acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “internal fixators”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Internal fixators: a safe option for managing distal femur fractures?

    Bruno Bellaguarda Batista, Rodrigo Salim, Cleber Antonio Jansen Paccola e mais 1Acta Ortopédica Brasileira2014

    OBJECTIVE: Evaluate safety and reliability of internal fixator for the treatment of intra-articular and periarticular distal femur fractures. METHODS: Retrospective data evaluation of 28 patients with 29 fractures fixed with internal fixator was performed. There was a predominance of male patients (53.5%), with 52% of…

  2. Open reduction and internal fixation of posterior pilon fractures with buttress plate

    Da-wei Chen, Bing Li, Ashwin Aubeeluck e mais 3Acta Ortopédica Brasileira2014

    Objective: Posterior pilon fractures are rare injuries and have not yet gained well recognition. The purpose of this study was to present the treatment outcome for patients with posterior pilon fractures treated with buttress plate. Method: In this retrospective study we identified patients with posterior pilon…

  3. POSTOPERATIVE STABILITY AFTER VOLAR LOCKING PLATE IN DISTAL RADIUS FRACTURES

    Luiz Henrique Santos Cambrussi, Douglas Barbosa Lima, Marcos Afonso Grando e mais 2Acta Ortopédica Brasileira2026

    ABSTRACT Objective: To evaluate the correction and maintenance of radiographic parameters—volar tilt (VT), radial inclination (RI), and radial height (RH)—from the preoperative period to outpatient discharge in distal radius fractures treated with a volar locking plate (VLP), stratified by AO/OTA, Fernandez, and IDEAL…

  4. SCREW VS. SUTURE FIXATION FOR TIBIAL EMINENCE FRACTURES: A META-ANALYSIS

    Paulo Eduardo Dias Lavigne, Marcus Vinicius Ribeiro Filho, Victor Mendes Ribeiro e mais 3Acta Ortopédica Brasileira2026

    ABSTRACT Objectives: To compare functional and surgical outcomes between screw and suture fixation in pediatric tibial spine fractures. Materials and Methods: This systematic review followed PRISMA guidelines and was registered in PROSPERO (CRD420251022233). Cohort studies comparing arthroscopic screw versus suture…

  5. Analysis of Intraoperative Exposure to X-rays and Surgical Time in Different Techniques for Fixation of Transtrochanteric Fractures of the Femur

    Lucas Carneiro Curty Bastos Guerra e Leo Ribeiro ChiarelliRevista Brasileira de Ortopedia2021

    Abstract Objective The present study aimed to evaluate and compare the total surgical procedure time and intraoperative X-ray exposure during different techniques for fixation of transtrochanteric fractures of the femur in elderly patients, using extramedullary and intramedullary methods based on cephalic traction…

  6. Axis screws: results and complications of a large case series

    Cleiton Formentin, Erion Junior de Andrade, Fernando Luis Maeda e mais 3Revista da Associação Médica Brasileira2019

    SUMMARY OBJECTIVE: To present the surgical results of patients who underwent axis screw instrumentation, discussing surgical nuances and complications of the techniques used. METHODS: Retrospective case-series evaluation of patients who underwent spinal surgery with axis instrumentation using screws. RESULTS…

  7. Comparison of Bite Force with Locking Plates versus Non-Locking Plates in the Treatment of Mandibular Fractures: A Meta-Analysis

    José Cristiano Ramos Glória, Ighor Andrade Fernandes, Esmeralda Maria da Silveira e mais 4International Archives of Otorhinolaryngology2018

    Abstract Introduction Mandibular fractures represent a high percentage of all facial fractures, and the bite force is a fundamental parameter to measure the actual mandibular function and, subsequently, the masticatory efficiency and quality of life. Objectives The purpose of the present systematic review was to…

  8. THE USE OF NITINOL RODS IN SURGICAL TREATMENT OF DEGENERATIVE SCOLIOSIS. 2.5-YEAR FOLLOW-UP

    Natalia Sergeyevna Morozova, Dmitriy Aleksandrovich Kolbovsky, Arkadiy Ivanovich Kazmin e mais 1Coluna/Columna2016

    ABSTRACT Objectives: To compare the outcomes of surgical treatment with lumbar fixation using nitinol rods without fusion and with standard lumbar fixation with titanium rods and interbody fusion. Methods: Treatment results of 70 patients with degenerative lumbar scoliosis aged 40 to 82 were analyzed. In all cases…

  9. Postoperative infection in patients undergoing inspection of orthopedic damage due to external fixation

    Noel Oizerovici Foni, Felipe Augusto Ribeiro Batista, Luís Henrique Camargo Rossato e mais 3Revista Brasileira de Ortopedia2015citado por 1 artigo

    ABSTRACT OBJECTIVE: To conduct a retrospective analysis on cases undergoing inspection of orthopedic damage, at an orthopedic emergency service in a teaching hospital, with the aim of evaluating patients with postoperative infection after conversion to internal osteosynthesis. METHODS: This was a retrospective…

  10. Analysis on the mechanical resistance of fixation of femoral neck fractures in synthetic bone, using the dynamic hip system and an anti-rotation screw,

    Anderson Freitas, Gustavo Melo Torres, André Cezar de Andrade de Mello e Souza e mais 3Revista Brasileira de Ortopedia2014

    Objective:To statistically analyze the results obtained from biomechanical tests on fixation of femoral neck fractures of Pauwels III type, in synthetic bone, using the dynamic hip system with an anti-rotation screw, versus a control group.Methods:Ten synthetic bones from a Brazilian manufacturer (model C1010) were…

  11. Dynamic compared to rigid fixation in lumbar spine: a systematic review

    Ricardo Vieira Botelho, Rafael Bastianello Junior, Luciana DiniGianini de Albuquerque e mais 1Revista da Associação Médica Brasileira2014

    Objective: The objective of this review is to reveal the quality of published data and the effect size of DPFs compared to rigid fixation in lumbar spine. Summary of background data: since 2002, several dynamic pedicle fixation (DPF) systems have been developed with the aim to stabilize the spine without the…

  12. Mechanical analysis of femoral neck fracture fixation with dynamic condylar screw in synthetic bone

    Anderson Freitas, Rafael Almeida Maciel, Renato De Almeida Lima e mais 2Acta Ortopédica Brasileira2014

    Objective: To analyze statistically results in biomechanical testing of fixation of femoral neck Pauwels type III fractures, on synthetic bone, with dynamic condylar screw (DCS) and control group.Methods: Ten synthetic bones of a national brand were used. Test Group: fixation was performed after osteotomy at 70o tilt…

  13. Outcome comparison of Lisfranc injuries treated through dorsal plate fixation versus screw fixation

    Sun-jun Hu, Shi-min Chang, Xiao-hua Li e mais 1Acta Ortopédica Brasileira2014

    OBJECTIVE: The objective of this prospective study was to test whether the treatment of Lisfranc injuries with open reduction and dorsal plate fixation would have the same or better functional outcomes as treatment with standard trans-articular screw fixation. METHODS: Sixty patients with primarily isolated Lisfranc…

  14. In vivo studies on flexion and extension of the lumbar spine after stabilisation with a non-fusion pedicle screw system

    Jörg Rainer Klauß, MJ Richter, Hendrik Bergert e mais 2Coluna/Columna2012

    OBJECTIVE: The aim was to determine in vivo whether pre-operative mobility of the lumbar spine (overall and segmental) is retained after surgical intervention. METHODS: Functional imaging of the lumbar spine was performed in flexion and extension, using a lateral projection under standardised conditions. This allowed…

  15. INTERFERENCE OF EXTERNAL DAMAGE CONTROL FIXATION IN DEFINITIVE OSTEOSYNTHESIS

    JULIO CESAR DO AMARAL MUSSATTO, FERNANDO BALSIMELLI, GUILHERME DO AMARAL MUSSATTO e mais 3Acta Ortopédica Brasileira2022

    ABSTRACT Introduction: Indications for provisional external fixation prior to the definitive treatment of fractures are associated with the control of local and systemic damage and the impossibility of definitive osteosynthesis in the emergency. Objective: To identify complications associated with external fixation…

  16. CT-guided percutaneous sacroiliac stabilization in unstable pelvic fractures: a safe and accurate technique

    Govind Gandhi, Mayank Vijayvargiya, Vivek Shetty e mais 3Revista Brasileira de Ortopedia2018

    ABSTRACT Objective The use of open reduction and internal fixation (ORIF) for unstable pelvic injuries is associated with extensive blood loss, iatrogenic neurovascular injury, and infection. Moreover, the placement of sacroiliac (SI) screws is a blinded procedure, guided primarily by palpation and two-dimensional…

  17. Supra-acetabular fixation and sacroiliac screws for treating unstable pelvic ring injuries: preliminary results from 20 patients

    Rodrigo Pereira Guimarães, Arthur de Góes Ribeiro, Oliver Ulson e mais 3Revista Brasileira de Ortopedia2016

    OBJECTIVE: To analyze the treatment results from 20 patients who underwent an alternative osteosynthesis method as definitive treatment for pelvic ring fractures. METHODS: A retrospective analysis was conducted on a series of 20 patients with pelvic ring fractures (Tile type C) and a high risk of postoperative…