acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “microtomography”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Pathological Studies in Uteruses by X-ray Microtomography

    L. M. Gonçalves, O. M. O. Araujo, A. S. Machado e mais 2Brazilian Journal of Radiation Sciences2026

    Abstract X-ray computed microtomography (microCT) is an advanced technique for evaluating materials that uses the principle of X-ray attenuation to form high-resolution two- and three-dimensional images. This technique allows detailed visualization of the microstructures of biological samples through the digital…

  2. Porosity Characterization of Iron Ore Pellets by X-Ray Microtomography

    Karen Soares Augusto e Sidnei PaciornikMaterials Research2018citado por 1 artigo

    This work proposes a three-dimensional methodology to characterize porosity in iron ore pellets by X-ray Microtomography (microCT). An image analysis routine was developed to discriminate and quantify open/closed porosity. The results were compared to the traditional techniques of mercury intrusion porosimetry (MIP)…

  3. Analyzing the compressive behavior of porous Ti6Al4V by X-ray microtomography

    Iván Farias, Luís Olmos, Omar Jimenez e mais 4Materials Research2017

    Samples with 40% vol. of pores and a pore size distribution between 100 and 500 µm were produced by powder metallurgy from Ti6Al4V alloy powders. Sintering was performed at 1300 °C during one hour in an inert Argon atmosphere in a vertical dilatometer. The compressive strength and the porosity of these samples was…

  4. Characterization of test specimens produced in reduced size for X-ray microtomography (µ-CT) tests

    E. E. BERNARDES, A. G. DE MAGALHÃES, W. L. VASCONCELOS e mais 3Revista IBRACON de Estruturas e Materiais2017

    Abstract The need to use reduced sample sizes, in order to attain improved spatial resolution in (µ-CT) tests applied in Portland cement composites, makes researchers perform the fractionation of materials to obtain samples with dimensions compatible with the capacity of the scanning equipment, which might cause…

  5. SEM and 3D microtomography application to investigate the distribution of fibers in advanced cementitious composites

    F. PACHECO, R. CHRIST, A. M. GIL e mais 1Revista IBRACON de Estruturas e Materiais2016citado por 2 artigos

    Abstract The incorporation of fibers on cement composites reduces its fragility, turning it a ductile material. The amount of fibers and its distribution presents a large influence on the composite performance, especially by the fact that it is self-consolidating, which facilitates the fiber distribution. 3D…

  6. Microstructure of Holstein and Gir breed adult bovine hooves: histomorphometry, three-dimensional microtomography and microhardness test evaluation

    R.E. Rabelo, V.A.S. Vulcani, F.J.F. Sant'Ana e mais 3Arquivo Brasileiro de Medicina Veterinária e Zootecnia2015citado por 2 artigos

    This study aimed to characterize and compare the aspects involved in the microstructural formation of the Holstein and Gir breed hoof wall by histomorphometry, three-dimensional microtomography and microhardness test techniques. Seventy-two (18H/18G thoracic and 18H/18G pelvic) Holstein (H) and Gir (G) breed hooves…

  7. The effect of simvastatin on relapse of tooth movement and bone mineral density in rats measured by a new method using microtomography

    Giovanni Modesto Vieira, Sacha Braun Chaves, Vânia Maria Moraes Ferreira e mais 2Acta Cirúrgica Brasileira2015

    PURPOSE: To evaluate the effect of simvastatin on relapse of tooth movement in rats using microtomography (micro CT), as well as the correlation of bone density with the orthodontic relapse.METHODS: Twenty-five adult male Wistar rats, divided into two groups, had stainless steel springs installed on left maxillary…

  8. 3D investigation of steel fiber distribution in reinforced concrete by X-ray microtomography

    A. C. MACHADO, M. A. SILVA, R. D. T. FILHO e mais 3Revista IBRACON de Estruturas e Materiais2015citado por 1 artigo

    ABSTRACTThe effects of the inclusion of steel fibers in concrete have been widely studied in order to investigate possible changes in mechanical properties, such as the increase in tensile strength, ductility, stiffness, toughness (energy absorption capacity), and durability. An immediate consequence of this addition…

  9. Two and three-dimensional morphometric analysis of trabecular bone using X-ray microtomography (µCT)

    Alessandro Márcio Hakme da Silva, José Marcos Alves, Orivaldo Lopes da Silva e mais 1Revista Brasileira de Engenharia Biomédica2014

    INTRODUCTION: Trabecular bones have a porous microstructure and can be modeled as linear elastic solids, heterogeneous and anisotropic. In the literature, few investigations have compared the two- dimensional (2D) and three-dimensional (3D) morphometric analyses of cancellous bone. METHODS: In this investigation…

  10. Evaluation of the effect of varying the workability in concrete pore structure by using X-ray microtomography

    E. E. Bernardes, A. G. de Magalhães, W. L. Vasconcelos e mais 1Revista IBRACON de Estruturas e Materiais2013

    The useful life of concrete is associated with the penetrative ability of aggressive agents on their structures. Structural parameters such as porosity, pore distribution and connectivity have great influence on the properties of mass transport in porous solids. In the present study, the effect of varying the…

  11. Role of X-ray microtomography in tissue engineering

    Andrea Barbetta, Rossella Bedini, Raffaella Pecci e mais 1Annali dell'Istituto Superiore di Sanità2012citado por 1 artigo

    The structure and architecture of scaffolds are crucial factors in scaffolds-based tissue engineering since they affect the functionality of the tissue engineering construct and the eventual application in health care. Therefore, effective scaffold assessment techniques are required right at the initial stages of…

  12. Microtomography evaluation of dental tissue wear surface induced by in vitro simulated chewing cycles on human and composite teeth

    Rossella Bedini, Raffaella Pecci, Gianluca Notarangelo e mais 3Annali dell'Istituto Superiore di Sanità2012

    In this study a 3D microtomography display of tooth surfaces after in vitro dental wear tests has been obtained. Natural teeth have been compared with prosthetic teeth, manufactured by three different polyceramic composite materials. The prosthetic dental element samples, similar to molars, have been placed in…

  13. The application of X-ray microtomography for the assessement of root resorption caused by the orthodontic treatment of premolars

    Monika Sawicka, Rossella Bedini, Raffaella Pecci e mais 2Annali dell'Istituto Superiore di Sanità2012

    The purpose of this study was to demonstrate potential application of micro-computed tomography in the morphometric analysis of the root resorption in extracted human first premolars subjected to the orthodontic force. In one patient treated in the orthodontic clinic two mandibular first premolars subjected to…

  14. Determination of the Representative Elementary Volume for the study of sandstones and siltstones by X-Ray microtomography

    Jaquiel Salvi Fernandes, Carlos Roberto Appoloni e Celso Peres FernandesMaterials Research2012

    X-Ray computerized microtomography (µ-CT) besides providing two-dimensional images (2-D) of the transversal sections of the sample, the biggest attraction of the methodology is the rendering of three-dimensional images (3-D), enabling a more real analysis of the porous structure of the rock. However, the…

  15. Ceramic foams porous microstructure characterization by X-ray microtomography

    Carlos Roberto Appoloni, Celso Peres Fernandes, Murilo Daniel de Mello Innocentini e mais 1Materials Research2004citado por 2 artigos

    Knowledge of the porous structure of amorphous materials is of fundamental importance in calculating geometrical parameters such as total porosity, pore size distribution and physical parameters relating to fluid flow inside void space. The present work deals with the measurement of the microstructural parameters of…

  16. Three-Dimensional Evaluation of Accessory Canals in Primary Maxillary Molars Using Micro-CT

    Alice Moura Martins, Juliana de Medeiros Matos, Carolina Oliveira de Lima e mais 3Brazilian Dental Journal2026

    Abstract The objective of the present study was to characterize the internal anatomy of primary maxillary molars by evaluating the presence and distribution of accessory canals using micro-computed tomography (micro-CT). Seventeen primary maxillary molars from donors aged 2 to 8 years were scanned using micro-CT and…

  17. Controlling Internal Root Anatomy Bias in Ex vivo Shaping Evaluation: Matched Pairs vs. Multivariate Analysis

    Hugo Victor Dantas, Fabio Luiz Cunha D’Assunção e Frederico Barbosa De SousaBrazilian Dental Journal2026

    Abstract This laboratory study evaluated the non-inferiority of multivariate analysis (MA) compared with sample selection using pairs of teeth matched by similar root canal internal anatomy (MP) to control the confounding effect of root canal system anatomy on the shaping ability of endodontic instruments. Following…

  18. Ultrasonic irrigation in curved root canals: effect of insert type on debris and dentin removal

    Hermano Camelo Paiva, Eduardo Akisue, Laila Gonzales Freire e mais 4Brazilian Dental Journal2026

    Abstract This study aimed to evaluate the influence of the ultrasonic insert type (Nitisonic [nickel-titanium], Irrisonic [stainless steel], and UltraX Blue [hybrid alloy]) on three primary parameters: the volume and depth of uncontrolled dentin removal, removal of accumulated hard tissue debris (AHTD), and canal…

  19. Impact of acidic pH and sealer thickness on the physical behavior of endodontic sealers: a micro-CT study

    Karina Ines Medina Carita TAVARES, Airton Oliveira SANTOS-JUNIOR, Jáder Camilo PINTO e mais 3Brazilian Oral Research2026

    Abstract The aim of this study was to evaluate the effect of immersion in an acidic (butyric acid – BA; pH 4.1) or neutral (phosphate-buffered saline - PBS; pH 7.0) environment on the physical behavior of Bio-C Sealer (BCS) or AH Plus Jet (AHPJ) after filling oval root canals with different thicknesses of sealer…