acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “structural fire design”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Structural fire safety in existing concrete bridges in Brazil: diagnostic structural design analysis

    Vinicius Ippolito e Carla Neves CostaRevista IBRACON de Estruturas e Materiais2026

    Abstract This study presents a structural fire safety assessment of existing concrete bridges in federal highways in Brazil through a diagnostic analysis based on design standards and structural performance benchmarking under fire situations. Despite lower fire incidence compared to buildings, bridges face significant…

  2. Eurocode structural fire design and its application for composite circular hollow section columns

    José Carlos L. Ribeiro, Ricardo H. Fakury e Estevam B. de Las CasasJournal of the Brazilian Society of Mechanical Sciences and Engineering2008citado por 1 artigo

    The tabular structural fire design method for centrally loaded composite columns consisting of concrete filled steel circular hollow sections proposed in EN 1994-1-2:2005 (Eurocode 4: Design of Composite Steel and Concrete Structures - Structural Fire Design) is described here. A design procedure is then discussed…

  3. Analysis of the assessment methods of reinforced concrete beams in fire conditions proposed by NBR 15200

    F. L. BOLINA, B. BAQUES, B. F. TUTIKIAN e mais 1Revista IBRACON de Estruturas e Materiais2018citado por 1 artigo

    Abstract In Brazil, reinforced concrete structures designed based on NBR 6118 [1] must be assessed in fire conditions through NBR 15200 [2], which proposes multiple test methods. Concerning beams, this standard offers the tabular and simplified methods as possible choices. This study aimed to compare these two methods…

  4. Analysis of RC columns and shear walls in fire

    Fabrício Longhi Bolina, Petrus Gorgônio Bulhões da Nóbrega e Valdir Pignatta e SilvaRevista IBRACON de Estruturas e Materiais2024

    Abstract Recent disasters have shown that the failure of columns or shear walls exposed to fire is the main cause of building collapse. The cross-sectional thermal gradient (TG) of these structures justifies the degree of their heating and also justifies their mechanical damage, but the influence of the number of…