acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “nickel-titanium”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Mechanical Performance of Nickel-titanium Archwires

    Daniel Jogaib Fernandes, Carlos Nelson Elias, Rafael Vidal e mais 1Materials Research2015citado por 1 artigo

    The purpose of the present work is to compare the mechanical properties of commercially available NiTi orthodontic archwires lots. Superelastic (SE) and heat-activated (HA) NiTi archwires from two lots of six manufacturers (3M, GAC, Tp, Orthosource, Orthometric and Morelli) were partitioned into eleven groups (n=132)…

  2. Nickel-titanium alloys: a systematic review

    Marcelo do Amaral Ferreira, Marco Antônio Luersen e Paulo César BorgesDental Press Journal of Orthodontics2012

    OBJECTIVE: A systematic review on nickel-titanium wires was performed. The strategy was focused on Entrez-PubMed-OLDMEDLINE, Scopus and BioMed Central from 1963 to 2008. METHODS: Papers in English and French describing the behavior of these wires and laboratorial methods to identify crystalline transformation were…

  3. The effect of brushing motion on the cyclic fatigue of rotary nickel titanium instruments

    Gianluca Gambarini, Eugenio Tucci, Rossella Bedini e mais 5Annali dell'Istituto Superiore di Sanità2010

    The goal of the study is to evaluate if the use of rotary nickel-titanium (RNT) instruments, as Hedstroem files, is safe. Twelve twisted files (TF) RNT instruments size 06-25 were selected and randomly divided in 2 groups of 6 instruments each. Group A (new instruments) were used as control. Group B (test) instruments…

  4. Angular deflection of rotary nickel titanium files: a comparative study

    Gianluca Gambarini, Luca Testarelli, Valerio Milana e mais 5Annali dell'Istituto Superiore di Sanità2009

    A new manufacturing method of twisting nickel titanium wire to produce rotary nickel titanium (RNT) files has recently been developed. The aim of the present study was to evaluate whether the new manufacturing process increased the angular deflection of RNT files, by comparing instruments produced using the new…

  5. Styrene polymerization by nickel and titanium catalysts based on tris(pyrazolyl)borate ligands

    Maria C. A. Kuhn, Jaqueline L. da Silva, Adriana C. A. Casagrande e mais 1Journal of the Brazilian Chemical Society2008

    Styrene polymerization with a series of nickel and titanium complexes based on sterically hindered tris(pyrazolyl)borate ligands, TpMs = HB(3-mesityl-pyrazolyl)3 and TpMs* = HB(3-mesityl-pyrazolyl)2(5-mesityl-pyrazolyl) have been studied in the presence of MAO cocatalyst under various polymerization conditions. All…

  6. Evaluation of two-step transformation in Ni-rich titanium-nickel alloys using thermal and internal friction analyses

    Fillipe Stephany de Souza Virgolino, Tiago Felipe de Abreu Santos, Carlos Augusto Nascimento Oliveira e mais 4Matéria (Rio de Janeiro)2019

    ABSTRACT The use of Ti-Ni memory alloys covers several fields of application such as medicine, dentistry, actuators, sensors among others. Because of the thermomechanical behavior of these materials, they are an object of continuous studies and their properties are related to the occurrence of thermoelastic…

  7. Anti-Corrosion and Mechanical Performance of Graphene Oxide and Reduced Graphene Oxide Multi-Layer Coatings Applied to Nickel-Titanium Via Dip-Coating

    Pablo Forlam Ribeiro Batista, Hana Hitomi Koga, Victor Cardoso Campideli e mais 2Materials Research2025

    This study investigated the mechanical and anti-corrosive properties of two graphene derivatives multi-layer coatings applied to a superelastic NiTi alloy. Several aspects of the coating process and electrochemical characterization remain unclear, including the impact of a multilayer during dip-coating on the final…

  8. Apical displacement produced by rotary nickel-titanium instruments and stainless steel files

    José Roberto Vanni, Diana Santana de Albuquerque, Cristina Reiss e mais 3Journal of Applied Oral Science2004citado por 2 artigos

    The aim of this study was to evaluate the apical displacement produced by different rotary nickel-titanium instruments, testing the hypothesis that rotary systems with nickel-titanium instruments produce lower mean values of apical displacement than stainless steel hand instruments. A total of 100 maxillary permanent…

  9. Surface profile of different heat-treated nickel-titanium files before and after root canal preparation

    Iandara de Lima Scardini, Denise Maria Zezell, Juliana Lisboa Couto Marques e mais 2Brazilian Dental Journal2021

    Abstract The aim of this study was to evaluate surface wear, presence of microcracks and surface irregularities of WaveOne (WO) and WaveOne Gold (WOG) instruments before and after multiple uses. Eight Primary instruments of the WO and WOG systems were evaluated, each one was used to prepare six mesial canals of…

