Brazilian Journal of Physical Therapy2007

Ankle movements during normal gait evaluated by flexible electrogoniometer

CS Moriguchi, TO Sato e HJC Gil Coury

em inglês

citado por 1 artigocita 22 obras

resumo

OBJECTIVE: To evaluate ankle movements of healthy individuals walking on a treadmill, by means of a flexible electrogoniometer. METHOD: Dorsiflexion and plantar flexion and eversion/inversion movements were recorded for 90 seconds at a velocity of 5.0 km/h. Ten healthy young men of mean age 21.4 ± 2.99 years and mean height 1.62 ± 0.22 meters took part in this study. The data were analyzed descriptively (mean, standard deviation, maximum and minimum). In the sagittal plane, the gait cycle was analyzed at three times, taking the movement peaks: foot flat (FF), midstance (M) and toe off (TO). The inversion and eversion angles corresponding to these phases were identified, as well as movement peaks during gait cycles. Inter and intra-subject coefficients of variability (CV) were calculated. RESULTS: The mean values for the sagittal plane, for the left and right ankles were, respectively: 7º and 4º at FF, 2º and 7º at M, and 24º and 19º at TO. For the frontal plane, the results were inversion of 5º and 3º FF, 4º and 5º at M, and 15º and 16º at TO. The peak values were inversion of 17º and 18º and eversion of 1º. The maximum intra-subject CV was 0.39, and the maximum inter-subject CV was 0.44. CONCLUSION: The results obtained from the electrogoniometer were relatively similar to data reported in the literature for the sagittal plane, but not for the frontal plane. The discrepancies between studies measuring ankle movements suggest the need for standardization of the recording procedures.

como citar · ABNT NBR 6023

MORIGUCHI, CS; SATO, TO; GIL COURY, HJC. Ankle movements during normal gait evaluated by flexible electrogoniometer. Brazilian Journal of Physical Therapy, 2007. DOI: 10.1590/S1413-35552007000300006.

Referências

22 obras citadas

  1. 1G Wu, S Segler, P Allard e mais 3. ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion. J Biomech, 2002quem mais cita →
  2. 2VT Inman, HJ Ralston e F. Todd. Human locomotion. Human walking, 1994
  3. 3D. Tiberio. Evaluation of functional ankle dorsiflexion using subtalar neutral position: a clinical report. Phys Ther., 1987quem mais cita →
  4. 4Tesio, M Monzani, R Gatti e mais 1. Flexible electro-goniometers: kinesiological advantages with respect to potentiometric goniometers. Clin Biomech., 1995quem mais cita →
  5. 5PJ Rowe, CM Myles, SJ Hillmann e mais 1. Validation of flexible electrogoniometry as a measure of joint kinematics. Physiotherapy, 2001quem mais cita →
  6. 6P Ball e GR. Johnson. Reliability of hindfoot goniometry when using a flexible electrogoniometer. Clin Biomech, 1993quem mais cita →
  7. 7P Ball e GR. Johnson. Technique for the measurement of hindfoot inversion and eversion and its use to study a normal population. Clin Biomech., 1996quem mais cita →
  8. 8A Shiratsu e HJCG Coury. Reliability and accuracy of different sensors of a flexible electrogoniometer. Clin Biomech, 2003quem mais cita →
  9. 9DA. Winter. Kinematic and kinetic patterns in human gait: variability and compensating effects. Hum Mov Sci., 1984quem mais cita →
  10. 10M Locke, J Perry, J Campbell e mais 1. Ankle and subtalar motion during gait in arthritic patients. Phys Ther., 1984quem mais cita →
  11. 11J Isacson, L Gransberg e E. Knutsson. Three-dimensional electrogoniometric gait recording. J Biomech., 1986quem mais cita →
  12. 12L Moseley, R Smith, A Hunt e mais 1. Three-dimensional kinematics of the rearfoot during the stance phase of walking in normal young adult males. Clin Biomech., 1996quem mais cita →
  13. 13W Liu, S Siegler, H Hillstrom e mais 1. Three-dimensional, six-degrees-of-freedom kinematics of the human hindfoot during the stance phase of level walking. Hum Mov Sci., 1997quem mais cita →
  14. 14MG Benedetti, F Catani, A Leardini e mais 2. Data management in gait analysis for clinical applications. Clin Biomech, 1998quem mais cita →
  15. 15A Leardini, MG Benedetti, F Catani e mais 2. An anatomically based protocol for the description of foot segment kinematics during gait. Clin Biomech., 1999quem mais cita →
  16. 16JR Nymark, SJ Balmer, EH Melis e mais 2. Electromyographic and kinematic nondisabled gait differences at extremely slow overgroung and treadmill walking speeds. J Rehab Res Dev., 2005quem mais cita →
  17. 17G-Å Hansson, I Balogh, K Ohlsson e mais 1. Measurement of wrist and forearm positions and movements: effect of, and compensation for, goniometer crosstalk. J Electromyogr Kinesiol., 2004quem mais cita →
  18. 18S Zografos, B Chaminade, MC Hobatho e mais 1. Experimental study of the subtalar joint axis preliminary investigation. Surg Radiol Anat., 2000quem mais cita →
  19. 19A Leardini, R Stagni e JJ O'Connor. Mobility of the subtalar joint in the intact ankle complex. J Biomech., 2001quem mais cita →
  20. 20American Medical Association. Range of motion assessment: the practical guide to range of motion assessment. 2002quem mais cita →
1–20 de 22 obras citadas

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

4 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações