acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “monolithic columns”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Physical and electrophoretic characterization of octadecyl methacrylate-based monolithic columns for use in capillary electrochromatography

    Valeska S. Aguiar e Carla B. G. BottoliJournal of the Brazilian Chemical Society2013

    Organic monolithic columns with high efficiency were obtained for use in capillary electrochromatography (CEC) from a mixture of monomers (constant concentrations) with different proportions of porogenic solvents (1,4-butanediol with isoamyl alcohol, amyl alcohol or cyclohexanol in the presence or absence of water)…

  2. Reversed-Phase Liquid Chromatography Methods Based on C18 Polymer Monoliths for the Determination of Urinary Myoglobin

    Renan Vitek, Fernando H. do Nascimento e Jorge C. MasiniJournal of the Brazilian Chemical Society2023

    This study describes reversed-phase liquid chromatography (RPLC) methods to quantify urinary myoglobin using polymer monolithic columns produced by copolymerization of stearyl methacrylate (SMA) and ethylene glycol dimethacrylate (EDMA). The columns were prepared in the coffins of 1.5 mm internal diameter (i.d.)…

  3. Synthesis of Hybrid Monolithic Columns Using a Click Chemistry Reaction for Application in Capillary Liquid Chromatography

    Marcella E. P. Schmidt e Carla B. G. BottoliJournal of the Brazilian Chemical Society2019

    Hybrid monolithic columns present characteristics of both silica and organic monoliths, such as good mechanical properties, wide pH tolerance, high permeability and stability and little swelling or shrinkage. A common way to prepare this type of material is by using alkoxysilanes and organic monomers via the sol-gel…

  4. Coupled monolithic columns as an alternative for the use of viscous ethanol–water mobile phases on chromatographic fingerprinting complex samples

    Cristiano Soleo Funari, Alberto José Cavalheiro e Renato Lajarim CarneiroRevista Brasileira de Farmacognosia2018

    ABSTRACT Concepts of sustainability have received attention from people involved in investigation of nature-derived matrices. The effects of concomitant pollutant activities are cumulative and harmful to the environment from which these matrices are obtained. High performance liquid chromatography analyses generate…

  5. Monolithic equivalent stiffness of precast columns with grouted splice sleeve connections

    Marcelo de Araujo Ferreira, Luís Augusto Bachega e Bruna CatoiaRevista IBRACON de Estruturas e Materiais2021

    abstract The aim of this paper is the validation of monolithic equivalent stiffness applied to precast columns with grouted splice sleeve connections, wherein spliced precast elements have been compared with continuous monolithic elements. The experimental investigation has been carried out with bending tests for two…

  6. Evaluation of Monolithic and Core-Shell Columns for Separation of Triazine Herbicides by Reversed Phase High Performance Liquid Chromatography

    Ricardo P. Urio e Jorge C. MasiniJournal of the Brazilian Chemical Society2015

    Monolithic and core-shell columns were comparatively evaluated for separation of deisopropylatrazine (DIA), deethylatrazine (DEA), hydroxyatrazine (HAT), simazine (SIM) and atrazine (ATR) under similar conditions of elution, flow rate and sample volume. Although both columns provided separation of the analytes with…