Revista Brasileira de Oftalmologia2018

Analysis between two optical biometric devices in patients with cataract

Francisco Wellington Rodrigues, Luiz Alberto Rosa Barbalho, Marcus Vinícius Batista Machado, Cícero Ricarte Bezerra e Rodrigo Egídio da Silva

em inglês

citado por 1 artigocita 22 obras, 2 no acervo

resumo

ABSTRACT Objective: To evaluate the correlation of optical biometry and target with variable ages, anterior chamber depth, axial length, R1/K1 and R2/K2 established by two optical biometry devices in patients with cataract. Methods: The study included the analysis of 348 medical records, from which 503 cataract eyes were selected, which underwent evaluation by the optical biometric devices IOL Master 700 and Lenstar LS 900 in the period of April to July 2017. Data collected were: age, anterior chamber depth, axial length, R1/K1 and R2/K2. Results: The average of the biometrics obtained using Lenstar was 21.02, varying 3.46, more or less, with an average target of -0.02, varying 0.45. In relation to the IOL Master it was 21.19, with a variation of 3.40 and average target of -0.01, a variation of 0.11. It can be observed that despite close values in relation to the mean, there was significance (p<0.001). Axial length (p<0.001) and R1/K1 (p<0.001) had an influence on the difference of the biometric values between the devices. Conclusion: A high degree of clinical and statistical correspondence was observed between the results obtained by the biometry devices in patients with cataract.

como citar · ABNT NBR 6023

RODRIGUES, Francisco Wellington et al. Analysis between two optical biometric devices in patients with cataract. Revista Brasileira de Oftalmologia, 2018. DOI: 10.5935/0034-7280.20180040.

Referências

22 obras citadas · 2 no acervo

  1. 1World Health Organization. Global Data on Visual Impairments 2010. 2012quem mais cita →
  2. 2C Zetterström, A Behndig, M Kugelberg e mais 2. Changes in intraocular pressure after cataract surgery: analysis of the Swedish National Cataract Register Data. J Cataract Refract Surg, 2015quem mais cita →
  3. 3M Ávila, MR Alves e M Nishi. Condições de Saúde Ocular no Brasil. 2015quem mais cita →
  4. 4B Bowling. Kanski’s clinical ophthalmology. 2016quem mais cita →
  5. 5T Root. Lens and cataract. Am Acad Ophthalmol, 2011
  6. 6Royal National Institute of Blind People. Understanding cataracts. Eye J R Coll Ophthalmol, 2014quem mais cita →
  7. 7BM Fontes, BM Fontes e E Castro. Intraocular lens power calculation by measuring axial length with partial optical coherence and ultrasonic biometry. Arq Bras Oftalmol, 2011no acervo →
  8. 8A Sahin e P Hamrah. Clinically relevant biometry. Curr Opin Ophthalmol, 2012quem mais cita →
  9. 9J Zhao, Z Chen, Z Zhou e mais 2. Evaluation of the repeatability of the Lenstar and comparison with two other non-contact biometric devices in myopes. Clin Exp Optom, 2013quem mais cita →
  10. 10SR Choi e US Kim. The correlation between angle kappa and ocular biometry in Koreans. Korean J Ophthalmol, 2013quem mais cita →
  11. 11H Hashemi, E Jafarzadehpur, S Ghaderi e mais 3. Ocular components during the ages of ocular development. Acta Ophthalmol, 2015quem mais cita →
  12. 12IdS Yamane. Avaliação de parâmetros tomográficos de córnea e segmento anterior e de variáveis desencadeadas pela resposta ocular à tonometria de não contato [tese]. 2012quem mais cita →
  13. 13G Kaswin, A Rousseau, M Mgarrech e mais 2. Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard. J Cataract Refract Surg, 2014quem mais cita →
  14. 14HB Pant, S Bandyopadhyay, N John e mais 2. Differential cataract blindness by sex in India: evidence from two large national surveys. Indian J Ophthalmol, 2017quem mais cita →
  15. 15TK Yoo, MJ Choi, HK Lee e mais 3. Comparison of ocular biometry and refractive outcomes using IOL Master 700, IOL Master 500, and ultrasound. J Korean Ophthalmol Soc, 2017quem mais cita →
  16. 16J Plat, D Hoa, F Mura e mais 3. Clinical and biometric determinants of actual lens position after cataract surgery. J Cataract Refract Surg, 2017quem mais cita →
  17. 17J Crispim, R Nose, AC Garcia e mais 2. Clinical experience with the first 40 cases with femtosecond laser cataract surgery technology: safety of the learning curve. Rev Bras Oftalmol, 2015no acervo →
  18. 18S Goebels, M Pattmöller, T Eppig e mais 3. Comparison of 3 biometry devices in cataract patients. J Cataract Refract Surg, 2015quem mais cita →
  19. 19LP Cruysberg, M Doors, F Verbakel e mais 3. Evaluation of the Lenstar LS 900 non-contact biometer. Br J Ophthalmol, 2010quem mais cita →
  20. 20PJ Buckhurst, JS Wolffsohn, S Shah e mais 3. A new optical low coherence reflectometry device for ocular biometry in cataract patients. Br J Ophthalmol, 2009quem mais cita →
1–20 de 22 obras citadas

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

6 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações