acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “flow analysis”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Automatic photometric titration procedure based on multicommutation and flow-batch approaches employing a photometer based on twin LEDs

    Milton B. da Silva, Carla C. Crispino e Boaventura F. ReisJournal of the Brazilian Chemical Society2010

    In this work, a reliable and inexpensive photometer based on twin LEDs assembled as a radiation source and as a photodetector is described. The setup including the photometer and flow system module was designed to implement an automated titration procedure employing the multicommuted flow injection analysis (MCFIA)…

  2. A LED based photometer for solid phase photometry: zinc determination in pharmaceutical preparation employing a multicommuted flow analysis approach

    Tuanne R. Dias e Boaventura F. ReisJournal of the Brazilian Chemical Society2012

    In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C18)…

  3. Flow-injection analysis with multiple-pulse amperometry for simultaneous determination of paracetamol and naproxen using a homemade flow cell for screen-printed electrodes

    Jessica S. Stefano, Rodrigo H. O. Montes, Eduardo M. Richter e mais 1Journal of the Brazilian Chemical Society2014

    This work reports the simultaneous determination of paracetamol and naproxen using multiple-pulse amperometric detection on a multi-walled carbon nanotube modified screen-printed electrode (MWCNT-SPE) adapted in a homemade flow-injection analysis (FIA) cell. A sequence of two potential pulses (+0.30 and +0.70 V for 70…

  4. Flow Analysis: Looking Back and Forward

    Fábio R. P. RochaJournal of the Brazilian Chemical Society2018

    Flow analysis changed significantly the way of performing chemical analysis by (i) mechanization of analytical procedures in a continuous flowing stream with minimal sample intercontamination; (ii) analytical measurements without attaining chemical equilibria, thus increasing the applicability of kinetic methods and…

  5. Exploiting gas diffusion for non-invasive sampling in flow analysis: determination of ethanol in alcoholic beverages

    Simone Vicente, Elias A.G. Zagatto, Paula C.A.G. Pinto e mais 3Anais da Academia Brasileira de Ciências2006

    A tubular gas diffusion PTFE membrane is exploited for non-invasive sampling in flow analysis, aiming to develop an improved spectrophotometric determination of ethanol in alcoholic beverages. The probe is immersed into the sample, allowing ethanol to diffuse through the membrane. It is collected into the acceptor…

  6. Chemically Modified Carbon Paste Electrodes for Ascorbic Acid Determination in Soft Drinks by Flow Injection Amperometric Analysis

    M. Goreti F. Sales, M.S.A. Castanheira, Rosa M.S. Ferreira e mais 2Portugaliae Electrochimica Acta2008

    Simple, rapid and precise amperometric methods for quantification of ascorbic acid (AA) are presented. Glassy carbon (GC), carbon paste (CP) and modified carbon paste (MCP) electrodes are used for this purpose. MCP electrodes are of CP with 10 % vanadate (V). All electrodes are inserted in a wall-jet device with an…

  7. A Flow System for Spectrophotometric Multidetermination in Water Exploiting Reagent Injection

    Patrícia B. Martelli, Fábio R. P. Rocha, Rejane C. P. Gorga e mais 1Journal of the Brazilian Chemical Society2002

    A flow system for spectrophotometric multidetermination in waters is proposed. Reagent aliquots (25-75 μL) were inserted into the sample stream, allowing up to 4.5-fold increase in sensitivity and an average 12-fold reduction in reagent consumption. The system allows the determination of phosphate (0.25 – 5.0 mg L-1)…

  8. Flow injection analysis of vancomycin

    M. M. D. C. Vila, A. A. Salomão e M. TubinoEclética Química2008

    A flow injection method for the quantitative analysis of vancomycin hydrochloride, C66H75Cl2N9O24.HCl (HVCM), based on the reaction with copper (II) ions, is presented. HVCM forms a lilac-blue complex with copper ions at pH≅4.5 in aqueous solutions, with maximum absorption at 555 nm. The detection limit was estimated…

  9. Solid-phase extractions in flow analysis

    FÁBIO R.P. ROCHA, ALEX D. BATISTA, WANESSA R. MELCHERT e mais 1Anais da Academia Brasileira de Ciências2018

    ABSTRACT Coupling solid-phase extraction (SPE) to flow systems has promoted a synergistic development. Whereas SPE mechanization leads to improved precision and higher sample throughput, as well as diminishes systematic errors and contamination risks, analyte concentration and separation from the sample matrix…

  10. Automatic Procedure to Determine Acidity in Fuel Ethanol by Photometric Titration Using Binary Search and Multicommuted Flow Analysis

    Manoel J. A. Lima e Boaventura F. ReisJournal of the Brazilian Chemical Society2018

