acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “electrothermal atomic absorption spectrometry”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Minimization of sample pretreatment for Al, Cu and Fe determination in coconut water by electrothermal atomic absorption spectrometry

    Juliana Naozuka e Pedro V. OliveiraJournal of the Brazilian Chemical Society2006

    Fast and reliable methods for the direct determination of Al, Cu and Fe in unprocessed coconut water by electrothermal atomic absorption spectrometry are proposed. For Fe determination, 100 µL of sample were diluted with 1400 µL of 0.1% v/v HNO3. Aliquots of 10 µL of this solution were injected into the graphite tube…

  2. Dispersive liquid-liquid microextraction based on solidification of floating organic drop for simultaneous separation/preconcentration of nickel, cobalt and copper prior to determination by electrothermal atomic absorption spectrometry

    Mooud Amirkavei, Shayessteh Dadfarnia e Ali Mohammad Haji ShabaniQuímica Nova2013

    A dispersive liquid-liquid microextraction based on solidification of floating organic drop for simultaneous extraction of trace amounts of nickel, cobalt and copper followed by their determination with electrothermal atomic absorption spectrometry was developed. 300 µL of acetone and 1-undecanol was injected into an…

  3. Cu, Fe, Mn and Zn distribution in protein fractions of Brazil-nut, cupuassu seed and coconut pulp by solid-liquid extraction and electrothermal atomic absorption spectrometry

    Juliana Naozuka e Pedro V. OliveiraJournal of the Brazilian Chemical Society2007citado por 2 artigos

    In this work Cu, Fe, Mn and Zn were determined in extracts of Brazil-nut (Bertholletia excelsa), cupuassu (Theobroma grandiflorum) seeds and coconut (Cocos nucifera) pulp, using solid-liquid extraction and electrothermal atomic absorption spectrometry. Different extractant solutions (mixture of methanol and chloroform…

  4. Magnetic Nanoparticles Coated with Ionic Liquid as a Sorbent for Solid Phase Extraction of Chromium(VI) Prior to Its Determination by Electrothermal Atomic Absorption Spectrometry

    Mehdi Karimi, Ali M. H. Shabani e Shayessteh DadfarniaJournal of the Brazilian Chemical Society2016

    A simple, sensitive and reliable method for the separation, preconcentration and determination of ultra trace amounts of chromium species has been developed. Chromium(VI) in aqueous sample was reacted with 9-phenyl-2,3,7-trihydroxy-6-fluorone to produce a chelate at pH of 5.0 and extracted onto the magnetic…

  5. Determination of rhodium and platinum by electrothermal atomic absorption spectrometry after preconcentration with a chelating resin

    F. Sánchez Rojas, C. Bosch Ojeda e J.M. Cano PavónJournal of the Brazilian Chemical Society2007

    The present publication describes a separation/preconcentration procedure for the subsequent trace analysis of rhodium and platinum in environmental samples. A chelating ion-exchange resin was employed for this purpose and an automatic on-line flow injection electrothermal atomic absorption spectrometry (FI-ET-AAS)…

  6. On-line microwave-assisted sample decomposition for lead determination in fish slurry samples by electrothermal atomic absorption spectrometry

    Marco A.Z. Arruda, Anne H. Fostier e Francisco J. KrugJournal of the Brazilian Chemical Society1997

    An on-line microwave-assisted decomposition procedure for the determination of lead in fish is proposed. 300 µL slurry and 400 µL of a 6 mol L-1 HNO3 solution were simultaneously injected, and the mixture was positioned inside a microwave oven. The decomposed sample inside the flushing solution was collected in the…

  7. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    Daniel Andrada, Frederico G. Pinto, Cristina Gonçalves Magalhães e mais 3Journal of the Brazilian Chemical Society2006

    The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ET AAS). Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 µL of…

  8. Arsenic determination in pharmaceutical grade barium sulfate using direct solid sampling electrothermal atomic absorption spectrometry

    Rodrigo C. Bolzan, Diogo P. de Moraes, Julio Cezar P. de Mattos e mais 2Journal of the Brazilian Chemical Society2010

    A method for arsenic determination in pharmaceutical grade BaSO4 by solid sampling electrothermal atomic absorption spectrometry (SoS-ET AAS) is described. Two background (BG) correction systems, deuterium and Zeeman-effect (Z), were evaluated. Background was decreased by using hydrogen combined with Pd. Accurate and…

  9. Determination of metal impurities in carbon nanotubes by direct solid sampling electrothermal atomic absorption spectrometry

    Paola A. Mello, Luiz Frederico Rodrigues, Matheus A. G. Nunes e mais 4Journal of the Brazilian Chemical Society2011

    Metal impurities (Al, Cd, Co, Cr, Cu, Mg, Mn and Pb) were determined in carbon nanotubes (CNTs) by direct solid sampling electrothermal atomic absorption spectrometry (DSS-ET AAS, deuterium lamp background corrector). Parameters as pyrolysis and atomization temperatures, use of Pd as chemical modifier, feasibility of…