  10. Endodontic Retreatment Using a Single Instrument from four Nickel-Titanium Systems - A Micro-CT Study

    Marco Antonio Diniz Azevedo, Thiago Gomes da Silva, Ângela Fernandes e mais 3Brazilian Dental Journal2020

    Abstract This study evaluated the efficiency of using a single instrument from three different rotary multi-file systems and compared them with that of a reciprocating single-file for endodontic retreatment by means of micro-CT. Sixty extracted canines were prepared using a size F2 ProTaper Universal file and…

  11. Cyclic fatigue resistance of Hyflex EDM NiTi rotary files in different distances of pecking motion

    Verônica Magalhães Lima Nunes, Tânia Nunes Soares, Viviane Rangel do Couto e mais 6Brazilian Journal of Oral Sciences2025

    Aim The purpose of this study was to evaluate the effect of different distances of pecking motion on the cyclic fatigue of Hyflex EDM OneFile (Coltene/Whaledent AG, Altstatten, Switzerland) in simulated curved canal. Methods Sixty Hyflex EDM OneFile (#25/0.08) files were tested at three different pecking depths: G(1)…

  12. Investigation of Wear Behavior in Ni-Ti-SiC Composites Fabricated via Microwave Sintering

    P. Hariprasad, K. Kumaresan, Bader Alqahtani e mais 1Materials Research2024

    The combination of nickel (Ni) and titanium alloy (Ti) with silicon carbide (SiC) reinforcement offers promising avenues for research and applications due to their exceptional resistance to heat, oxidation, and corrosion properties. These studies investigate the influence of silicon carbide (SiC) on Ni-Ti matrix…

  13. Endodontic techniques with Nickel Titanium instruments: analysis of quality and efficiency of instrumentation in primary molars

    Maria Luiza da Matta Felisberto FERNANDES, Caroline Andrade MAIA, Gabriele Andrade MAIA e mais 3RGO - Revista Gaúcha de Odontologia2023

    ABSTRACT Objective: The purpose of the present in vitro study was to evaluate the efficiency of three different instruments in the root canals of artificial primary molars as well as the quality of the fillings. Methods: Sixty artificial primary molars were divided into three groups of 20 teeth. Each group was…

  14. Alignment efficiency and three-dimensional assessment of root resorption after alignment with conventional and copper-nickel-titanium archwires: A randomized controlled trial

    Navleen Kaur BHATIA, Vinay Kumar CHUGH, Sam Prasanth SHANKAR e mais 4Dental Press Journal of Orthodontics2023

    ABSTRACT Objective: To compare alignment efficiency and root resorption between nickel-titanium (NiTi) and copper-nickel-titanium (CuNiTi) archwires after complete alignment in mandibular anterior region. Methods: In this two-arm parallel single-blind randomized controlled trial, forty-four patients with Class I…

  15. Ionic concentration in periradicular medium after dissolution of endodontic file fragments: an in vitro study

    Fabiola ORMIGA, Caroline Chavadian Fonseca AMARAL, Felipe Martins VIEIRA e mais 7Brazilian Oral Research2022

    Abstract The aim of this study was to obtain ionic quantification in periradicular medium after diffusion tests of the solution used inside root canals during the electrochemical dissolution of endodontic file fragments and the NiTi-containing dissolution product via an apical foramen. Thirty single-rooted extracted…

  16. Pulpal blood flow changes and pain scores related to using Superelastic 0.018-inch Nickel Titanium as the first orthodontic alignment archwire: a prospective clinical trial

    Elham S. Abu ALHAIJA, Ahmad Y. SHAHIN, Serene A. BADRAN e mais 2Journal of Applied Oral Science2021

    Abstract Background Optimal orthodontic force results in maximum rate of tooth movement without tissue damage. Even though starting orthodontic treatment with a thicker archwire may shorten treatment duration, the evidence on the effect of using 0.018-inch NiTi as the first alignment archwire on pulpal blood flow…

  17. Torsional Resistance of Two New Heat Treated Nickel Titanium Rotary Instruments: An in Vitro Evaluation

    Gianluca Gambarini, Gabriele Miccoli, Dario Di Nardo e mais 4Pesquisa Brasileira em Odontopediatria e Clínica Integrada2020

    Abstract Objective: To evaluate the difference in torsional resistance, angular deflection and fragment length between two new rotary instruments: AF Blue S4 and S-One. These files share all features except cross-sectional design. Material and Methods: A total of 40 new Nickel-Titanium instruments of 25 mm in length…

  18. Debris extrusion and foraminal deformation produced by reciprocating instruments made of thermally treated NiTi wires

    Myrna Maria Arcanjo Frota, Ricardo Affonso Bernardes, Rodrigo Ricci Vivan e mais 3Journal of Applied Oral Science2018citado por 3 artigos

    Abstract Objective To evaluate the amount of apically extruded debris, percentage of foraminal enlargement and apical foramen (AF) deformation that occurred during root canal preparation with different reciprocation systems: Reciproc, WaveOne (M-Wire), and ProDesign R (Shape Memory Technology Wire) at two different…