acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “elastography”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Accuracy of transient elastography-FibroScan®, acoustic radiation force impulse (ARFI) imaging, the enhanced liver fibrosis (ELF) test, APRI, and the FIB-4 index compared with liver biopsy in patients with chronic hepatitis C

    Taisa Grotta Ragazzo, Denise Paranagua-Vezozzo, Fabiana Roberto Lima e mais 5Clinics2017citado por 3 artigos

    OBJECTIVES: Although liver biopsy is the gold standard for determining the degree of liver fibrosis, issues regarding its invasiveness and the small amount of liver tissue evaluated can limit its applicability and interpretation in clinical practice. Non-invasive evaluation methods for liver fibrosis can address some…

  2. Can the unnecessary operations for suspected thyroid nodules be avoided by the combined use of the strain ratio and elastography score?

    Orhan Görgülü, Feride Fatma Görgülü e Ayşe Selcan KoçBrazilian Journal of Otorhinolaryngology2021

    Abstract Introduction Only 5%-15% of thyroid surgical specimens are reported as malignant. Most of the operations are performed due to suspicion of malignancy as a result of fine needle aspiration biopsy but invasiveness, non-diagnostic results and potential repeat biopsies are disadvantages of fine needle aspiration…

  3. Second-generation endoscopic ultrasound elastography in the differential diagnosis of solid pancreatic masses: Pancreatic cancer vs. inflammatory mass in chronic pancreatitis

    J. J. Iglesias García, J. Lariño Noia, A. Álvarez Castro e mais 2Revista Española de Enfermedades Digestivas2009citado por 1 artigo

    Endoscopic ultrasonography (EUS) is considered one of the most accurate methods for the diagnosis and staging of pancreatic tumors. EUS-guided fine-needle aspiration (FNA) allows to increase the diagnostic accuracy of EUS in this setting; however, it is technically demanding (a pathologist is also essential) and is…

  4. ULTRASONOGRAPHY, SHEAR WAVE ELASTOGRAPHY AND LIVER HISTOLOGY FOR THE DIFFERENTIAL DIAGNOSIS BETWEEN BILIARY ATRESIA AND OTHER CAUSES OF CHOLESTASIS

    Thais Costa Nascentes QUEIROZ, Rogério Auguto PINTO-SILVA, Eleonora Druve Tavares FAGUNDES e mais 3Arquivos de Gastroenterologia2026

    ABSTRACT Background: Biliary atresia (BA) is the leading cause of cholestatic jaundice in the first months of life. Liver stiffness measurement by shear wave elastography (2D-SWE) could help discriminate BA from other causes of cholestasis. Objectives: To assess the use of abdominal ultrasound with bidimensional shear…

  5. Strain elastography findings of two canine thyroid carcinomas: case reports

    Diego Rodrigues Gomes, Tamiris Disselli, Diana Villa Verde Salazar e mais 6Ciência Rural2026

    ABSTRACT: Thyroid neoplasms are the most common in the endocrine system in dogs, with 60% to 90% diagnosed as carcinomas. Clinical signs are usually due to the involvement of adjacent structures, since they rarely trigger clinical hyperthyroidism. With the use of elastography, it is possible to estimate the stiffness…

  6. Correlation and discriminatory performance of non-invasive serum fibrosis indices according to liver disease etiology using two-dimensional shear wave elastography as reference

    María Elena Galaviz-Valdez, Liliana Torres-González, José Raúl Izaguirre-García e mais 5Clinics2026

    Abstract Background/objectives Non-invasive serum fibrosis indices are widely used for liver fibrosis assessment; however, their correlation with liver stiffness and diagnostic performance may vary according to liver disease etiology. This study aimed to evaluate the etiology-dependent correlation between multiple…

  7. Acoustic radiation force Impulse elastography to aid diagnosis of two canine malignant peripheral nerve sheath tumors

    Igor Cezar Kniphoff da Cruz, Rafael Kretzer Carneiro, Marjury Cristina Maronezi e mais 6Ciência Rural2025

    ABSTRACT: This report described the use of acoustic radiation force impulse (ARFI) elastography in the diagnosis of two cases of canine malignant peripheral nerve sheath tumors. Both patients presented with lameness in the thoracic limb and no response to previous clinical treatment or trauma history. Physical…

  8. Using elastography (Aoustic radiation force impulse) to correlate the effects of age, weight, sex, and Norberg angle on the pectineus muscle of dysplastic dogs

    Juliana Rodrigues Leitão, Bruno Watanabe Minto, Angélica Barreto Leite Tavares e mais 5Ciência Rural2025

    ABSTRACT: Inspired by the possibility of further understanding the role of pectineus muscle in the pathophysiology of hip dysplasia, this study evaluated the correlation between the Norberg angle, weight, sex, and age with the acoustic radiation force impulse (ARFI) elastographic findings of the pectineus muscle in…

  9. The application of transperineal ultrasonography combined with shear wave elastography in the evaluation and monitoring of pelvic floor function in the early stage after total hysterectomy

    Runyan Ji, Jing Wu, Yanqing Xu e mais 1Clinics2025

    Abstract Background To investigate the combined effect of transperineal ultrasound and Shear Wave Elastography (SWE) in the evaluation and monitoring of pelvic floor functions after total hysterectomy. Methods Fifty-two women who planned to undergo total hysterectomy from January 2019 to December 2022 in Nantong Third…

  10. Can elastography predict early allograft dysfunction or loss after liver transplantation? A prospective study of diagnostic accuracy

    Guilherme Marques Andrade, Luiz Marcelo Sá Malbouisson, Denise Paranaguá Vezozzo e mais 5Clinics2025

    Abstract Introduction The imbalance between the demand for liver transplants and the shortage of donors can be addressed by expanding the donor pool, including using extended criteria donors. This strategy may reduce waiting time and list mortality but can increase poor graft function rates, affecting short-term…

  11. Association of liver elastography measurements with poor glycaemic control in elderly patients with type 2 diabetes

    Qian Zhang, Li Cao, Yu-Min Wang e mais 6Archives of Endocrinology and Metabolism2025

    ABSTRACT Objective: The relationship between liver health and glycaemic control in elderly patients with diabetes remains poorly understood. In this study, the value of liver elastography in identifying associations with poor glycaemic control among elderly patients with type 2 diabetes mellitus was investigated…

  12. Liver/spleen magnetic resonance elastography and T1/T2 mapping in chronic liver disease: a prospective study

    Gökhan Mert Özyurt, Kaan Esen, Enver Üçbilek e mais 1Revista da Associação Médica Brasileira2024

    SUMMARY OBJECTIVE: This study aims to compare liver and spleen stiffness measurements using magnetic resonance elastography with T1 and T2 relaxation times in patients with chronic liver disease. METHODS: A total of 75 chronic liver disease patients and 25 healthy volunteers underwent MR. Patients with significant…

  13. Use of transient elastography for hepatic steatosis and fibrosis evaluation in patients with subclinical hypothyroidism

    Milena Tauil Auad Noronha Santos, Cristiane Alves Villela-Nogueira, Nathalie Carvalho Leite e mais 2Archives of Endocrinology and Metabolism2024

    ABSTRACT Objective: To evaluate the association between subclinical hypothyroidism and hepatic steatosis and fibrosis using the noninvasive diagnostic methods transient hepatic elastography (TE) and controlled attenuation parameter (CAP) in patients with subclinical hypothyroidism. Subjects and methods: This was a…

  14. THE ROLE OF ELASTOGRAPHY IN CLINICALLY SIGNIFICANT PORTAL HYPERTENSION

    Angelo Alves de MATTOS, Angelo Zambam de MATTOS, Giovana Dal Pozzo SARTORI e mais 2Arquivos de Gastroenterologia2023

    ABSTRACT This is a narrative review that aims to discuss the importance of elastographic methods in the evaluation of clinically significant portal hypertension (CSPH) in cirrhotic patients, where the authors propose an algorithm for evaluating these patients. In compensated advanced chronic liver disease, the goal is…

  15. Comparison of the fibrosis degree using acoustic radiation force impulse elastography and diffusion-weighted magnetic resonance imaging in chronic hepatitis cases

    Mehmet Serindere, Hatice Tuba Sanal, Mutlu Saglam e mais 3Revista da Associação Médica Brasileira2023

    SUMMARY OBJECTIVE: The aim of this study was to investigate the correlation of fibrosis stages in cases of chronic hepatitis by comparing shear wave elastography and diffusion-weighted magnetic resonance imaging. METHODS: A total of 46 chronic hepatitis patients with an age range of 20-50 years were classified into…

  16. Polycystic Ovary Syndrome and Metabolic Syndrome: Clinical and Laboratory Findings and Non-Alcoholic Fatty Liver Disease Assessed by Elastography

    Claruza Braga Holanda Lavor, Antonio Brazil Viana Júnior e Francisco das Chagas MedeirosRevista Brasileira de Ginecologia e Obstetrícia2022

    Abstract Objective To evaluate the association between polycystic ovary syndrome (PCOS) and metabolic syndrome (MetS), adding liver assessment through elastography and ultrasound, for correlation with non-alcoholic fatty liver disease (NAFLD). Metabolic syndrome occurs in~43% of women with PCOS, and NAFLD is the…

  17. Effect of diet on the measurement of liver elasticity by real-time shear wave elastography in normal subjects

    Jin DING, Li LI e Hong-Yuan XUEFood Science and Technology2022citado por 1 artigo

    Abstract To evaluate the liver stiffness measurement (LSM) of normal people before and after diet using real-time shear wave elastography (SWE), and to explore the effect of diet on liver elasticity. Fifty-four healthy volunteers were selected and 480 mL of a standard diet containing 391 kcal were administrated. The…

  18. Shear wave elastography in early diabetic kidney disease

    Ruken Yuksekkaya, Fatih Celikyay, Mehmet Yuksekkaya e mais 1Revista da Associação Médica Brasileira2022

    SUMMARY OBJECTIVE: This study aimed to analyze the kidneys among the subjects with early stages of type 2 diabetic kidney disease by shear wave elastography quantitatively. METHODS: A total of 108 patients with type 2 diabetic kidney disease and 17 control subjects were enrolled. According to the estimated glomerular…

  19. Risk factors associated with nonalcoholic fatty liver disease evaluated by elastography in patients with type 2 diabetes

    Roselee Pozzan, Ronaldo Gama Pena, Cátia Cristina Silva Sousa Vergara Palma e mais 3Archives of Endocrinology and Metabolism2022

    ABSTRACT Objective: There is controversy about the indication for nonalcoholic fatty liver disease (NAFLD) screening in patients with type 2 diabetes mellitus (T2D). The present study aims to contribute to NAFLD surveillance in patients with T2D, assessing the association of clinical and biological variables with…

  20. Applicability of B-mode ultrasonography, ARFI elastography and contrast-enhanced ultrasound in the evaluation of chronic kidney disease in dogs

    Igor C.K. da Cruz, Beatriz Gasser, Marjury Cristina Maronezi e mais 5Pesquisa Veterinária Brasileira2021

    ABSTRACT: The objective of this study was to verify the applicability of B-mode ultrasonography, ARFI elastography and CEUS in the diagnosis of chronic kidney disease and its Stages in dogs. 24 healthy dogs and 28 with CKD were included. In B-mode, the echogenicity, echotexture and cortico-medullary ratio of the…