  1. Cervical ventral slot in rabbits (Oryctolagus cuniculus). Piezosurgery versus conventional technique

    Marcelo Roscamp, Alessandre Hataka, Frederico Carlini Zambon e mais 3Acta Cirúrgica Brasileira2021

    ABSTRACT Purpose To investigate the applicability of piezosurgery for cervical ventral slot (CVS), comparing it with the conventional technique of using high-speed burs for bone wear. Methods Thirty rabbits (Oryctolagus cuniculus) were divided into two treatment groups (T1 and T2) corresponding to CVS between C3-C4…

  2. Influence of Piezosurgery on Bone Healing around Titanium Implants: A Histological Study in Rats

    Marcelo Sirolli, Carlos Eduardo Secco Mafra, Rodrigo Albuquerque Basílio dos Santos e mais 2Brazilian Dental Journal2016

    Abstract The aim of this study was to evaluate histomorphometrically the influence of two techniques of dental implant site preparation on bone healing around titanium implants. Fifteen male Wistar rats (±300 g) were used in the study. Each tibia was randomly assigned to receive the implant site preparation either…

  3. Piezoelectric-assisted Flapless Technique associated with esthetic rehabilitation: a case report

    Jullyana Mayara Preizner Dezanetti Hermeling, Djulyeny Adolfo Cheniski, Giselle Emilãine da Silva Reis e mais 1RGO - Revista Gaúcha de Odontologia2026

    ABSTRACT The esthetics of the smile depends on the harmony between teeth and periodontal tissues, with clinical crown lengthening being an essential strategy in cases of dental disproportions and excessive gingival display. This case report describes the application of the flapless technique, assisted by piezoelectric…

  4. Application of Piezosurgery in Surgical Extraction of Impacted Mandibular Third Molars Versus Conventional Rotatory Technique: A Randomized Controlled Trial

    Jyotsna Rajan, Abhay Taranath Kamath, Srikanth Gadicherla e mais 2Pesquisa Brasileira em Odontopediatria e Clínica Integrada2019

    Abstract Objective: To compare the effectiveness of conventional rotatory and piezosurgery technique for surgical removal of lower third molars. Material and Methods: Twenty patients with impacted lower third molars (with no acute symptoms) were divided into two groups (G1 and G2) and evaluated clinically and…

  5. Comparison between a piezoelectric device and rotary instruments in implant site preparation: an in vivo morphological, histological analysis using pigs

    Gilson Sakita, Sergio Allegrini Junior, Marcos Barbosa Salles e mais 4RGO - Revista Gaúcha de Odontologia2015

    OBJECTIVE: To carry out a histological comparison, at different postoperative periods, of bone tissue repair after implant site preparations on the tibia of pigs using both a piezoelectric device and rotary instruments. METHODS: Surgical procedures were performed on the tibia of four pigs. Five perforations were made…

  6. Comparative study of two autogenous graft techniques using piezosurgery for sinus lifting

    Geraldo Prestes de Camargo Filho, Luciana Corrêa, Claudio Costa e mais 3Acta Cirúrgica Brasileira2010

    PURPOSE: Maxillary sinus lifting is a technique, in which, a possible complication is sinus membrane perforation. The aim of this study was to compare two techniques using ultrasound surgery to perform autogenous graft for maxillary sinus lifting. METHODS: Ten rabbits were used in the study, one of them did not…

  7. Bone damage induced by different cutting instruments: an in vitro study

    Umberto Romeo, Alessandro Del Vecchio, Gaspare Palata e mais 3Brazilian Dental Journal2009citado por 2 artigos

    The aim of this study was to compare the peripheral bone damage induced by different cutting systems. Four devices were tested: Er:YAG laser (2.94 mm), Piezosurgery, high-speed drill and low-speed drill. Forty-five bone sections, divided into 9 groups according to different parameters, were taken from pig mandibles…