  1. Low Potential and Non-Enzymatic Hydrogen Peroxide Sensor Based on Copper Oxide Nanoparticle on Activated Pencil Graphite Electrode

    Mohammad Ali Kamyabi e Nasim HajariJournal of the Brazilian Chemical Society2017citado por 1 artigo

    An electrochemical sensor for H2O2 determination was prepared by electrodepositing copper oxide nanoparticles on the activated pencil graphite electrodes. At first, a study has been made of the optimum conditions for chemical activation of the pencil graphite electrodes (APGE) and then the activated pencil graphite…

  2. Piroxicam voltammetric determination by ultra low cost pencil graphite electrode

    Isaac Yves Lopes de Macêdo, Morgana Fernandes Alecrim, Jerônimo Raimundo Oliveira Neto e mais 3Brazilian Journal of Pharmaceutical Sciences2020

    Piroxicam (PRX) was determined in pharmaceutical capsules with differential pulse voltammetry (DPV) in a three electrode system consisting of a pencil graphite electrode (PGE) as working electrode, a Pt wire and a reference electrode of Ag/AgCl/KCl 3 M. An irreversible oxidation peak was observed in Epa c.a. 0.6 V…

  3. Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes

    Carolina V. Uliana, Hideko Yamanaka, Gustavo S. Garbellini e mais 1Química Nova2010

    An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear…

  4. Fabrication of Lead Ion Selective Electrodes (Pb-ISE) based on Poly Methyl-Methacrylate-Co-Butyl Acrylate (MB28) Thin Film Photo-polymers and Pencil Graphite Electrodes (PGEs)

    A. Ariri, S. Alva, D. S. Khaerudini e mais 1Portugaliae Electrochimica Acta2022citado por 1 artigo

    Abstract The purpose of this study was to fabricate lead ion selective electrode (Pb-ISE) sensors based on a 2:8 ratio of methyl-methacrylate-co-butyl acrylate thin film copolymers (MB28). These sensors were prepared by using a photo-polymerization technique on a pencil graphite electrode (PGE), with a poly-pyrrole-Cl…

  5. On the Use of a TiO2 Sol-Gel for Horseradish Peroxidase Enzyme Immobilization for Development of an Amperometric Biosensor

    Carolina G. da Rocha, Carolina V Uliana e Hideko YamanakaJournal of the Brazilian Chemical Society2021

    The sol-gel technique has drawn considerable attention in the area of biomolecules immobilization by virtue of its intrinsic properties including chemical inertness, thermal stability, and good biocompatibility. The present work reports the development of a bio-sensing methodology which involves the immobilization of…

  6. Individual and simultaneous square wave voltammetric determination of the anticancer drugs emodin and irinotecan at renewable pencil graphite electrodes

    Yassien M. Temerk e Hossieny S. M. IbrahimJournal of the Brazilian Chemical Society2013

    A rapid sensitive and versatile method for the individual and simultaneous determination of the anticancer drugs emodin (Em) and irinotecan (Irino) in biological fluids based on the square wave voltammetry (SWV) using a renewable pencil graphite electrode (PGE) was investigated. Controlled adsorptive accumulation of…