Arquivos Brasileiros de Oftalmologia2009

Does the apodized diffractive intraocular lens Acrysof ReSTOR NaturalTM interfere with FDT Matrix perimetry results?

Karine Duarte Bojikian, João Brasil Vita, Catia Potira Dal Forno, Alfredo Tranjan Neto e Christiane Rolim de Moura

em inglês

cita 28 obras

resumo

PURPOSE: To compare the effect of an apodized diffractive intraocular lens (IOL) (Acrysof ReSTOR NaturalTM) and its yellow counterpart (Natural IQ TM) on frequency doubling technology (FDT) perimetry results. METHODS: This study included 37 eyes from 22 patients at the "Centro Oftalmológico Tranjan" who had undergone uncomplicated phacoemulsification and intraocular lens implantation (17 Acrysof ReSTOR NaturalTM, 20 Natural IQ TM) performed by the same surgeon, at least three months prior to the study. Patients were subject to frequency doubling technology Matrix Perimeter testing. RESULTS: The patients were between 41 to 79 years old (mean, 70.78 ± 9.83) in the Natural IQ TM and 49 to 81 years old (mean, 67.11± 11.48) in the Acrysof ReSTOR NaturalTM group, and the mean IOP was 13.64 ± 2.02 mmHg in the Natural IQ TM 12.94 ± 1.39 mmHg in the Acrysof ReSTOR NaturalTM group. The mean pupillary diameter under scotopic conditions was 6.63 ± 1.16 mm in the Natural IQ TM group and 7.20 ± 1.8 mm in the Acrysof ReSTOR NaturalTM group (p=0.20). The mean deviation was -1.83 ± 3.46 dB in the Natural IQ TM group and -1.77 ± 3.94 dB in the Acrysof ReSTOR NaturalTM group (p=0.28). The pattern standard deviation was 3.49 ± 0.79 dB in the Natural IQ TM group and 3.20 ± 0.86 dB in the Acrysof ReSTOR NaturalTM group (p=0.27). CONCLUSION: There was no difference in the results of FDT Matrix perimetry in eyes that received apodized diffractive IOLs implant or eyes that received monofocal intraocular lens implant.

como citar · ABNT NBR 6023

BOJIKIAN, Karine Duarte et al. Does the apodized diffractive intraocular lens Acrysof ReSTOR NaturalTM interfere with FDT Matrix perimetry results? Arquivos Brasileiros de Oftalmologia, 2009. DOI: 10.1590/S0004-27492009000600003.

Referências

28 obras citadas

  1. 1L Walkow e UM Klemen. Patient satisfaction after implantation of diffractive designed multifocal intraocular lenses in dependence on objective parameters. Graefes Arch Clin Exp Ophthalmol, 2001quem mais cita →
  2. 2T Kohnen, D Allen, C Boureau e mais 3. European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens. Ophthalmology, 2006quem mais cita →
  3. 3R Solomon e E Donnenfeld. Refractive intraocular lenses: multifocal and phakic IOLs. Int Ophthalmol Clin, 2006quem mais cita →
  4. 4L Lesueur, B Gajan, M Nardin e mais 2. [Comparison of visual results and quality of vision between two multifocal intraocular lenses: Multifocal silicone and bifocal PMMA]. J Fr Ophtalmol, 2000quem mais cita →
  5. 5S Pieh, H Weghaupt e C Skorpik. Contrast sensitivity and glare disability with diffractive and refractive multifocal intraocular lenses. J Cataract Refract Surg, 1998quem mais cita →
  6. 6KM Rocha, MR Chalita, CE Souza e mais 3. Postoperative wavefront analysis and contrast sensitivity of a multifocal apodized diffractive IOL (ReSTOR) and three monofocal IOLs. J Refract Surg, 2005quem mais cita →
  7. 7CE Souza, C Muccioli, ES Soriano e mais 3. Visual performance of AcrySof ReSTOR apodized diffractive IOL: a prospective comparative trial. Am J Ophthalmol, 2006quem mais cita →
  8. 8R Solomon e E Donnenfeld. Refractive Intraocular Lenses: Multifocal and Phakic IOLs. Int Ophthalmol Clin, 2006quem mais cita →
  9. 9DH Kelly. Frequency doubling in visual responses. J Opt Soc Am, 1966quem mais cita →
  10. 10WL Alward. Frequency doubling technology perimetry for the detection of glaucomatous visual field loss. Am J Ophthalmol, 2000quem mais cita →
  11. 11T Maddess, I Goldberg, J Dobinson e mais 3. Testing for glaucoma with the spatial frequency doubling illusion. Vision Res, 1999quem mais cita →
  12. 12HA Quigley. Neuronal death in glaucoma. Prog Retin Eye Res, 1999quem mais cita →
  13. 13P Brusini, ML Salvetat, M Zeppieri e mais 3. Visual field testing with the new Humphrey Matrix: a comparison between the FDT N-30 and Matrix N-30-F tests. Acta Ophthalmol Scand, 2006quem mais cita →
  14. 14N Kara-Junior, JL Jardim, E de Oliveira Leme e mais 2. Effect of the AcrySof Natural intraocular lens on blue-yellow perimetry. J Cataract Refract Surg, 2006quem mais cita →
  15. 15L Mastropasqua, P Brusini, P Carpineto e mais 3. Humphrey matrix frequency doubling technology perimetry and optical coherence tomography measurement of the retinal nerve fiber layer thickness in both normal and ocular hypertensive subjects. J Glaucoma, 2006quem mais cita →
  16. 16P Brusini. Frequency doubling technology staging system 2. J Glaucoma, 2006quem mais cita →
  17. 17J Katz. Two eyes or one?: The data analyst's dilemma. Ophthalmic Surg, 1988quem mais cita →
  18. 18CT Jr Post. Comparison of depth of focus and low-contrast acuities for monofocal versus multifocal intraocular lens patients at 1 year. Ophthalmology, 1992quem mais cita →
  19. 19H Weghaupt, S Pieh e C Skorpik. Visual properties of the foldable Array multifocal intraocular lens. J Cataract Refract Surg, 1996quem mais cita →
  20. 20T Olsen e L Corydon. Contrast sensitivity as a function of focus in patients with the diffractive multifocal intraocular lens. J Cataract Refract Surg, 1990quem mais cita →
1–20 de 28 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações