acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “square wave voltammetry”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Electroanalytical determination of the herbicide picloram in natural waters by square wave voltammetry

    Marli R. C. Massaroppi, Sergio A. S. Machado e Luis A. AvacaJournal of the Brazilian Chemical Society2003

    This paper describes the use of square wave voltammetry for the electroanalytical determination of picloram in aqueous media. The reaction was found to occur via an irreversible mechanism involving the transference of four electrons, with the reagent adsorbed in the electrode surface. The practical application was…

  2. Determination of fenitrothion in commercial formulations by square wave voltammetry and UV-Vis spectroscopy

    L. Zelayaran Melgar e S. A. S. MachadoJournal of the Brazilian Chemical Society2005

    Square wave voltammetry at a hanging-drop mercury electrode was used as the analytical technique to determine Fenitrothion content in three different commercial formulations. Initially, Fenitrothion determinations were performed in BR buffer (pH 10.5) prepared with pure water. In such solutions, determination and…

  3. Electroanalytical determination of 4-nitrophenol by square wave voltammetry on diamond electrodes

    Valber de A. Pedrosa, Lúcia Codognoto e Luis Alberto AvacaJournal of the Brazilian Chemical Society2003

    The anodic voltammetric behavior of 4-Nitrophenol on a Boron-doped diamond electrode in aqueous solution has been studied using square wave voltammetry. After optimization of the experimental conditions, that model molecule was analyzed in pure water solutions using a Britton-Robinson buffer with pH 6.0 as the…

  4. A comparative study between two different conventional working electrodes for detection of Δ9-tetrahydrocannabinol using square-wave voltammetry: a new sensitive method for forensic analysis

    Marco A. Balbino, Izabel C. Eleotério, Laura S. de Oliveira e mais 4Journal of the Brazilian Chemical Society2014

    Marijuana is a widely consumed illicit drug. Therefore, drug dealers have sought new ways to mask its forensic (spot test) analysis. In this article we describe a methodology for delta-9-tetrahydrocannabinol (Δ9-THC) detection by square-wave voltammetric (SWV) analysis in organic medium (N,N-dimethylformamide) using…

  5. Speciation of arsenic in paddy field water by square wave cathodic stripping voltammetry using a hanging drop mercury electrode

    ANA PAULA O.L. ANTUNES, MÔNIKA GRAZIELLE HEINEMANN, MAYARA CRISTINA M. LORENZ e mais 2Anais da Academia Brasileira de Ciências2025

    Abstract Arsenic is found widely in nature, with mining and the use of pesticides in agriculture being the leading carriers of this metalloid. Considering the harm caused by As in cultivation media, a simple and sensitive method for arsenic speciation in paddy field water samples was developed by square wave cathodic…

  6. Electrochemical reduction of the mycotoxin citrinin at bare and modified with multi-walled carbon nanotubes glassy carbon electrodes in a non-aqueous reaction medium

    Vanessa G. L. Zachetti, Adrian M. Granero, Sebastian N. Robledo e mais 3Journal of the Brazilian Chemical Society2012

    Electrochemical reduction mechanism of citrinin in acetonitrile plus 0.1 mol L-1 (C4H9)4NClO4 at both bare and modified with multi-walled carbon nanotube glassy carbon (GC) electrodes was investigated by cyclic voltammetry and controlled potential electrolysis. Results allowed to infer a complex electroreduction…

  7. A Study of Stripping Voltammetric Behaviour of Cefadroxil Antibiotic in the Presence of Cu (II) and its Determination in Pharmaceutical Formulation

    Ahmad H. Alghamdi, Ali F. Alghamdi e Mohammed A. AlomarPortugaliae Electrochimica Acta2009

    Square-wave voltammetry was used to explore the adsorption property of cefadroxil complex with copper ions on the hanging mercury drop electrode (HMDE). By employing the adsorptive stripping voltammetric approach, a sensitive electroanalytical method for the quantitative analysis of cefadroxil antibiotic was achieved…

  8. Determination of ranitidine in drugs using a mercury coated platinum ultramicroelectrode and hanging mercury dropping electrode

    Andréa R. Malagutti e Luiz H. MazoJournal of the Brazilian Chemical Society2003

    The voltammetric behavior of ranitidine has been studied in aqueous media with a mercury coated platinum ultramicroelectrode (Hg-UME) and by HMDE. The LSV curves for the electroreduction of ranitidine showed that the compound presents two reduction waves in pH < 4.0 and only one in pH > 4.0, the observed waves being…

  9. Highly selective and sensitive voltammetric sensor for captopril determination based on modified multiwall carbon nanotubes paste electrode

    Ali A Ensafi, B Rezaei, Zohre Mirahmadi-Zare e mais 1Journal of the Brazilian Chemical Society2011

    A new sensitive voltammetric sensor was developed for electrochemical determination of captopril (CAP) at a modified multiwall carbon nanotubes paste electrode with p-aminophenol (p-APMCNTPE). The result showed that p-APMCNTPE has high electrocatalytic activity for captopril oxidation at pH 6.0. Cyclic voltammetry…

  10. Square wave voltammetric determination of Dexamethasone on a multiwalled carbon nanotube modified pencil electrode

    B Rezaei, S. Z. Mirahmadi Zare e Ali A EnsafiJournal of the Brazilian Chemical Society2011

    The electrochemical behavior of dexamethasone, a steroid hormone, was studied on a multiwalled carbon nanotube (MWCNTs) modified pencil electrode (PE) by square wave voltammety and electrochemical impedance spectroscopy (EIS). Dexamethasone showed one oxidation peak potential around +0.80 V on the surface of the…

  11. Developing a continuous flow-square wave voltammetry method for determination of atrazine in soil solutions using the hanging mercury drop electrode

    Luciana B. O. dos Santos, Gilberto Abate e Jorge C. MasiniJournal of the Brazilian Chemical Society2006

    This work describes the development of a Continuous Flow-Square Wave Voltammetry method for determination of atrazine using the hanging mercury drop electrode. The best signal to noise ratio was obtained at the square wave frequency of 350 Hz and flow rate of 0.47 mL min-1. Under these conditions, the analytical curve…

  12. Determination of Coumarin in Mikania glomerata Infusions by Square-Wave Voltammetry Using a Boron-Doped Diamond Electrode

    Denise M. Nóbrega, Anabel S. Lourenço, David Douglas S. Fernandes e mais 4Journal of the Brazilian Chemical Society2023

    Infusions of Mikania glomerata Sprengel (guaco) leaves are used in Brazil for the treatment of respiratory diseases. Coumarin is the chemical marker of guaco for quality control purposes. This work proposes a voltammetric methodology to determine coumarin by using a boron-doped diamond electrode. At pH 10 (0.1 mol L-1…

  13. Square-Wave Voltammetry Determination of Ciprofloxacin in Pharmaceutical Formulations and Milk Using a Reduced Graphene Oxide Sensor

    Lucas V. Faria, Jian F. S. Pereira, Gustavo C. Azevedo e mais 3Journal of the Brazilian Chemical Society2019

    In this paper, a simple, sensitive and precise electroanalytical method was developed using a chemically-reduced graphene-oxide (CRGO)-modified glassy carbon electrode and square wave voltammetry (SWV) for determination of ciprofloxacin in pharmaceutical formulations (tablets) and milk samples. Advantages of this…

  14. Square-wave voltammetric determination of rutin in pharmaceutical formulations using a carbon composite electrode modified with copper (II) phosphate immobilized in polyester resin

    Kellen Heloizy Garcia Freitas, Orlando Fatibello-Filho e Ivanildo Luiz de MattosBrazilian Journal of Pharmaceutical Sciences2012

    A carbon composite electrode modified with copper (II) phosphate immobilized in a polyester resin (Cu3(PO4)2-Poly) for the determination of rutin in pharmaceutical samples by square-wave voltammetry is described herein. The modified electrode allows the determination of rutin at a potential (0.20 V vs. Ag/AgCl (3.0…

  15. Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode

    Anderson M. Santos, Fernando C. Vicentini, Patrícia B. Deroco e mais 2Journal of the Brazilian Chemical Society2015

    Simple, fast, and inexpensive electroanalytical procedures were developed for the determination of codeine (COD) solely and paracetamol (PCT) and COD simultaneously in pharmaceutical formulations and human body fluids. The methods involve the combination of square-wave voltammetry (SWV) with a cathodically pretreated…

  16. Square-wave voltammetric determination of acetylsalicylic acid in pharmaceutical formulations using a boron-doped diamond electrode without the need of previous alkaline hydrolysis step

    Elen R. Sartori, Roberta A. Medeiros, Romeu C. Rocha-Filho e mais 1Journal of the Brazilian Chemical Society2009

    In this paper the determination of acetylsalicylic acid (ASA) in pharmaceutical formulations using square-wave voltammetry (SWV) and a boron-doped diamond electrode (BDD) is described. By this proposed method, ASA is directly determined in a 0.01 mol L-1 H2SO4 solution without the need of a previous time-consuming…

  17. Sequential Injection Analysis with Square Wave Voltammetry (SI-SWV) Detection for Investigation of Adsorption of Picloram on a Clay Soil

    Luciana B. O. dos Santos e Jorge C. MasiniJournal of the Brazilian Chemical Society2015

    This paper describes a sequential injection analysis method, with detection by square wave voltammetry using a hanging mercury drop electrode, to determine the herbicide picloram in soil extracts (0.010 mol L-1 CaCl2). The method was applied for determination of the Freundlich parameters related to adsorption of…

  18. Experimental design employed to square wave voltammetry response optimization for the glyphosate determination

    Reinaldo F. Teófilo, Efraim L. Reis, César Reis e mais 2Journal of the Brazilian Chemical Society2004

    The reduction peak current of the derivative N-nitroso of glyphosate herbicide was optimized by experimental design for their determination. The variables involved in the optimization of the square wave voltammetry (SWV) were: voltage step, amplitude, frequency, concentration of the supporting electrolyte and the area…