Arquivos Brasileiros de Oftalmologia2009

Comparative biometric study between plateau iris configuration and primary open angle glaucoma with narrow angle

Alberto Diniz Filho, Sebastião Cronemberger, Rafael Vidal Mérula e Nassim Calixto

em inglês

citado por 1 artigocita 23 obras, 1 no acervo

resumo

PURPOSE: To investigate biometrically the differences between plateau iris configuration (PIC) eyes and primary open angle glaucoma with narrow angle eyes. METHODS: A comparative study involving a case series with 20 eyes of 11 plateau iris configuration patients and 45 eyes of 27 primary open angle glaucoma with narrow angle eyes patients was done. The following measurements were taken: corneal curvature, central corneal thickness, anterior chamber depth, lens thickness (LT), axial length (AL), lens thickness and axial length ratio, lens position (LP) and relative lens position (RLP). RESULTS: The plateau iris configuration eyes presented a higher corneal cuvature value than primary open angle glaucoma with narrow angle eyes eyes but not with clinical and statistical difference (P=0.090). The plateau iris configuration eyes demonstrated a higher central corneal thickness, with statistical significance, when compared to primary open angle glaucoma with narrow angle eyes (P=0.010). Statistical significant difference between plateau iris configuration and primary open angle glaucoma with narrow angle eyes was found in axial length (21.69 ± 0.98 vs. 22.42 ± 0.89; P=0.003). No significant difference was found when anterior chamber depth (2.62 ± 0.23 vs. 2.71 ± 0.31; P=0.078), LT (4.67 ± 0.36 vs. 4.69 ± 0.45; P=0.975), LT/AL (2.16 ± 0.17 vs. 2.10 ± 0.21; P=0.569), LP (4.95 ± 0.25 vs. 5.06 ± 0.34; P=0.164) and RLP (0.23 ± 0.01 vs. 0.22 ± 0.14; P=0.348) were evaluated. CONCLUSION: The eyes with plateau iris configuration presented statistical significantly shorter axial length and higher central corneal thickness than primary open angle glaucoma with narrow angle eyes.

como citar · ABNT NBR 6023

DINIZ FILHO, Alberto et al. Comparative biometric study between plateau iris configuration and primary open angle glaucoma with narrow angle. Arquivos Brasileiros de Oftalmologia, 2009. DOI: 10.1590/S0004-27492009000300005.

Referências

23 obras citadas · 1 no acervo

  1. 1HS Gradle e HS Sugar. Concerning the chamber angle: III. A clinical method of goniometry. Am J Ophthalmol, 1940quem mais cita →
  2. 2R Törnquist. Angle-closure glaucoma in an eye with a plateau type of iris. Acta Ophthalmol, 1958quem mais cita →
  3. 3M Wand, WM Grant, RJ Simmons e mais 1. Plateau iris syndrome. Trans Sect Ophthalmol Am Acad Ophthalmol Otolaryngol, 1977quem mais cita →
  4. 4RF Lowe. Plateau iris. Aust J Ophthalmol, 1981
  5. 5RN Shaffer. Primary glaucomas. Gonioscopy, ophthalmoscopy and perimetry. Trans Am Acad Ophthalmol Otolaryngol, 1960quem mais cita →
  6. 6R Ritch. Plateau iris is caused by abnormally positioned ciliary processes. J Glaucoma, 1992quem mais cita →
  7. 7LT Jr Chylack, MC Leske, D McCarthy e mais 3. Lens Opacities Classification System II (LOCS II). Arch Ophthalmol, 1989quem mais cita →
  8. 8R Ritch, BM Chang e JM Liebmann. Angle-closure in younger patients. Ophthalmology, 2003quem mais cita →
  9. 9R Stieger, C Kniestedt, F Sutter e mais 2. Prevalence of plateau iris syndrome in young patients with recurrent angle-closure. Clin Experiment Ophthalmol., 2007quem mais cita →
  10. 10R Ritch e S Dorairaj. Plateau iris syndrome in younger patients. Clin Experiment Ophthalmol., 2007quem mais cita →
  11. 11RF Lowe. Causes of shallow anterior chamber in primary angle-closure glaucoma: Ultrasonic biometry of normal and angle-closure glaucoma eyes. Am J Ophthalmol, 1969quem mais cita →
  12. 12SN Markowitz e JD Morin. The ratio of lens thickness to axial length for biometric standardization in angle-closure glaucoma. Am J Ophthalmol, 1985quem mais cita →
  13. 13WC Panek, RE Christensen, DA Lee e mais 3. Biometric variables in patients with occludable anterior chamber angles. Am J Ophthalmol, 1990quem mais cita →
  14. 14RF Lowe. Aetiology of the anatomical basis for primary angle-closure glaucoma. Biometrical comparisons between normal eyes and eyes with primary angle-closure glaucoma. Br J Ophthalmol, 1970quem mais cita →
  15. 15N Calixto e Cronemberger. Glaucoma simples x glaucoma agudo: estudo ecobiométrico. Arq Bras Oftalmol, 1986quem mais cita →
  16. 16RV Mérula, S Cronemberger, A Diniz Filho e mais 1. Análise morfométrica comparativa entre olhos com glaucoma agudo primário e olhos contralaterais. Arq Bras Oftalmol, 2008no acervo →
  17. 17DA Lee, RF Brubaker e DM Ilstrup. Anterior chamber dimensions in patients with narrow angles and angle-closure glaucoma. Arch Ophthalmol, 1984quem mais cita →
  18. 18R Sihota, NC Lakshmaiah, HC Agarwal e mais 2. Ocular parameters in the subgroups of angle closure glaucoma. Clin Experiment Ophthalmol, 2000quem mais cita →
  19. 19MA Mandell, CJ Pavlin, DJ Weisbrod e mais 1. Anterior chamber depth in plateau iris syndrome and pupillary block as measured by ultrasound biomicroscopy. Am J Ophthalmol, 2003quem mais cita →
  20. 20PS Li, JS Lai e DS Lam. Anterior chamber depth in plateau iris syndrome and pupillary block as measured by ultrasound biomicroscopy. Am J Ophthalmol., 2004quem mais cita →
1–20 de 23 obras citadas

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

3 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações