acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “flow injection system”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Determination of sulfamethoxazole in pharmaceutical formulations by flow injection system/HPLC with potentiometric detection using polypyrrole electrode

    Sabriye P. Ozkorucuklu, Yucel Sahin e Guleren AlsancakJournal of the Brazilian Chemical Society2011citado por 1 artigo

    In this work, it was used a polypyrrole (PPy) electrode as a potentiometric electrochemical detector in a flow injection system in order to determine sulfamethoxazole in pharmaceutical formulations. The PPy electrode was prepared by cyclic voltammetry in acetonitrile solution. A linear relationship was observed over…

  2. Determination of thallium traces by ETAAS after on-line matrix separation and preconcentration in a flow injection system

    Taherah Asadoulahi, Shayessteh Dadfarnia e Ali Mohammad Haji ShabaniJournal of the Brazilian Chemical Society2007

    A simple and sensitive flow injection system was developed for separation, preconcentration and determination of thallium. Preconcentration is based on the analyte sorption on a microcolumn of dibenzo-18-crown-6 (DB18C6) immobilized on surfactant coated alumina with subsequent elution using a nitric acid solution (500…

  3. Preparation and Characterization of a PVC/TTF-TCNQ Composite Electrode: Applications in a Flow Injection System

    Manuel Cano, Beatriz Palenzuela e Rafael Rodríguez-AmaroPortugaliae Electrochimica Acta2007

    It was prepared a new polyvinyl chloride (PVC)/tetrathiafulvalene-tetracyanoquinodimethane (TTF-TCNQ) composite electrode which showed good physical and electrochemical characteristics. Different PVC/TTF-TCNQ-graphite proportions were tested and the relation 1/10 (p/p) PVC/TTF-TCNQ provided the best results in terms…

  4. Spectrophotometric flow injection system for determination of Zn2+ in ophthalmic formulations using Alizarin red S

    Orlando Fatibello-Filho e Heberth Juliano VieiraEclética Química2009

    A spectrophotometric flow injection method for the determination of Zn(II) in ophthalmic formulations was developed. In this work, Zn(II) ion was complexed with Alizarin red S in borate buffer solution (pH 9.0) and the chromophore produced was monitored at 520 nm. The analytical curve was linear in the Zn(II)…

  5. Flow injection green method for the quantitative analysis of ketoconazole in pharmaceutical preparations

    Felipe Scatolin, Matthieu Tubino e Marta Maria Duarte Carvalho VilaQuímica Nova2010

    A flow injection method for the quantitative analysis of ketoconazole in tablets, based on the reaction with iron (III) ions, is presented. Ketoconazole forms a red complex with iron ions in an acid medium, with maximum absorbance at 495 nm. The detection limit was estimated to be 1×10--4 mol L-1; the quantitation…

  6. Determination of boron in natural water and products derived from grape using an automated flow injection analysis system with piezoelectric detection

    Dosil P. de Jesus, Renata M. Saito e Claudimir L. do LagoJournal of the Brazilian Chemical Society2004

    An automated flow injection analysis system with piezoelectric detection is proposed as a sensitive and selective method for boron. The detector is an electrode-separated piezoelectric quartz crystal coated with N-methyl-D-glucamine-modified poly(epichlorohydrin). The film ability to retain boron allows the adjustment…

  7. Oxalate determination in urine using an immobilized enzyme on sorghum vulgare seeds in a flow injection conductimetric system

    Graciliano de Oliveira Neto, Matthieu Tubino, Oswaldo Espirito Santo Godinho e mais 2Journal of the Brazilian Chemical Society1997

    A flow-injection (FI) method was developed for the determination of oxalate in urine. It was based on the use of oxalate oxidase (E.C. 1.2.3.4) immobilized on ground seeds of the BR-303 Sorghum vulgare variety. A reactor was filled with this activated material, and the samples (200 µL) containing oxalate were passed…

  8. Evaluation of a simple hyphenated system for flow injection solid-phase pre-concentration and capillary electrophoresis

    Nilson A. Assunção, Carlos E. S. Miranda, Fernando M. Lanças e mais 2Journal of the Brazilian Chemical Society2008

    In this work, the development and evaluation of a hyphenated flow injection-capillary electrophoresis system with on-line pre-concentration is described. Preliminary tests were performed to investigate the influence of flow rates over the analytical signals. Results revealed losses in terms of sensitivity of the…

  9. Simple flow injection amperometric system for simultaneous determination of dipyrone and paracetamol in pharmaceutical formulations

    Wallans T. P. dos Santos, Denise T. Gimenes, Edimar G. N. de Almeida e mais 3Journal of the Brazilian Chemical Society2009

    In this work a simple flow injection methodology with pulsed amperometric detection for simultaneous determination of dipyrone (DI) and paracetamol (PCT) in pharmaceutical formulations is described. The compounds are detected by applying four sequential potential pulses as function of the time. Dipyrone is directly…

  10. A Flow System for Spectrophotometric Multidetermination in Water Exploiting Reagent Injection

    Patrícia B. Martelli, Fábio R. P. Rocha, Rejane C. P. Gorga e mais 1Journal of the Brazilian Chemical Society2002

    A flow system for spectrophotometric multidetermination in waters is proposed. Reagent aliquots (25-75 μL) were inserted into the sample stream, allowing up to 4.5-fold increase in sensitivity and an average 12-fold reduction in reagent consumption. The system allows the determination of phosphate (0.25 – 5.0 mg L-1)…

  11. Development of a flow injection system with two analytical paths for ammonium determination in soil extracts by conductometry

    Boaventura F. Reis, Jonas A. Vieira, Francisco José Krug e mais 1Journal of the Brazilian Chemical Society1997citado por 2 artigos

    A flow injection system with two analytical paths for ammonium determination in soil extracts by conductometry is described. The ammonia generated on line in an alkaline medium is permeated through a hydrophobic membrane (TPFE), collected by a deionized water stream and directed toward the conductivity flow cell. The…

  12. Monitoring of diclofenac with biomimetic sensor in batch and FIA systems

    Ademar Wong, Luiz D. Marestoni e Maria D. P. T. SotomayorJournal of the Brazilian Chemical Society2014

    The present work aims the development of a biomimetic sensor for the detection of sodium diclofenac from a glassy carbon electrode modified with copper(II) 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine complex and functionalized multi-walled carbon nanotubes (MWCNT-COOH). The proposed sensor was evaluated in…

  13. Performance of Avocado Seed Activated Carbon as Adsorbent for Highly Sensitive Determination of Cd Using a Flow Injection System Online Coupled to TS-FF-AAS

    Marianne V. F. Kudo, Leandro L. G. de Oliveira, Fabio A. C. Suquila e mais 5Journal of the Brazilian Chemical Society2020

    A flow-injection preconcentration system using detection by the thermospray flame furnace atomic absorption spectrometry (FIA-TS-FF-AAS) is proposed. Cd2+ are adsorbed on avocado seed activated carbon (ASAC) packed into a cylindrical mini-column and eluted using HCl solutions for the detection system. A 25–1…

  14. Spectrophotometric determination of phosphorus in iron alloys employing a flow injection system

    Ana P. G. Gervasio, Carlos E. S. Miranda, Gilmara C. Luca e mais 3Journal of the Brazilian Chemical Society2001

    A flow-injection procedure for spectrophotometric determination of phosphorus in electrolytic iron and iron alloys is proposed. The method is based on the ammonium molybdate reaction followed by stannous chloride reduction in acidic medium. In order to circumvent the severe interference caused by the major…

  15. Flow Injection Analysis System for Screening Organophosphorus Pesticides by their Inhibitory Effect on the Enzyme Acethylcholinesterase

    Marcos P. Silva, Matthieu Tubino, Tereza C. R. Elsholz e mais 3Journal of the Brazilian Chemical Society2015

    A flow-injection spectrophotometric procedure was developed for screening organophosphorus pesticides. The method is based on the inhibition of acetylcholinesterase immobilized on controlled porous glass beads with acetylcholine chloride as the substrate. Methyl parathion, chlorpyrifos, malathion and dichlorvos have…

  16. Short-term toxicity test: monitoring Klebsiella oxytoca bacterium respiration using a flow injection analysis/conductometric system

    José R. Guimarães, Carolina R. T. Farah e Pedro S. FadiniJournal of the Brazilian Chemical Society2012

    In this study, the Klebsiella oxytoca bacterium was used as a test organism in short-term toxicity evaluations, and Escherichia coli was used as reference. The inhibition of bacterial growth was quantified by flow injection analysis (FIA) via conductometric measurements of the CO2 produced during respiration. The…

  17. A pH optode based on thymol blue: application to determination of CO2 using flow injection analysis system

    M.D.P.T. Sotomayor, I.M. Raimundo Jr, J.J. R. Rohwedder e mais 1Eclética Química2010

    An optode based on thymol blue (TB), an acid-based indicator, has been constructed and evaluated as a detector in FIA system for CO2 determination. The dye was chemically immobilised on the surface of a bifurcated glass optical fibre bundle, using silanisation in organic media. In FIA system, hydrogen carbonate or…

  18. Flow-Injection spectrophotometric system for captopril determination in pharmaceuticals

    Willian T. Suarez, Alexandro A. Madi, Luiz C. S. de Figueiredo-Filho e mais 1Journal of the Brazilian Chemical Society2007citado por 1 artigo

    A simple, accurate and precise flow-injection spectrophotometric procedure is reported for the determination of captopril in pharmaceutical formulations. In this procedure, captopril was oxidized by iron(III) and the iron(II) produced was spectrophotometrically monitored as iron(II)-1,10-phenantroline complex at 540…

  19. Sequential injection analysis determination of sulphate in wastewaters by ultraviolet-spectrophotometry

    Rui A. S. Lapa, José L. F. C. Lima e Ivone V. O. S. PintoJournal of the Brazilian Chemical Society2000

    A sequential injection analysis system based on the formation of the cation FeSO4+ and the spectrophotometric measuring of the absorbance at 355 nm has been developed for the determination of sulphate in wastewaters. The main interferents were also evaluated. The proposed system is fully automatized and is able to…

  20. Sensitive determination of perphenazine in pharmaceuticals and human serum by flow injection chemiluminescence method using [Ru(phen)3]2+-ce(IV) system and a chemometrical optimization approach

    B. Rezaei e A. MokhtariJournal of the Brazilian Chemical Society2011

    This paper describes a simple, rapid and sensitive chemiluminescence (CL) method for the determination of perphenazine by flow injection (FI) system. All variables that can affect the CL response were optimized by employing central composite design (CCD) for the experimental design and response surface methodology…