    An automatic photometric titration procedure was developed to determine the acidity of fuel ethanol. The procedure was implemented by using a binary search algorithm and a multicommuted flow analysis approach. Solution-handling setup included a homemade syringe pump and a set of solenoid valves, which were assembled…

  11. Frequency analysis of minimum flows

    Adelita Ramaiana Bennemann Granemann, Miriam Rita Moro Mine e Eloy KaviskiRBRH2018

    ABSTRACT The study of minimum flows is increasingly important due to the relationship with ecosystem sustainability, the economy and its role as a sentinel of climate change. The aim of this paper is to contribute to the theoretical treatment of minimum extremes and, specifically, minimum flows. The method has two…

  12. Development of a multicommuted flow analysis procedure for photometric determination of total N-ureide in soybean tissues

    Carla C. Crispino e Boaventura F. ReisJournal of the Brazilian Chemical Society2013

    In the current work, an automated procedure for photometric determination of N-ureide in soybean tissues is described. The photometric procedure was based on the reaction of N-ureide with hypochlorite, followed by its reaction with phenol in an alkaline medium, forming the indophenol blue compound, monitored at 660…

  13. Turbidimetric determination of sulfate in rainwater employing a LED based photometer and multicommuted flow analysis system with in-line preconcentration

    Néstor Zárate, Ricardo Pérez-Olmos e Boaventura Freire dos ReisJournal of the Brazilian Chemical Society2011

    In the present work, an automatic procedure for turbidimetric determination of sulfate in rainwater, based on the multicommuted flow analysis approach, is proposed. The photometer set-up was developed at the laboratory, and includes: a LED (λ = 420 nm), a long pathlength flow cell (100 mm), and a photodiode. A…

  14. Automatic flow analysis procedure for the determination of bromide in L-alanine by chemiluminescence detection

    Eduardo P. Borges e Boaventura F. ReisJournal of the Brazilian Chemical Society2007

    An automatic flow analysis procedure for bromide determination in L-alanine aminoacid employing detection by chemiluminescence is described. The procedure was based on the bromide oxidation by chloramine-T followed by reaction with luminol. Spiking sample with standard solution gave recoveries values ranging from 94…

  15. Chemical analyses of flowers and leaves for nutritional diagnoses of coffee trees

    André Vinicius Zabini, Herminia Emilia Prieto Martinez, Júlio César Lima Neves e mais 2Ciência Rural2021

    ABSTRACT: The chemical analysis of flowers has been studied for some crops. In coffee trees, the flower tissue analysis could anticipate the nutritional diagnosis. This study aimed to: (i) compare the mineral composition of coffee flowers and leaves; and to (ii) generate reference values for nutritional diagnosis of…

  16. Use of a Digital Image in Flow Analysis: Determination of Nitrite and Nitrate in Natural Waters

    Jorge Luís O. Santos, Oldair D. Leite, Anete D. M. Vieira e mais 2Journal of the Brazilian Chemical Society2016

    A webcam is proposed as the detector in a flow system with multicommutation, and the feasibility of the approach is demonstrated in the determination of nitrate and nitrite in natural waters. The typical transient signal inherent to the flow system was obtained using a digital video and quantified by ImageJ software…

  17. A multicommuted flow analysis method for the photometric determination of amoxicillin in pharmaceutical formulations using a diazo coupling reaction

    Sueny K. B Freitas, Valdinete Lins da Silva, Alberto N Araújo e mais 3Journal of the Brazilian Chemical Society2011

    A multicommuted flow analysis method for the spectrophotometric determination of amoxicillin in pharmaceutical formulations is reported. The proposed method is based on the reaction of diazotised o-nitroaniline with amoxicillin in an alkaline medium, producing a yellow compound that was monitored at 435 nm. The main…

  18. Determination of Gaseous Analytes in Flow Systems: A Review

    Celio Pasquini e Maria do Carmo Hespanhol da SilvaJournal of the Brazilian Chemical Society1999

    Efforts to develop flow systems for the determination of gaseous analytes in gaseous samples are critically reviewed. Although flow systems present a suitable alternative to management and processing of gaseous samples, relatively few papers dealing with this subject are found in the literature. The increased demand…

  19. Spectrophotometric flow injection procedure to indirect determination of paracetamol in pharmaceutical formulations using o-tolidine as reagent

    O. Fatibello-Filho e H. J. VieiraEclética Química2008

    A spectrophotometric flow injection method for the determination of paracetamol in pharmaceutical formulations is proposed. The procedure was based on the oxidation of paracetamol by sodium hypochloride and the determination of the excess of this oxidant using o-tolidine dichloride as chromogenic reagent at 430 nm…