Arquivos Brasileiros de Oftalmologia2014
A new unity for angular measurements in strabismus
em inglês
citado por 2 artigoscita 4 obras, 1 no acervo
resumo
The practical advantages of quantifying an angle by a ratio of linear lengths instead of arcs of circles has led to the definition of the prism-diopter, a conventional unity for numbering prisms and measuring strabismic deviations. However, a major inconvenience of using prism-diopter unities to express angular measurements is the non-linearity of the scale, which reaches an infinite value for the angle of 90º, then becomes negative, with decreasing magnitudes for increasing angles between 90º and 180º. As a consequence, arithmetical operations and comparisons of angles measured by such unities present errors of very great magnitudes. In order to retain the advantages of defining an angle by straight line dimensions but to diminish the severe inconveniences of this method, a new definition of the prism-diopter is proposed. Here, instead of defining the prism-diopter by the asymmetrical condition, the conception of this new unity is based on a geometrically symmetrical condition; that of the relationship of an isosceles triangle (where the leg is perpendicular to the bisector of the angle and the bisector itself ). The condition of symmetry for the definition of the new unity represents a conceptual advance because it reproduces the already well accepted, conventional criteria for quantifying the value of a prism, that of its minimum deviation. Furthermore, it corresponds to the most commonly observed clinical conditions of binocular balance. The absolute differences between the unitary values of the prism-diopter and that of the new unity are negligible (0.0025%), but the scale of values expressed by the new unity is closer to the ideal scale of angular measurements. (With the new unity, the infinite value is only reached for an angle of 180º and the errors due to arithmetical operations are much smaller.) Numerical examples showing the advantages of using the new unity of angular measurements instead of the prism-diopter are presented. A mathematical generalization of the modifying concept (partition of an angle) with which the new unity is based is also provided.
como citar · ABNT NBR 6023
BICAS, Harley E. A. A new unity for angular measurements in strabismus. Arquivos Brasileiros de Oftalmologia, 2014. DOI: 10.5935/0004-2749.20140070.
Referências
4 obras citadas · 1 no acervo
- 1CF Prentice. A metric system of numbering and measuring prisms. Arch Ophthalmol, 1890quem mais cita →
- 2WS Dennett. A new method of numbering prisms. Trans Am Ophthalmol Socquem mais cita →
- 3HEA Bicas. Unidades de medida. Estrabismo, 2008
- 4HEA Bicas. Estrabismos: da teoria à prática, dos conceitos às suas operacionalizações. Arq Bras Oftalmol, 2009no acervo →
Quem cita esta obra
2 artigos do acervo
- 2025: citada em 1 artigo
- 2026: citada em 1 artigo
quem fala desta obra
1 pessoa- Harley E. A. Bicasautocitação2 artigos · 2026
os artigos
- A trilogy of the oculomotor system Part II - active, passive, and dissipative forces Part III - diagnostic testsHarley E. A. Bicas · Arquivos Brasileiros de Oftalmologia · 2026
- A trilogy of the oculomotor system: Part I: Ocular movements, finalities, and measurementsHarley E. A. Bicas · Arquivos Brasileiros de Oftalmologia · 2025
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda