Brazilian Journal of Physics2009
Paramagnetic shimming for high-field MRI
em inglês
resumo
The diamagnetism of biological tissues reduces the homogeneity of the magnetic field and may limit the number of samples in multi-sample gradient-recalled echo (GRE) experiments. This study aims to 1) evaluate the magnetic field distortions and signal loss artifacts in GRE images of proximal water samples, and 2) develop a passive shimming device to overcome this limitation. The magnetic field distribution produced by a diamagnetic H2O sphere and a paramagnetic CuSO4 disk in a secondary phantom were mapped using GRE experiments and the phase reference method, and compared to the corresponding magnetostatics models. The water sphere produced a pronounced signal loss artifact in amplitude images. This artifact was significantly reduced when the paramagnetic disk was placed symmetrically between the water sphere and the secondary spherical phantom. The present study suggests that the use of paramagnetic shimming devices can help to minimize susceptibility-related MRI signal losses and to increase the number of samples in multi-sample MRI experiments. The volume susceptibility and the shape of paramagnetic shimming devices could be optimized for particular setups and samples accordingly.
como citar · ABNT NBR 6023
TOMASI, D.; WANG, R.L. Paramagnetic shimming for high-field MRI. Brazilian Journal of Physics, 2009. DOI: 10.1590/S0103-97332009000300008.
Referências
15 obras citadas
- 1T Truong, B Clymer, D Chakeres e mais 1. Three-dimensional numerical simulations of susceptibility-induced magnetic field inhomogeneities in the human head. Magn Reson Imaging, 2002quem mais cita →
- 2S Li, GD Williams, TA Frisk e mais 2. A computer simulation of the static magnetic field distribution in the human head. Magn Reson Med, 1995quem mais cita →
- 3S Li, BJ Dardzinski, CM Collins e mais 2. Three-dimensional mapping of the static magnetic field inside the human head. Magn Reson Med, 1996quem mais cita →
- 4J Schenck. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys, 1996quem mais cita →
- 5K Koch, P Brown, D Rothman e mais 1. Sample-specific diamagnetic and paramagnetic passive shimming. J Magn Reson, 2006quem mais cita →
- 6J Wilson, M Jenkinson e P Jezzard. Optimization of static field homogeneity in human brain using diamagnetic passive shims. Magn Reson Med, 2002quem mais cita →
- 7J Wilson, M Jenkinson e P Jezzard. Protocol to determine the optimal intraoral passive shim for minimisation of susceptibility artifact in human inferior frontal cortex. Neuroimage, 2003quem mais cita →
- 8N Bock, N Konyer e R Henkelman. Multiple-mouse. MRI Magn Reson Med, 2003
- 9J Dazai, N Bock, B Nieman e mais 3. Multiple mouse biological loading and monitoring system for. MRI Magn Reson Med, 2004quem mais cita →
- 10A Haase, J Frahm, W Hanicke e mais 1. FLASH imaging: Rapid NMR imaging using low flip angle pulses. J Magn Reson, 1986quem mais cita →
- 11D Tomasi, H Panepucci, EL Vidoto e mais 1. Use of a phase reference for field mapping with amplitude images at low field. J Magn Reson, 1998quem mais cita →
- 12D Tomasi e H Panepucci. Magnetic field mapping with the phase reference method. Magn Reson Imag, 1999quem mais cita →
- 13JD Jackson. Classical Electrodynamics. 1965quem mais cita →
- 14J Schenck. Safety of strong, static magnetic fields. J Magn Res Imaging, 2000quem mais cita →
- 15D Tomasi e E Caparelli. Macrovascular contribution in activation patterns of working memory. J Cereb Blood Flow Metab, 2007quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda