resumo

The Guidelines Project, an initiative of the Brazilian Medical Association, aims to combine information from the medical field to standardize how to conduct, and to assist in the reasoning and decision-making of doctors. The information provided by this project must be critically evaluated by the physician responsible for the conduct that will be adopted, depending on the conditions and the clinical condition of each patient.

como citar · ABNT NBR 6023

SPIR, Ighor Alexander Zamuner et al. Comparison between ceramic-on-polyethylene versus metal-on-polyethylene prostheses in Total Hip Arthroplasties: a systematic review and meta-analysis. Revista da Associação Médica Brasileira, 2022. DOI: 10.1590/1806-9282.022D6812.

Referências

30 obras citadas · 1 no acervo

  1. 1CR Galia, CV Diesel, MR Guimarães e mais 1. Total hip arthroplasty: a still evolving technique. Rev Bras Ortop., 2017no acervo →
  2. 2Cochrane. Review Manager (RevMan). 2014quem mais cita →
  3. 3SP Hozo, B Djulbegovic e I Hozo. Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol., 2005quem mais cita →
  4. 4Evidence Prime Inc. McMaster University. GRADEpro GDT: GRADEpro Guideline Development Tool [Software]. 2015quem mais cita →
  5. 5OB Gosling, TG Ferreri, A Khoshbin e mais 2. A systematic review and meta-analysis of survivorship and wear rates of metal and ceramic heads articulating with polyethylene liners in total hip arthroplasty. Hip Int., 2020quem mais cita →
  6. 6AT Hexter, SM Hislop, GW Blunn e mais 1. The effect of bearing surface on risk of periprosthetic joint infection in total hip arthroplasty: a systematic review and meta-analysis. Bone Joint J, 2018quem mais cita →
  7. 7JA López-López, RL Humphriss, AD Beswick e mais 3. Choice of implant combinations in total hip replacement: systematic review and network meta-analysis. BMJ, 2017quem mais cita →
  8. 8YH Kim, JS Kim e SH Cho. A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. A prospective, randomised study. J Bone Joint Surg Br., 2001quem mais cita →
  9. 9J Dahl, P Söderlund, B Nivbrant e mais 2. Less wear with aluminium-oxide heads than cobalt-chrome heads with ultra-high molecular weight cemented polyethylene cups: a ten-year follow-up with radiostereometry. Int Orthop., 2012quem mais cita →
  10. 10A Atrey, JI Wolfstadt, N Hussain e mais 3. The ideal total hip replacement bearing surface in the young patient: a prospective randomized trial comparing alumina ceramic-on-ceramic with ceramic-on-conventional polyethylene: 15-year follow-up. J Arthroplasty, 2018quem mais cita →
  11. 11PA Vendittoli, M Shahin, C Rivière e mais 3. Hip resurfacing compared with 28-mm metal-on-metal total hip replacement: a randomized study with 15 years of follow-up. J Bone Joint Surg Am., 2020quem mais cita →
  12. 12JA D’Antonio, WN Capello e R Ramakrishnan. Second-generation annealed highly cross- linked polyethylene exhibits low wear. Clin Orthop Relat Res., 2012quem mais cita →
  13. 13B Zerahn, L Borgwardt, S Ribel-Madsen e mais 1. A prospective randomized study of periprosthetic femoral bone remodeling using four different bearings in hybrid total hip arthroplasty. Hip Int., 2011quem mais cita →
  14. 14JA D’Antonio, MT Manley, WN Capello e mais 3. Five-year experience with crossfire highly cross-linked polyethylene. Clin Orthop Relat Res., 2005quem mais cita →
  15. 15J Dahl, F Snorrason, L Nordsletten e mais 1. More than 50% reduction of wear in polyethylene liners with alumina heads compared to cobalt-chrome heads in hip replacements: a 10-year follow-up with radiostereometry in 43 hips. Acta Orthop., 2013quem mais cita →
  16. 16K Bjorgul, WN Novicoff, ST Andersen e mais 3. High rate of revision and a high incidence of radiolucent lines around Metasul metal-on-metal total hip replacements: results from a randomised controlled trial of three bearings after seven years. Bone Joint J., 2013quem mais cita →
  17. 17K Ise, K Kawanabe, J Tamura e mais 3. Clinical results of the wear performance of cross-linked polyethylene in total hip arthroplasty: prospective randomized trial. J Arthroplasty, 2009quem mais cita →
  18. 18SS Jassim, S Patel, N Wardle e mais 3. Five-year comparison of wear using oxidized zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial. Bone Joint J, 2015quem mais cita →
  19. 19BA Jonsson, T Kadar, LI Havelin e mais 3. Oxinium modular femoral heads do not reduce polyethylene wear in cemented total hip arthroplasty at five years: a randomised trial of 120 hips using radiostereometric analysis. Bone Joint J., 2015quem mais cita →
  20. 20T Kadar, G Hallan, A Aamodt e mais 3. Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: a randomized radiostereometric study of 150 patients. JOrthop Res., 2011quem mais cita →
1–20 de 30 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações