Clin Biomech (Bristol, Avon), 2005quem mais cita →
- 14G Legnani, B Zappa, F Casolo e mais 2. A model of an electro-goniometer and its calibration for biomechanical applications. Med Eng Phys, 2000quem mais cita →
- 15C Moriguchi, TO Sato e HJCG Coury. Ankle movements during normal gait evaluated by flexible electrogoniometer. Rev Bras Fisioter, 2007no acervo →
- 16PR Poletto, TO Sato, L Carnaz e mais 2. Do individuals who present a static diference between the knees also present a diference during gait?. Rev Bras Fisioter, 2007quem mais cita →
- 17E Maupas, J Paysant, AM Datie e mais 2. Functional asymmetries of the lower limbs: A comparison between clinical assessment of laterality, isokinetic evaluation and electrogoniometric monitoring of knees during walking. Gait Posture, 2002quem mais cita →
- 18L Carnaz, AB Oliveira, TO Sato e mais 2. Effects of sensor, trials and knee joint variables on electrogoniometric gait recordings. Rev Bras Fisioter, 2008no acervo →
- 19P Jonsson e PW Johnson. Comparison of measurement accuracy between two types of wrist goniometer systems. Appl Ergon, 2001quem mais cita →
- 20B Buchholz e H Wellman. Practical operation of a biaxial goniometer at the wrist joint. Hum Factors, 1997quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda