acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “on-line preconcentration”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Immobilized stearic acid as a new sorbent for on-line preconcentration and determination of lead by flow injection flame atomic absorption spectrometry

    Shayessteh Dadfarnia, Ali Mohammed Haji Shabani e Zahra DehghaniJournal of the Brazilian Chemical Society2006

    The present study examines the possibility of immobilization of stearic acid on microcrystalline naphthalene for preparation of microcolumn and evaluation of its potential for adsorption and preconcentration of trace amounts of metal ions. It was found that this sorbent has high affinity for lead. Consequently, a…

  2. Synthesis and application of a functionalized polystyrene resin for on-line preconcentration and determination of cobalt(II) in water samples by flow injection/FAAS

    Mansour Arab Chamjangali, Laleh Sharif-Razavian, Bahram Bahramian e mais 1Journal of the Brazilian Chemical Society2010

    A simple and sensitive flow injection-flame atomic absorption spectrometric (FI-FAAS) method was developed for on-line preconcentration and determination of trace levels of cobalt(II). A mini-column packed with a chloromethylated polystyrene, functionalized with N,N-bis(naphthylideneimino)diethylenetriamine…

  3. On-line preconcentration system using a microcolumn packed with Alizarin Red S-modified alumina for zinc determination by flame atomic absorption spectrometry

    A.M. Haji Shabani, S. Dadfarnia, T. Moosavinejad e mais 1Química Nova2009

    A simple and sensitive on-line flow injection system for determination of zinc with FAAS has been described. The method is based on the separation and preconcentration of zinc on a microcolumn of immobilized Alizarin Red S on alumina. The adsorbed analyte is then eluted with 250 µL of nitric acid (1 mol L-1) and is…

  4. Simultaneous Determination of Rare Earth Elements by ICP OES After On-Line Enrichment Using Multi-Walled Carbon Nanotubes Coated Cellulose Acetate Membrane

    Ehsan Zolfonoun e Seyed Reza YousefiJournal of the Brazilian Chemical Society2016

    This study investigates application of multi-walled carbon nanotubes coated cellulose acetate membrane for on-line extraction and preconcentration of some rare earth elements (Y, La, Ce, Nd, Sm, Gd and Dy) prior to their determination by inductively coupled plasma optical emission spectrometry. Sample solutions…

  5. On-line preconcentration employing a tannin resin for copper determination in plant material and food stuff by atomic absorption spectrometry

    Carlos E. S. Miranda, Susana Olivares, Boaventura F. Reis e mais 1Journal of the Brazilian Chemical Society2000citado por 1 artigo

    A flow system for copper on-line preconcentration, employing a tannin resin prepared from Eucalyptus Saligna Sm, with determination by flame atomic absorption spectrometry is proposed. The manifold was designed by assembling an automatic injector-commutator and a set of three-way solenoid valves which were controlled…

  6. Determination of thallium traces by ETAAS after on-line matrix separation and preconcentration in a flow injection system

    Taherah Asadoulahi, Shayessteh Dadfarnia e Ali Mohammad Haji ShabaniJournal of the Brazilian Chemical Society2007

    A simple and sensitive flow injection system was developed for separation, preconcentration and determination of thallium. Preconcentration is based on the analyte sorption on a microcolumn of dibenzo-18-crown-6 (DB18C6) immobilized on surfactant coated alumina with subsequent elution using a nitric acid solution (500…

  7. Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line

    María S. Di Nezio, Miriam E. Palomeque e Beatriz S. Fernández BandQuímica Nova2005

    The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg…