acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “ion selective electrode”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Influence of the medium (strongly acid or basic) over the electrochemical properties of the nitrate selective electrode

    Rubén DEL TÓRO DÉNIZ, E. M. RAJMANKO, Ana María PEÓN ESPINOSA e mais 1Eclética Química1997

    A nitrate selective electrode was prepared for use in an aggresive medium (high acidic or basic concentration). It is demonstrated that the depending E graph with respect to pNO3- has not a Nernstian response in concentration acidic range upper 0.1 mol/L H2SO4. The observed behaviour is supposed to be due to the…

  2. Use of a Ca-selective electrode in the determination of total Ca in the production of crude sugar. Preliminary studies

    Jorge GONZÁLEZ GARCÍA, V.V. EGONOV, Rubén DEL TÓRO DÉNIZ e mais 3Eclética Química1997

    The determination of the total calcium in juice, syrups, and other products of the sugar industry is investigated. Total calcium and free calcium is determinated by AAS and employing Ca-selective electrode respectively. A coefficient is obtained for the relation of total calcium with respect to free calcium. The…

  3. Simultaneous determination of chloride and potassium in carbohydrate electrolyte beverages using an array of ion-selective electrodes controlled by a microcomputer

    Julio Cesar B. Fernandes, Graciliano de Oliveira Neto, Jarbas José R. Rohwedder e mais 1Journal of the Brazilian Chemical Society2000

    This work describes the building of a potentiometric system composed of an array of ion-selective electrodes and controlled by microcomputer. The system employed an acquisition card model ACL-8111 from ADLink Technology for the selection control of the ion-selective electrodes through an analogic switch (ADG201) with…

  4. Ion-Selective Electrode for the Determination of Iron(III) in Vitamin Formulations

    Marcos Fernando de S. Teixeira, Clezio Aniceto e Orlando Fatibello-FilhoJournal of the Brazilian Chemical Society1998

    A coated graphite-epoxy ion-selective electrode for iron(III), based on the ion-pair formed between [Fe(citrate)2]3- and the tricaprylylmethylammonium cation (Aliquat 336) in a poly(vinylchloride) (PVC) matrix has been constructed. A thin membrane film of this ion-pair, dibutylphthalate (DBPh) in PVC was deposited…

  5. New Acrylate Co-Polymer Membrane Synthetized by Photo-Polymer Technique for Lead (II) Ion-Selective Electrode

    Sagir Alva, Rika Sri Utami, Melny Andrian e mais 7Portugaliae Electrochimica Acta2024

    Abstract A novel p(THFA-co-HEMA) membrane based on acrylate CP was herein successfully synthesized through PP technique, and applied as a membrane for Pb ion-selective electrode (Pb-ISE). Optimal composition of THFA was HEMA 9:1 (TH91), with a Tg of -6.5oC. The structure of p(THFA-co-HEMA) was characterized using…

  6. Fabrication of a new samarium(III) ion-selective electrode based on 3-{[2-oxo-1(2h)-acenaphthylenyliden]amino}-2-thioxo -1,3-thiazolidin-4-one

    Hassan Ali Zamani, Mohammad Reza Ganjali e Mehdi AdibJournal of the Brazilian Chemical Society2007

    This paper introduces the development of an original PVC membrane electrode, based on 3-{[2-oxo-1(2H)-acenaphthylenyliden]amino}-2-thioxo-1,3-thiazolidin-4-one (ATTO) which has revealed to be a suitable carrier for Sm3+ ions. The resulting data illustrated that the electrode shows a Nernstian slope of 19.3 &plusmn…

  7. Fluoride determination in carbon nanotubes by ion selective electrode

    Fabiane G. Antes, Juliana S. F. Pereira, Laurien C. Spadoa e mais 3Journal of the Brazilian Chemical Society2012

    Fluoride determination by ion selective electrode (ISE) in carbon nanotubes (CNTs) is proposed after pyrohydrolysis decomposition. Up to 1 g of CNTs could be decomposed improving the limit of detection (1.5 μg g-1), precision (RSD < 5%) and accuracy (agreement higher than 95% with values of certified reference…

  8. Determination of acetylsalicylic acid in tablets with salicylate ion selective electrode in a Batch Injection Analysis system

    Julio Cesar B. Fernandes, Carlos Alexandre B. Garcia, Luciane A. Grandin e mais 2Journal of the Brazilian Chemical Society1998

    The feasibility of the use of a Batch Injection Analysis (BIA) system for potentiometric determination of acetylsalicylic acid in tablets, with a membrane ion selective electrode, was investigated. There is no significant difference between the results obtained by the proposed method and those obtained by the Standard…

  9. Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore

    Masoomeh Esmaelpourfarkhani, Gholam H. Rounaghi e Mohammad H. Arbab-ZavarJournal of the Brazilian Chemical Society2015

    This article describes the fabrication of a novel and selective polyvinylchloride (PVC) membrane potentiometric sensor for Al3+ cation based on 12-crown-4 (12C4) as an ionophore. The electrode was prepared by coating the surface of a graphite rod by a membrane containing PVC as a plastic matrix, dibutylphthalate (DBP)…

  10. Iodide-selective membrane electrode based on salophen complex of cobalt (III)

    Hamid R. Zare, Farkhondeh Memarzadeh, Alireza Gorji e mais 1Journal of the Brazilian Chemical Society2005

    A highly selective PVC membrane electrode based on a cobalt-salophen complex was prepared. The sensor displays an anti-Hofmeister selectivity sequence with a preference for iodide ion over many common anions. The electrode has a linear dynamic range between 5.0×10-7 to 1.0×10-1 mol L-1, with a Nernstian slope of -58.9…

  11. Highly selective and sensitive membrane salicylate electrode based on complex of (1,8-diamino-3,6-dioxaoctane) nickel(II)

    M. Mazloum-Ardakani, P. Pourhakkak, M. Salavati-Niasari e mais 2Journal of the Brazilian Chemical Society2011

    The potentiometric response of salicylate electrode based on complex of (1,8-diamino-3,6-dioxaoctane) nickel(II) was studied. The complex of 1,8-diamino-3,6-dioxaoctane nickel(II) [Ni(DADOO)] was used as carrier into plasticized polyvinyl chloride (PVC) membrane. The influence of several variables was investigated in…

  12. Fluoride concentration in mouth rinses marketed in Chile and Brazil, and a discussion regarding their legislations

    Astrid Carolina VALDIVIA-TAPIA, Juliana Nunes BOTELHO, Rodrigo Andrés GIACAMAN e mais 2Brazilian Oral Research2021

    Abstract For fluoride to be effective in controlling caries, it should be bioavailable in commercial products, so that it can be released into the mouth in the products it contains. We chemically determined the available fluoride and pH in nine mouth rinses marketed in Chile, and eleven, in Brazil, and then discussed…

  13. On-the-go tropical soil sensing for pH determination using ion-selective electrodes

    Fernanda Cristina de Souza Silva e José Paulo MolinPesquisa Agropecuária Brasileira2018citado por 1 artigo

    Abstract: The objective of this work was to assess the performance of an antimony ion-selective electrode (ISE) sensor system, using manual and automatic operating modes, for measuring the potential of hydrogen (pH), in real time, in Oxisols with different characteristics. Samples were manually collected and sent to a…

  14. Fluoride concentrations in salt marketed in Managua, Nicaragua

    Karla Irina Walsh e Jaime Aparecido CuryBrazilian Oral Research2018citado por 1 artigo

    Abstract Nicaraguan legislation has established that fluoride concentrations in salt should be 200–225 mg/kg, but no report describes fluoride concentrations in salt marketed in this country. We evaluated the fluoride concentrations in 33 packages of salt of 11 brands (n = 3 each) purchased in Managua, Nicaragua…

  15. A Contribution to the estimation of binary halide and pseudo-halide equilibrium constants using a linear extrapolation methodology

    Astréa F. de S. Silva, Manuel M. Ortega, Cristo B. Melios e mais 4Journal of the Brazilian Chemical Society2010

    The molar single ion activity coefficient (yF) of fluoride ions was determined at 25 °C and ionic strengths between 0.100 and 3.00 mol L-1 NaClO4 using an ion-selective electrode. The activity coefficient dependency on ionic strength was determined to be ΦF = log yF = 0.2315I - 0.041I². The function ΦF(I), combined…

  16. Modern directions for potentiometric sensors

    Eric Bakker e Karin Chumbimuni-TorresJournal of the Brazilian Chemical Society2008

    This paper gives an overview of the newest developments of polymeric membrane ion-selective electrodes. A short essence of the underlying theory is given, emphasizing how the electromotive force may be used to assess binding constants of the ionophore, and how the selectivity and detection limit are related to the…

  17. Construction of a novel potentiometric terbium(III) membrane sensor and its application for the determination of terbium ion in binary mixture and fluoride ion in a mouth wash preparation

    Hassan Ali Zamani, Ghadir Rajabzadeh e Mohammad Reza GanjaliJournal of the Brazilian Chemical Society2006

    A new PVC membrane potentiometric sensor that is highly selective to Tb(III) ions was prepared by using 4-amino-3-{2-[4-amino-6-methyl-5-oxo-4,5-dihydro-1,2,4-triazin-3(2H)-yliden] hydrazono}-6-methyl-3,4-dihydro-1,2,4-triazin-5(2H)-one (ATO) as a suitable carrier. The sensor works satisfactorily in the concentration…

  18. Fabrication of Lead Ion Selective Electrodes (Pb-ISE) based on Poly Methyl-Methacrylate-Co-Butyl Acrylate (MB28) Thin Film Photo-polymers and Pencil Graphite Electrodes (PGEs)

    A. Ariri, S. Alva, D. S. Khaerudini e mais 1Portugaliae Electrochimica Acta2022citado por 1 artigo

    Abstract The purpose of this study was to fabricate lead ion selective electrode (Pb-ISE) sensors based on a 2:8 ratio of methyl-methacrylate-co-butyl acrylate thin film copolymers (MB28). These sensors were prepared by using a photo-polymerization technique on a pencil graphite electrode (PGE), with a poly-pyrrole-Cl…

  19. A novel Ho(III) sensor based on N,N'-bis(2- pyridinecarboxamide)-1,2-benzene as a neutral ion carrier

    Mohammad Reza Ganjali, Solmaz Rasoolipour, Morteza Rezapour e mais 3Journal of the Brazilian Chemical Society2006

    N,N'-bis(2- pyridinecarboxamide)-1,2-benzene (H2BPB) was found to have a selective and sensitive behavior towards Ho(III) ion, in comparison to a large number of lanthanide, inner transition and representative metal ions and was hence applied as a neutral ionophore, for preparing an Ho(III) membrane sensor, with high…