Arquivos Brasileiros de Oftalmologia2016

Comparative study on optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis ® ZMB00 and AcrySof ® IQ ReSTOR ® Multifocal IOL SN6AD1

Mario Augusto Pereira Dias Chaves, Wilson Takashi Hida, Patrick Frenzel Tzeliks, Michelle Rodrigues Gonçalves, Fernando de Bortoli Nogueira, Celso Takashi Nakano, Antonio Francisco Pimenta Motta, André Gustavo Rolim de Araújo e Milton Ruiz Alves

em inglês

cita 30 obras, 4 no acervo

resumo

ABSTRACT Purpose: To compare the optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis® ZMB00 and AcrySof® ReSTOR® SN6AD1. Methods: This prospective, non-randomized comparative study included the assessment of 74 eyes in 37 patients referred for cataract surgery and candidates for multifocal intraocular lens implants. Exclusion criteria included existence of any other eye disease, previous eye surgery, high axial myopia, preoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), and distance-corrected intermediate visual acuity (DCIVA), with analysis of contrast sensitivity (CS), wavefront, and visual defocus curve. Results: Postoperative UDVA was 0.09 and 0.08 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.868); postoperative CDVA was 0.04 and 0.02 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.68); DCIVA was 0.17 and 0.54 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.000); and DCNVA was 0.04 and 0.09 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.001). In both cases, there was an improvement in the spherical equivalent and UDVA (p<0.05). Under photopic conditions, the SN6AD1 group had better CS at low frequencies without glare (p=0.04); however, the ZMB00 group achieved better sensitivity at high frequencies with glare (p=0.003). The SN6AD1 and ZMB00 lenses exhibited similar behavior for intermediate vision, according to the defocus curve; however, the ZMB00 group showed a shorter reading distance than the SN6AD1 group. There were no significant differences regarding aberrometry between the two groups. Conclusion: Both lenses promoted better quality of vision for both long and short distances and exhibited a similar behavior for intermediate vision. The SN6AD1 and ZMB00 groups showed better results for CS under photopic conditions at low and high spatial frequencies, respectively.

como citar · ABNT NBR 6023

CHAVES, Mario Augusto Pereira Dias et al. Comparative study on optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis ® ZMB00 and AcrySof ® IQ ReSTOR ® Multifocal IOL SN6AD1. Arquivos Brasileiros de Oftalmologia, 2016. DOI: 10.5935/0004-2749.20160050.

Referências

30 obras citadas · 4 no acervo

  1. 1WA Maxwell, RJ Cionni, RP Lehmann e mais 1. Functional outcomes after bilateral implantation of apodized diffractive aspheric acrylic intraocular lenses with a +3.0 or +4.0 diopter addition power: Randomized multicenter clinical study. J Cataracr Refract Surg, 2009quem mais cita →
  2. 2JF Alfonso, L Fernández-Vega, JI Blázquez e mais 1. Visual function comparison of 2 aspheric multifocal intraocular lenses. J Cataract Refract Surg, 2012quem mais cita →
  3. 3NE de Vries e RM Nuijts. Multifocal intraocular lenses in cataract surgery: Literature review of benefits and side effects. J Cataract Refract Surg, 2013quem mais cita →
  4. 4JF Alfonso, L Fernández-Vega, MB Baamonde e mais 1. Prospective visual evaluation of apodized diffractive intraocular lenses. J Cataract Refract Surg, 2007quem mais cita →
  5. 5MA Woodward, JB Randleman e RD Stulting. Dissatisfaction after multifocal intraocular lens implantation. J Cataract Refract Surg, 2009quem mais cita →
  6. 6S Schmickler, CP Bautista, F Goes e mais 2. Clinical evaluation of a multifocal aspheric diffractive intraocular lens. Br J Ophthalmol, 2013quem mais cita →
  7. 7TM Rabsilber, P Rudalevicius, V Jasinskas e mais 2. Influence of +3.00 D and +4.00 D near addition on functional outcomes of a refractive multifocal intraocular lens model. J Cataract Refract Surg, 2013quem mais cita →
  8. 8CM Oliveira, A Ferreira e S Franco. Wavefront analysis and Zernike polynomial decomposition for evaluation of corneal optical quality. J Cataract Refract Surg, 2012quem mais cita →
  9. 9GR Mello, KM Rocha, MR Santhiago e mais 2. Applications of wavefront technology. J Cataract Refract Surg, 2012quem mais cita →
  10. 10WT Hida, CT Nakano, IS Yamane e mais 3. Desempenho visual dos pacientes pseudofácicos com diferentes lentes intraoculares. Rev Bras Oftalmol, 2013no acervo →
  11. 11G Cillino, A Casuccio, M Pasti e mais 3. Working-age cataract patients: visual results, reading performance, and quality of life with three diffractive multifocal intraocular lenses. Ophthalmology, 2014quem mais cita →
  12. 12NE de Vries, CA Webers, R Montés-Micó e mais 2. Visual outcomes after cataract surgery with implantation of a +3.00 D or +4.00 D aspheric diffractive multifocal intraocular lens: comparative study. J Cataract Refract Surg, 2010quem mais cita →
  13. 13WT Hida, AF Motta, N Kara-José Júnior e mais 3. Estudo comparativo do desempenho visual e análise de frente de onda entre as lentes intra-oculares multifocais difrativas Tecnis® ZM900 e AcrySof® ResTor® SN60D3. Arq Bras Oftalmol, 2008no acervo →
  14. 14P Aristodemou, NE Knox Cartwright, JM Sparrow e mais 1. Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry. J Cataract Refract Surg, 2011quem mais cita →
  15. 15LF Jindra e V Zemon. Contrast sensitivity testing: a more complete assessment of vision. J Cataract Refract Surg, 1989quem mais cita →
  16. 16J Richman, GL Spaeth e B Wirostko. Contrast sensitivity basics and a critique of currently available tests. J Cataract Refract Surg, 2013quem mais cita →
  17. 17CP Bautista, DC González e AC Gómez. Evolution of visual performance in 70 eyes implanted with the Tecnis(®) ZMB00 multifocal intraocular lens. Clin Ophthalmol (Auckland, N.Z.), 2012quem mais cita →
  18. 18YT Hong, SW Kim, EK Kim e mais 1. Contrast sensitivity measurement with 2 contrast sensitivity tests in normal eyes and eyes with cataract. J Cataract Refract Surg, 2010quem mais cita →
  19. 19K Pesudovs, CA Hazel, RM Doran e mais 1. The usefulness of Vistech and FACT contrast sensitivity charts for cataract and refractive surgery outcomes research. Br J Ophthalmol, 2004quem mais cita →
  20. 20JF Alfonso, L Fernández-Vega, MB Baamonde e mais 1. Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens. J Cataract Refract Surg, 2007quem mais cita →
1–20 de 30 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações