acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “monolithic column”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Fast HPLC analysis of omeprazole, 5-hydroxyomeprazole and omeprazole sulfone in liquid culture medium using a monolithic column for application in biotransformation studies with fungi

    Keyller B. Borges, Rosa Durán-Patrón, Antonio José M. Sánchez e mais 3Journal of the Brazilian Chemical Society2011

    A fast liquid chromatography method was developed and validated for the simultaneous determination of omeprazole (OMZ), 5-hydroxyomeprazole (5-HOMZ) and omeprazole sulphone (OMZ SUL) in liquid culture medium for application in biotransformation studies employing phytopathogenic and endophytic fungi. The separation was…

  2. Physical and electrophoretic characterization of octadecyl methacrylate-based monolithic columns for use in capillary electrochromatography

    Valeska S. Aguiar e Carla B. G. BottoliJournal of the Brazilian Chemical Society2013

    Organic monolithic columns with high efficiency were obtained for use in capillary electrochromatography (CEC) from a mixture of monomers (constant concentrations) with different proportions of porogenic solvents (1,4-butanediol with isoamyl alcohol, amyl alcohol or cyclohexanol in the presence or absence of water)…

  3. Optimized Separation Method for Estriol, 17-β-Estradiol and Progesterone by Capillary Electrochromatography with Monolithic Column and its Application to a Transdermal Emulsion

    Rafael Marques, Fernando A. S. Vaz, Hudson C. Polonini e mais 1Journal of the Brazilian Chemical Society2015

    A monolithic stationary phase based on 3-(methacryloxypropyl)trimethoxysilane monomer, prepared within a fused silica capillary externally coated with a UV-transparent fluoropolymer was employed for separation of estriol, 17-b-estradiol and progesterone by capillary electrochromatography in a standard mixture. A 23…

  4. Reversed-Phase Liquid Chromatography Methods Based on C18 Polymer Monoliths for the Determination of Urinary Myoglobin

    Renan Vitek, Fernando H. do Nascimento e Jorge C. MasiniJournal of the Brazilian Chemical Society2023

    This study describes reversed-phase liquid chromatography (RPLC) methods to quantify urinary myoglobin using polymer monolithic columns produced by copolymerization of stearyl methacrylate (SMA) and ethylene glycol dimethacrylate (EDMA). The columns were prepared in the coffins of 1.5 mm internal diameter (i.d.)…

  5. Synthesis of Hybrid Monolithic Columns Using a Click Chemistry Reaction for Application in Capillary Liquid Chromatography

    Marcella E. P. Schmidt e Carla B. G. BottoliJournal of the Brazilian Chemical Society2019

    Hybrid monolithic columns present characteristics of both silica and organic monoliths, such as good mechanical properties, wide pH tolerance, high permeability and stability and little swelling or shrinkage. A common way to prepare this type of material is by using alkoxysilanes and organic monomers via the sol-gel…

  6. Coupled monolithic columns as an alternative for the use of viscous ethanol–water mobile phases on chromatographic fingerprinting complex samples

    Cristiano Soleo Funari, Alberto José Cavalheiro e Renato Lajarim CarneiroRevista Brasileira de Farmacognosia2018

    ABSTRACT Concepts of sustainability have received attention from people involved in investigation of nature-derived matrices. The effects of concomitant pollutant activities are cumulative and harmful to the environment from which these matrices are obtained. High performance liquid chromatography analyses generate…

  7. ON-LINE SOLID PHASE EXTRACTION COUPLED WITH LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY FOR THE DETERMINATION OF CODEINE IN HUMAN PLASMA

    Alessandro de C. Cruz, Eunice M. Suenaga, Eduardo Abib e mais 1Química Nova2017

    A specific LC-MS/MS method was developed and validated for automated determination of codeine in human plasma, using on-line solid phase extraction (SPE) system coupled with positive ion electrospray ionization tandem mass spectrometry. The method allowed plasma direct injection onto cartridge without sample…

  8. Multi-component quantitation of loratadine, pseudoephedrine and paracetamol in plasma and pharmaceutical formulations with liquid chromatography-tandem mass spectrometry utilizing a monolithic column

    Kamran Abro, Najma Memon, M. I. Bhanger e mais 2Química Nova2012

    The purpose of this study was to develop a rapid, simple and sensitive quantitation method for pseudoephedrine (PSE), paracetamol (PAR) and loratadine (LOR) in plasma and pharmaceuticals using liquid chromatography-tandem mass spectrometry with a monolithic column. Separation was achieved using a gradient composition…

  9. A sensitive and robust lc-ms/ms method with monolithic column and electrospray ionization for the quantitation of efavirenz in human plasma: application to a bioequivalence study

    Danilo Cesar Galindo Bedor, Jose Homero de Souza Filho, Virna Ligiane Souza Ramos e mais 3Química Nova2011

    An LC-MS/MS method has been developed for the determination of efavirenz (EFZ) in human plasma using hydrochlorothiazide as internal standard (I.S.). An ESI negative mode with multiple reaction-monitoring was used monitoring the transitions m/z 313.88→69.24 (EFZ) and 296.02→204.76 (I.S.). Samples were extracted using…

  10. Determination of picloram in waters by sequential injection chromatography with UV detection

    Luciana B. O. dos Santos, Carlos M. C. Infante e Jorge C. MasiniJournal of the Brazilian Chemical Society2010citado por 4 artigos

    This paper describes a sequential injection chromatography procedure for determination of picloram in waters exploring the low backpressure of a 2.5 cm long monolithic C18 column. Separation of the analyte from the matrix was achieved in less than 60 s using a mobile phase composed by 20:80 (v v-1) acetonitrile:5.0…

  11. Nonlinear analysis of monolithic beam-column connections for reinforced concrete frames

    Gerson Alva e Alexandre TsutakeRevista IBRACON de Estruturas e Materiais2020citado por 1 artigo

    abstract: This paper deals with nonlinear analysis of deformability of monolithic beam-column connections for bending moments in framed reinforced concrete structures. Due to the simplicity, the connections deformability is considered by using an analytical model of moment-rotation curve. Material nonlinearity of the…

  12. Monolithic equivalent stiffness of precast columns with grouted splice sleeve connections

    Marcelo de Araujo Ferreira, Luís Augusto Bachega e Bruna CatoiaRevista IBRACON de Estruturas e Materiais2021

    abstract The aim of this paper is the validation of monolithic equivalent stiffness applied to precast columns with grouted splice sleeve connections, wherein spliced precast elements have been compared with continuous monolithic elements. The experimental investigation has been carried out with bending tests for two…

  13. Evaluation of Monolithic and Core-Shell Columns for Separation of Triazine Herbicides by Reversed Phase High Performance Liquid Chromatography

    Ricardo P. Urio e Jorge C. MasiniJournal of the Brazilian Chemical Society2015

    Monolithic and core-shell columns were comparatively evaluated for separation of deisopropylatrazine (DIA), deethylatrazine (DEA), hydroxyatrazine (HAT), simazine (SIM) and atrazine (ATR) under similar conditions of elution, flow rate and sample volume. Although both columns provided separation of the analytes with…

  14. Influence of the stiffness of beam-column connections on the structural analysis of reinforced concrete buildings

    J. B. SANTOS, T. J. DA SILVA e G. M. S. ALVARevista IBRACON de Estruturas e Materiais2018citado por 2 artigos

    Abstract Conventional structural analysis of buildings in reinforced concrete is performed considering beam-column connections as rigid. However, experimental results prove the existence of relative rotations in beam-column connections of reinforced concrete structures, showing the partial transfer of bending moment…