Arquivos Brasileiros de Oftalmologia2010

Glaucoma anterior chamber morphometry based on optical Scheimpflug images

Ruiz Simonato Alonso, Renato Ambrósio Junior, Augusto Paranhos Junior, Lisandro Massanori Sakata e Marcelo Palis Ventura

em inglês

citado por 1 artigocita 32 obras

resumo

Purpose: To compare the performance of gonioscopy and noncontact morphometry with anterior chamber tomography (High Resolution Pentacam - HR) using optical Scheimpflug images in the evaluation of the anterior chamber angle (ACA). Methods: Transversal study. 112 eyes from 74 subjects evaluated at the Glaucoma Department, Fluminense Federal University, underwent gonioscopy and Pentacam HR. Using gonioscopy, the ACA was graded using the Shaffer Classification (SC) by a single experienced examiner masked to the Pentacam HR findings. Narrow angle was determined in eyes in which the posterior trabecular meshwork could not be seen in two or more quadrants on non-indentation gonioscopy (SC Grade 2 or less). Pentacam HR images of the nasal and temporal quadrants were evaluated by custom software to automatically obtain anterior chamber measurements, such as: anterior chamber angle (ACA), anterior chamber volume (ACV) and anterior chamber depth (ACD). Results: Based on gonioscopy results, 74 (60.07%) eyes of patients classified as open-angle (SC 3 and 4) and 38 (33.93%) eyes of patients classified as narrow-angle (SC 1 and 2). Noncontact morphometry with Scheimpflug images revealed a mean ACA of 39.20 ± 5.31 degrees for open-angle and 21.18 ± 7.98 degrees for narrow-angle. The open-angle group showed significant greater ACV and ACD values when compared to narrow-angle group (ACV of 193 ± 36 mm³ vs. 90 ± 25 mm³, respectively, p<0.001; and ACD of 3,09 ± 0,42 mm vs. 1,55 ± 0,64 mm, respectively, p<0.0001.). In screening eyes with open-angle and narrow-angle with the Pentacam ACA of 20º (SC Grade 2) using the ROC curves, the analysis showed 52.6% of sensitivity and 100% of specificity. Conclusions: The Pentacam showed ability in detecting eyes at risk for angle closure analyzing ACV and ACD.

como citar · ABNT NBR 6023

ALONSO, Ruiz Simonato et al. Glaucoma anterior chamber morphometry based on optical Scheimpflug images. Arquivos Brasileiros de Oftalmologia, 2010. DOI: 10.1590/S0004-27492010000600005.

Referências

32 obras citadas

  1. 1HA Quigley. Number of people with glaucoma worldwide. Br J Ophthalmol, 1996quem mais cita →
  2. 2AL Coleman. Glaucoma. Lancet, 1999
  3. 3RN Shaffer e A Schwartz. Gonioscopy. Surv Ophthalmol, 1957
  4. 4RN Shaffer. Primary glaucomas: Gonioscopy, ophthalmoscopy and perimetry. Trans Am Acad Ophthalmol Otolaryngol, 1960quem mais cita →
  5. 5SF Riley, JP Nairn, FA Maestre e mais 1. Analysis of the anterior chamber angle by gonioscopy and by ultrasound biomicroscopy. Int Ophthalmol Clin, 1994quem mais cita →
  6. 6RY Chan, JA Smith e KT Richardson. Anterior segment configuration correlated with Shaffer's grading of anterior chamber angle. Arch Ophthalmol, 1981quem mais cita →
  7. 7YY Kim e HR Jung. Clarifying the nomenclature for primary angle-closure glaucoma. Surv Ophthalmol, 1997quem mais cita →
  8. 8CA Bruno e WL Alward. Gonioscopy in primary angle closure glaucoma. Semin Ophthalmol, 2002quem mais cita →
  9. 9NG Congdon, GL Spaeth, J Augsburger e mais 3. A proposed simple method for measurement in the anterior chamber angle: biometric gonioscopy. Ophthalmology, 1999quem mais cita →
  10. 10PJ Foster, J Baasanhu, PH Alsbirk e mais 3. Glaucoma in Mongolia: A population-based survey in Hövsgöl province, northern Mongolia. Arch Ophthalmol, 1996quem mais cita →
  11. 11PJ Foster e GJ Johnson. Glaucoma in China: how big is the problem?. Br J Ophthalmol, 2001quem mais cita →
  12. 12GL Spaeth. The normal development of the human anterior chamber angle: a new system of descriptive grading. Trans Ophthalmol Soc U K, 1971quem mais cita →
  13. 13GL Spaeth, S Aruajo e A Azuara. Comparison of the configuration of the human anterior chamber angle, as determined by the Spaeth gonioscopic grading system and ultrasound biomicroscopy. Trans Am Ophthalmol Soc, 1995quem mais cita →
  14. 14H Hoerauf, C Wirbelauer, C Scholz e mais 4. Slit-lamp-adapted optical coherence tomography of the anterior segment. Graefes Arch Clin Exp Ophthalmol, 2000quem mais cita →
  15. 15W Van Herick, RN Shaffer e A Schwartz. Estimation of width of angle of anterior chamber: Incidence and significance of the narrow angle. Am J Ophthalmol, 1969quem mais cita →
  16. 16CJ Pavlin, K Harasiewicz, MD Sherar e mais 1. Clinical use of ultrasound biomicroscopy. Ophthalmology, 1991quem mais cita →
  17. 17CJ Pavlin, K Harasiewicz e FS Foster. Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes. Am J Ophthalmol, 1992quem mais cita →
  18. 18GL Spaeth, A Azuara-Blanco, SV Araujo e mais 1. Intraobserver and interobserver agreement in evaluating the anterior chamber angle configuration by ultrasound biomicroscopy. J Glaucoma, 1997quem mais cita →
  19. 19C Allouch, O Touzeau, V Borderie e mais 4. Orbscan: a new device for iridocorneal angle measurement. J Fr Ophtalmol, 2002quem mais cita →
  20. 20B Lackner, G Schmidinger e C Skorpik. Validity and repeatability of anterior chamber depth measurements with Pentacam and Orbscan. Optom Vis Sci, 2005quem mais cita →
1–20 de 32 obras citadas

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

7 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações