acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “tonometry”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Dynamic contour tonometry and goldman applanation tonometry in eyes with keratoconus

    Jackson Barreto Jr, Mirko Babic, Roberto Murad Vessani e mais 1Clinics2006

    PURPOSE: The dynamic contour tonometer is a nonapplanation contact tonometer designed to be largely independent of the structural properties of the cornea. Theoretically, it may measure intraocular pressure most accurately in abnormally thinner corneas. This study compares intraocular pressure measurements by dynamic…

  2. Macroscopic morphological aspects, ecometry and rebound tonometry of the eye bulb in sloth (Bradypus variegatus)

    Richelle S. Braz, Marleyne J.A.A.L. Amorim, Fabrício B. Sá e mais 5Pesquisa Veterinária Brasileira2020

    ABSTRACT: The field related to the visual system of wild animals is deeply scarce. Settling anatomical and physiological parameters for these animals is still a descriptive vision for Bradypus variegatus (Schinz, 1825). Thus, our research aimed to determine patterns of normal eye for this species. For this purpose…

  3. Rebound tonometry versus Goldmann tonometry in school children: feasibility and agreement of intraocular pressure measurements

    Bruno Leonardo Barranco Esporcatte, Flávio Siqueira Santos Lopes, Camila Fonseca Netto e mais 4Arquivos Brasileiros de Oftalmologia2015

    ABSTRACT Purpose: High intraocular pressure (IOP) is an important risk factor for a variety of pediatric ophthalmic conditions. The purpose of this study is to evaluate the feasibility, length of examination, and corneal epithelial damage induced by rebound tonometry (RBT) versus Goldmann applanation tonometry (GAT)…

  4. Modified Schirmer tear test and rebound tonometry in blue-fronted Amazon parrot (Amazona aestiva)

    Mário S.A. Falcão, Rafael V. Monteiro, Arianne P. Oriá e mais 1Pesquisa Veterinária Brasileira2017citado por 2 artigos

    ABSTRACT: The aim of this study was to describe the modified Schirmer tear test (mSTT), intraocular pressure (IOP) by rebound tonometry and palpebral fissure length (PFL) in blue-fronted Amazon parrots (Amazona aestiva). Thirty-five healthy adult animals from a conservation breeding center in Brazil were used in this…

  5. Assessment of intraocular pressure in chinchillas of different age groups using rebound tonometry

    Flor Diana Yokoay Claros Chacaltana, João Antonio Tadeu Pigatto e Ione Terezinha DenardinCiência Rural2016citado por 1 artigo

    ABSTRACT: The aim of this research was to measure the intraocular pressure (IOP) of normal chinchilla eyes using the rebound tonometer. A further aim was to assess whether there were differences in the values of intraocular pressure in relation to animals age, gender and time of day. Thirty-six chinchillas were…

  6. Endothelial function assessed by peripheral arterial tonometry is not related with FGF23 serum levels in pre-dialysis CKD patients

    Ana Cerqueira, Janete Quelhas-Santos e Manuel PestanaPortuguese Journal of Nephrology & Hypertension2015

    Cardiovascular (CV) diseases are the leading causes of morbidity and mortality in patients with chronic kidney disease (CKD) that encompass the mildest degrees of renal impairment. High levels of phosphate and fibroblast growth factor 23 (FGF-23) are associated with increased CV events in this population. However…

  7. Effects of age on corneal deformation by non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera

    Bruno Freitas Valbon, Renato Ambrósio-Jr., Bruno Machado Fontes e mais 1Arquivos Brasileiros de Oftalmologia2013citado por 1 artigo

    PURPOSE: To correlate parameters derived from corneal deformation resulting from non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) with age in normal eyes from young patients. METHODS: Observational, retrospective study…

  8. Gas tonometry for evaluation of gastrointestinal mucosal perfusion: experimental models of trauma, shock and complex surgical maneuvers - Part 1

    Luiz Francisco Poli de Figueiredo, Eliezer Silva, Ruy Jorge Cruz Jr e mais 1Acta Cirúrgica Brasileira2002citado por 3 artigos

    Substantial clinical and animal evidences indicate that the mesenteric circulatory bed, particularly the gut mucosa, is highly vulnerable to reductions in oxygen supply and prone to early injury in the course of hemodynamic changes induced by trauma, shock, sepsis and several complex surgical maneuvers. Gut hypoxia or…

  9. Gas tonometry for evaluation of gastrointestinal mucosal perfusion: experimental and clinical sepsis¹. part 2

    Eliezer Silva, Luiz Francisco Poli de Figueiredo, Ruy Jorge Cruz Jr e mais 1Acta Cirúrgica Brasileira2002citado por 2 artigos

    Substantial clinical and animal evidences indicate that the mesenteric circulatory bed, particularly the gut mucosa, is highly vulnerable to reductions in oxygen supply and prone to early injury in the course of hemodynamic changes induced by sepsis and septic shock. Gut hypoxia or ischemia is one possible…

  10. Assessment of splanchnic perfusion with gastric tonometry in the immediate postoperative period of cardiac surgery in children

    Renato Lopes de Souza, Werther Brunow de Carvalho, Miguel Angel Maluf e mais 1Arquivos Brasileiros de Cardiologia2001

    OBJECTIVE - A prospective, nonrandomized clinical study to assess splanchnic perfusion based on intramucosal pH in the postoperative period of cardiac surgery and to check the evolution of patients during hospitalization. METHODS - We studied 10 children, during the immediate postoperative period after elective…

  11. Daily physiological intraocular pressure curve and proposal of a mini-curve correlated with serum cortisol levels in adult Criollo horses

    Fabiano da Silva Flores, Eliesse Pereira Costa, Carolina Cauduro da Rosa e mais 3Ciência Rural2026

    ABSTRACT: Measurement of intraocular pressure (IOP) is essential for detection of ocular diseases and evaluation of treatments. Due to the action of several factors on IOP, performing tonometry throughout the day and night reveals its normal distribution and obtains the daily intraocular pressure curve (DPC). This…

  12. Comparison between objective and subjective postoperative intraocular pressure immediately after cataract surgery

    Julia F. Heringer, Gustavo Rosa Gameiro, Maria Fernanda Abalem e mais 1Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: To compare objective and subjective intraocular pressure measurements immediately after cataract surgery and intraocular pressure measurements between less experienced surgeons (Group 1) and experienced surgeons (Group 2). Methods: Surgeons were asked to estimate the IOP after corneal sealing after…

  13. Influence of intrastromal corneal ring implantation on intraocular pressure measurements using different tonometers in keratoconic eyes

    Christiano Scholte, Júlia Maggi Vieira, Leonardo Torquetti e mais 1Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: This study aimed to evaluate the influence of intrastromal corneal ring segment implants on the intraocular pressure measurements using Goldmann applanation tonometry, rebound tonometry, and noncontact tonometry in keratoconic corneas and analyze the intertonometer agreement. Methods: We enrolled 74…

  14. Relationship between the daily intraocular pressure curve and serum cortisol levels in adult Shih Tzus

    Carolina Cauduro da Rosa, Fabiano da Silva Flores, Fernanda Iensen Ferencena e mais 4Ciência Rural2025citado por 1 artigo

    ABSTRACT: This study evaluated the intraocular pressure (IOP) of Shih Tzu dogs for 24 hours to prepare the daily intraocular pressure curve (DPC) and the mini-curve, in addition to analyzing the circulating cortisol values at different times and verifying the relationship with IOP. IOP was evaluated in 12 adult Shih…

  15. Intraocular pressure changes under an atmospheric pressure spectrum in a multiplace hyperbaric chamber

    Sara Edith Moreno Mazo, Fernando Yaacov Peña e Johanna Victoria Osorio RamírezArquivos Brasileiros de Oftalmologia2024

    ABSTRACT Purpose: To evaluate the influence of atmospheric pressure changes on the behavior of intraocular pressure of healthy military individuals-students and instructors of the National Navy’s Diving & Rescue School at the “ARC BOLÍVAR” naval base-during a simulated immersion in the hyperbaric chamber of the Naval…

  16. Glaucoma drainage devices in children: an updated review

    Alex Teles Vasconcelos, José Aloisio Massote, Cassia Senger e mais 3Arquivos Brasileiros de Oftalmologia2024

    ABSTRACT Implantation of glaucoma drainage devices is a valuable therapeutic option, particularly in children with glaucoma refractory to primary surgical treatment. Glaucoma drainage devices are typically used when conjunctival scarring hampers filtration surgery or prior angle procedures are not effective in…

  17. Effects of childhood obesity on ocular pulse amplitude and intraocular pressure

    Semih Bolu, İlke Direkçi e Abdulvahit AşıkArquivos Brasileiros de Oftalmologia2023

    ABSTRACT Purpose: To assess intraocular pressure and ocular pulse amplitude changes in obese children and adolescents using dynamic contour tonometry. Methods: 137 cases, 64 obese and 73 healthy children, who were both age-matched and gender-matched, comprised the study population in this cross-sectional study…

  18. Evaluation of the impact of subepithelial corneal infiltrates on corneal biomechanics after epidemic keratoconjunctivitis

    Ceyhun Arici, Pinar Sultan e Burak MergenArquivos Brasileiros de Oftalmologia2022

    ABSTRACT Purpose: To examine the effect of subepithelial corneal infiltrates on corneal biomechanical properties after epidemic keratoconjunctivitis compared to that in healthy controls. Methods: The cross-sectional study included consecutive patients with bilateral subepithelial corneal infiltrates after epidemic…

  19. Correction methods for noncontact intraocular pressure measurement in patients with keratoconus and healthy individuals

    Azam Alvani, Hassan Hashemi, Mohammad Pakravan e mais 3Arquivos Brasileiros de Oftalmologia2022

    ABSTRACT Purpose: The objective of this study was to investigate the usefulness of four different algorithms to correct noncontact intraocular pressure measurement errors in keratoconus patients and normal individuals. Methods: Noncorrected intraocular pressure and corrected intraocular pressures were measured in one…

  20. Corneal biomechanics and glaucoma beyond the bidirectional impact of intraocular pressure and corneal deformation response

    Rodrigo Brazuna, Marcella Salomão, Bruno Esporcatte e mais 4Revista Brasileira de Oftalmologia2022citado por 1 artigo

    ABSTRACT The purpose of this study was to highlight the impact of biomechanical corneal response in available in vivo tonometry methods for glaucoma management. Systematic review of non-contact air-puff tonometers that analyzes the corneal deformation response, with special focus on the investigation of the…