acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “graphite electrode”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Electrochemical feasibility study of methyl parathion determination on graphite-modified basal plane pyrolytic graphite electrode

    Leonardo Luiz Okumura, Adelir Aparecida Saczk, Marcelo Firmino de Oliveira e mais 4Journal of the Brazilian Chemical Society2011

    A low-cost electrochemical method was developed for the determination of trace-level of methyl parathion (MP) based on the properties of graphite-modified basal plane pyrolytic graphite electrode (graphite-bppg). A combination of graphite-bppg with square-wave voltammetric (SWV) analysis resulted in an original…

  2. Electrochemical Oxidation of Landfill Leachate: Investigation of Operational Parameters and Kinetics Using Graphite-PVC Composite Electrode as Anode

    Zainab H. Mussa, Mohamed R. Othman e Md P. AbdullahJournal of the Brazilian Chemical Society2015

    The preparation of a new carbon composite electrode constructed from graphite-polyvinyl chloride (graphite-PVC) compressed mixtures was used for the first time to treat landfill leachate in Malaysia under electrochemical oxidation. The electrochemical oxidation of landfill leachate was studied on graphite-PVC and Pt…

  3. Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrode

    Carolina M. F. Calixto, Priscila Cervini e Éder T. G. CavalheiroJournal of the Brazilian Chemical Society2012

    A bare graphite-polyurethane composite was evaluated in the tetracycline (TC) determination in natural water samples. Using differential pulse voltammetry (DPV), a linear response was observed in the range of 4.00-40.0 µmol L-1 with limit of detection of 2.80 µmol L-1, without the need of surface renewing between…

  4. Evaluation of a Fe2O3-based graphite-epoxy tubular electrode as pH sensor in flow injection potentiometry

    Marcos F. de S. Teixeira, Luiz A. Ramos, Neila M. Cassiano e mais 2Journal of the Brazilian Chemical Society2000

    A systematic evaluation of a Fe2O3 graphite-epoxy tubular electrode was investigated through pH measurements in a single-channel flow injection system. The tubular electrode was obtained by deposition of a mixture of iron(III) oxide, graphite powder and epoxy resin into a hole previously made in the injection channel…

  5. Determination of paracetamol at a graphite-polyurethane composite electrode as an amperometric flow detector

    Priscila Cervini e Éder Tadeu Gomes CavalheiroJournal of the Brazilian Chemical Society2008

    A bare graphite-polyurethane composite was evaluated as an amperometric flow injection detector in the determination of paracetamol (APAP) in pharmaceutical formulations. A linear analytical curve was observed in the 5.00 x 10-5 to 5.00 x 10-3 mol L-1 range with a minimum detectable net concentration of 18.9 µmol L-1…

  6. Evaluation of a Graphite-Polyurethane Composite Electrode Modified with Copper Nanoparticles as an Amperometric Flow Detector in a Wall-Jet System for the Determination of Cysteine

    Isabela A. Mattioli, Letícia F. L. Schildt, Priscila Cervini e mais 2Journal of the Brazilian Chemical Society2020

    A graphite-polyurethane composite electrode (GPUE) was modified by electrodeposition of copper nanoparticles (CuNP) followed by electrochemical treatment in NaOH (GPUE-CuNP), in order to prepare an amperometric sensor for the determination of cysteine (Cys). Cyclic votammograms of Cys solutions at GPUE-CuNP allowed…

  7. The use of a graphite-silicone rubber composite electrode in the determination of rutin in pharmaceutical formulation

    Sidney X. dos Santos, Luiz H. Mazo e Éder T. G. CavalheiroJournal of the Brazilian Chemical Society2008citado por 1 artigo

    The possibility of using a graphite silicone-rubber composite electrode (GSR) in a differential pulse voltammetric(DPV) procedure for rutin (vitamin P) determination is described. Cyclic voltammograms of rutin presented a reversible pair of oxidation/reduction peaks respectively at 0.411 and 0.390 V (vs. SCE) at the…

  8. Simultaneous voltammetric determination of acetaminophen and caffeine at a graphite and polyurethane screen-printed composite electrode

    Thalita R. Saciloto, Priscila Cervini e Éder T. G. CavalheiroJournal of the Brazilian Chemical Society2013

    A selective electrochemical method was developed for the individual or simultaneous determination of acetaminophen and caffeine in phosphate buffer pH 6.0 on graphite and polyurethane screen-printed composite electrode (EIGPU) using Differential Pulse Voltammetry (DPV). The oxidation peaks of acetaminophen and the…

  9. Low Potential and Non-Enzymatic Hydrogen Peroxide Sensor Based on Copper Oxide Nanoparticle on Activated Pencil Graphite Electrode

    Mohammad Ali Kamyabi e Nasim HajariJournal of the Brazilian Chemical Society2017citado por 1 artigo

    An electrochemical sensor for H2O2 determination was prepared by electrodepositing copper oxide nanoparticles on the activated pencil graphite electrodes. At first, a study has been made of the optimum conditions for chemical activation of the pencil graphite electrodes (APGE) and then the activated pencil graphite…

  10. Electrocatalytic and voltammetric determination of sulfhydryl compounds through iron nitroprusside modified graphite paste electrode

    Devaney R. do Carmo, Ricardo M. da Silva e Nelson R. StradiottoJournal of the Brazilian Chemical Society2003citado por 1 artigo

    Iron nitroprusside Fe(II)NP was incorporated into a carbon paste electrode and the electrochemical studies were performed with cyclic voltammetry. The cyclic voltammogram of Fe(II)NP exhibits two redox couple with formal potential (E0')1 = 0.24 e (E0')2 = 0.85 V vs SCE attributed to Fe(II)/Fe(II) and Fe(II)(CN)5NO /…

  11. Piroxicam voltammetric determination by ultra low cost pencil graphite electrode

    Isaac Yves Lopes de Macêdo, Morgana Fernandes Alecrim, Jerônimo Raimundo Oliveira Neto e mais 3Brazilian Journal of Pharmaceutical Sciences2020

    Piroxicam (PRX) was determined in pharmaceutical capsules with differential pulse voltammetry (DPV) in a three electrode system consisting of a pencil graphite electrode (PGE) as working electrode, a Pt wire and a reference electrode of Ag/AgCl/KCl 3 M. An irreversible oxidation peak was observed in Epa c.a. 0.6 V…

  12. The behavior of graphite and copper electrodes on the finish die-sinking electrical discharge machining (EDM) of AISI P20 tool steel

    Fred L. Amorim e Walter L. WeingaertnerJournal of the Brazilian Society of Mechanical Sciences and Engineering2007citado por 1 artigo

    The machining parameter settings installed at CNC EDM machines are developed under optimum process conditions. Standard workpiece and electrode materials are used traditionally by machine manufacturers to establish the EDM parameter settings. However, this is not the usual situation of the tooling industry, where many…

  13. Using of a graphite-polyurethane composite electrode modified with a Schiff base as a bio-inspired sensor in the dopamine determination

    Sidney X. dos Santos e Éder T. G. CavalheiroJournal of the Brazilian Chemical Society2014

    A solid composite electrode based on graphite and polyurethane resin modified with a copper(II) complex of the symmetrical tetradentate Schiff's base type, N, N'-ethylenebis(salicylideneiminato) copper(II) ([Cu(II)Salen]), was evaluated as a bio-inspired sensor using dopamine (DA) as a model analyte. The voltammetric…

  14. Graphite-Polyurethane Composite Electrode Modified with Molecularly Imprinted Polymer for Determination of Diclofenac

    Abigail V Pereira, Priscila Cervini, Victor A. G Rivera e mais 1Journal of the Brazilian Chemical Society2022

    A molecularly imprinted polymer (MIP) was prepared using the anti-inflammatory diclofenac (DCF) as a template. A non-imprinted polymer (NIP) was also prepared as a control. These MIP and NIP were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and Brunauer-Emmett-Teller…

  15. STUDY OF THE ELECTRICAL CONDUCTIVITY OF GRAPHITE FELT EMPLOYED AS A POROUS ELECTRODE

    E.O. Vilar, N.L. de Freitas, F.R. de Lirio e mais 1Brazilian Journal of Chemical Engineering1998

    The objective of the present work is to study the variation of the electrode distribution potential under electrical conductivity variation of graphite felt RVG 4000 ( Le Carbone Lorraine) when submitted to a mechanical compression. Experimental and theoretical studies show that this electrical conductivity variation…

  16. N-propylpyridinium chloride silsesquioxane polymer film on graphite: electrochemical study of a hexacyanoferrate (II) ion immobilized electrode for oxidation of ascorbic acid

    Rení V. S. Alfaya, Yoshitaka Gushikem e Antonio A. S. AlfayaJournal of the Brazilian Chemical Society2000

    A well polished graphite surface was coated with a thin film of N-propylpyridinium chloride silsesquioxane polymer. On to the strongly graphite-adhered polymer film the electroactive species [Fe(CN)6]4- was adsorbed by means of an ion exchange reaction. The resulting electrode (graph/SiPy+)4[Fe(CN)6 ]4- (graph =…

  17. Cr (VI) electromechimal reduction using RVG 4OOO graphite felt as the electrode

    E.O. Vilar, E.B. Cavalcanti, H.R. Carvalho e mais 1Brazilian Journal of Chemical Engineering2003

    Even in at very low concentrations, heavy metals in industrial waste constitute environmental and health risks. The U.S. Department of Health and Human Services has recognized as chromium compounds and defined carcinogens the level acceptable in drinking water as being only 0.05 ppm. The objective of this work was the…

  18. Potentiostatic Co-deposition of Nickel and Graphite Using a Composite Counter Electrode

    B. Aremo, M.O. Adeoye e I. B. ObiohPortugaliae Electrochimica Acta2019

    Nickel and graphite were potentiostatically co-deposited using a nickel-graphite composite counter electrode (HCE) with tunable-friability. Graphite electrodes were produced at densities of 0.920, 1.026 and 1.188 g/cm³, and their suitability for constitution into HCE was assessed. The surface area of the nickel…

  19. Fabrication of Lead Ion Selective Electrodes (Pb-ISE) based on Poly Methyl-Methacrylate-Co-Butyl Acrylate (MB28) Thin Film Photo-polymers and Pencil Graphite Electrodes (PGEs)

    A. Ariri, S. Alva, D. S. Khaerudini e mais 1Portugaliae Electrochimica Acta2022citado por 1 artigo

    Abstract The purpose of this study was to fabricate lead ion selective electrode (Pb-ISE) sensors based on a 2:8 ratio of methyl-methacrylate-co-butyl acrylate thin film copolymers (MB28). These sensors were prepared by using a photo-polymerization technique on a pencil graphite electrode (PGE), with a poly-pyrrole-Cl…