  10. Determination of cobalt in wine and must by electrothermalatomization atomic absorption spectrometry: analyticalmethod development and validation

    S. Catarino, A. Neves e R. Bruno de SousaCiência e Técnica Vitivinícola2009

    An electrothermal atomization atomic absorption spectrometry method was optimized to quantify cobalt in musts and wines, especially within quality control scope. As far as wine samples are concerned, the method involves reduced risk of contamination by eliminating prior treatment other than dilution (1:2). For must…

  11. Determination of Cd and Pb in fuel ethanol by filter furnace electrothermal atomic absorption spectrometry

    Tatiana D. Saint'Pierre, Tatiane de A. Maranhão, Vera L. Frescura e mais 2Química Nova2008

    A method was developed for quantification of Cd and Pb in ethanol fuel by filter furnace atomic absorption spectrometry. Filter furnace was used to eliminate the need for chemical modification, to stabilize volatile analytes and to allow the application of short pyrolysis step. The determinations in samples were…

  12. Determination of Copper and Cadmium in Petroleum Produced Formation Water by Electrothermal Atomic Absorption Spectrometry after Cloud Point Extraction

    Valdinei S. Souza, Leonardo S. G. Teixeira, Queila O. Santos e mais 2Journal of the Brazilian Chemical Society2020citado por 1 artigo

    Cloud point extraction (CPE) in association with graphite furnace atomic absorption spectrometry (GF AAS) was proposed for preconcentration and quantification of trace amounts of copper and cadmium in samples of saline produced formation water from petroleum exploration. The procedure was based on the formation of…

  13. Extraction and Separation of Molybdenum by Using Homogeneous Liquid-Liquid Microextraction via Flotation Assistance

    Mohammad Rezaee, Maryam Mozaffari, Hedayat Haddadi e mais 2Journal of the Brazilian Chemical Society2015

    Homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA) was investigated for the extraction of molybdenum from the water samples. Alizarin Red S and cetyl trimethylammonium bromide (CTAB) were used as a complexing ligand and ion-pairing reagent, respectively. The enriched analyte in the floated…

  14. Determination of thallium traces by ETAAS after on-line matrix separation and preconcentration in a flow injection system

    Taherah Asadoulahi, Shayessteh Dadfarnia e Ali Mohammad Haji ShabaniJournal of the Brazilian Chemical Society2007

    A simple and sensitive flow injection system was developed for separation, preconcentration and determination of thallium. Preconcentration is based on the analyte sorption on a microcolumn of dibenzo-18-crown-6 (DB18C6) immobilized on surfactant coated alumina with subsequent elution using a nitric acid solution (500…

  15. Determination of lead by electrothermal atomic absorption spectrometry employing a novel sampling strategy of polyurethane foam impregnated with thiazolylazo-p-cresol (TAC)

    Otoniel D Sant'Ana, Luciene S Jesuino, Ricardo J Cassella e mais 2Journal of the Brazilian Chemical Society2004

    This work presents a method for lead determination by ETAAS, based on solid sampling of polyurethane foam (PUF) impregnated with the reagent 2-(2-thiazolylazo)-p-cresol (TAC) previously utilized to extract the metallic ion from sample solution. The extraction process occurred in a medium buffered in pH 10 with borate…

  16. Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction

    Hugo B. Pereira, Aderval S. Luna, Friedrich W. Herms e mais 1Journal of the Brazilian Chemical Society2004

    A simple method for measuring trace levels of Pb in bone by electrothermal atomic absorption spectrometry is described. It is shown that Pb can be accurately measured with good precision and accuracy using external calibration with aqueous Pb analytical solutions containing NH4H2PO4 as modifier. The detection limit…

  17. Determination of vanadium in urine by electrothermal atomic absorption spectrometry using hot injection and preconcentration into the graphite tube

    Kelly G. Fernandes, Ana Rita A. Nogueira, José A. Gomes Neto e mais 1Journal of the Brazilian Chemical Society2004

    In this work it was developed a procedure for the determination of vanadium in urine samples by electrothermal atomic absorption spectrometry using successive injections for preconcentration into a preheated graphite tube. Three 60 µL volumes were sequentially injected into the atomizer preheated to a temperature of…

  18. Determination of cadmium in sediments and in sewage sludge by slurry sampling electrothermal atomic absorption spectrometry using iridium as permanent modifier

    Daniel L. G. Borges, Lúcia F. Dias, Márcia A. M. S. da Veiga e mais 1Journal of the Brazilian Chemical Society2003

    A procedure for the determination of Cd in sediment and sewage sludge as slurries by electrothermal atomic absorption spectrometry is proposed. The slurry, 1 mg mL-1, was prepared by mixing sample ground to a particle size £ 50 mm with 5% v/v nitric acid in an ultrasonic bath. The homogeneity of the slurries was…