acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “debris extrusion”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Influence of Apical Preparation Size and Working Length on Debris Extrusion

    Emmanuel João Nogueira Leal Silva, João M. Teixeira, Nancy Kudsi e mais 3Brazilian Dental Journal2016citado por 2 artigos

    Abstract The aim of this study was to quantitatively evaluate the amount of apically extruded debris by single-file reciprocating instruments with different working lengths and apical preparation sizes. Eighty human single-rooted mandibular incisors were used and conventional access cavities were prepared. Then, the…

  2. Apical extrusion of debris by manual and mechanical instrumentation

    Lilia E. Leonardi, Diana M. Atlas e Guillermo RaidenBrazilian Dental Journal2007

    The aim of the present study was to assess the presence of apically extruded debris and evaluate the influence of canal curvature on the amount of debris produced by manual and mechanical techniques. Forty single-rooted mature teeth with 15 to 30 degree of root canal curvature were selected. The presence of only one…

  3. Apically extruded debris in filling removal of curved canals using 3 NiTi systems and hand files

    Débora Delai, Daiana Boijink, Carolina Bender Hoppe e mais 2Brazilian Dental Journal2018citado por 1 artigo

    Abstract The aim of this study was to assess the amount of apically extruded debris during filling removal with WaveOne Gold (WOG), ProTaper Universal Retreatment (PTR), D-RaCe Retreatment (DRR) or hand files (HF), to compare the working time during filling removal, and to describe failures of NiTi instruments. Forty…

  4. Apically Extruded Debris Using Passive Ultrasonic Irrigation Associated with Different Root Canal Irrigants

    Rodrigo Arruda-Vasconcelos, Marlos Barbosa-Ribeiro, Lidiane Mendes Louzada e mais 2Brazilian Dental Journal2019

    Abstract The present study evaluated the amount of apically extruded debris after chemo-mechanical preparation (CMP) associated with passive ultrasonic irrigation (PUI) using four different root canal irrigants, namely, 6% sodium hypochlorite (NaOCl), 2% chlorhexidine gel + saline solution (2% CHXg+SS), 2%…

  5. Evaluation of Apically Extruded Debris Using Positive and Negative Pressure Irrigation Systems in Association with Different Irrigants

    Marlos Barbosa-Ribeiro, Rodrigo Arruda-Vasconcelos, Fabio L. Fabretti e mais 3Brazilian Dental Journal2018citado por 2 artigos

    Abstract This study evaluated the amount of apically extruded debris after chemo-mechanical preparation (CMP) using positive and negative pressure irrigation systems [Conventional irrigation (CI) and EndoVac (EV)] in association with different irrigants [6% Sodium Hypochlorite (NaOCl), 2% Chlorhexidine gel + saline…

  6. Influence of Clinical Operative Technique on Debris Extrusion of Two Reciprocating Files

    Ayfer Atav Ates, Burçin Arıcan, Luca Testarelli e mais 3Pesquisa Brasileira em Odontopediatria e Clínica Integrada2021

    ABSTRACT Objective: To compare the influence of different clinical operative motions (pecking motion vs. MIMERACI) on apical debris extrusion using WaveOne Gold and EdgeOne Fire reciprocating files in the mesiobuccal canal of extracted molars. Material and Methods: Sixty mandibular molar teeth with curvature less than…

  7. Apical Debris Extrusion by Novel Endostar E5 Compared to Other Commercial Rotary Files: An in Vitro Study

    Ajinkya Mansing Pawar, Bhagyashree Thakur, Jatin Atram e mais 2Pesquisa Brasileira em Odontopediatria e Clínica Integrada2019

    Abstract Objective: To compare the amount of apical debris extrusion in samples instrumented by EndoStar E5, ProTaper Universal, and M-two rotary files. Material and Methods: Forty-five freshly extracted non-carious mandibular premolar teeth with single roots and single canals were acquired, and randomly divided into…

  8. Debris extrusion and foraminal deformation produced by reciprocating instruments made of thermally treated NiTi wires

    Myrna Maria Arcanjo Frota, Ricardo Affonso Bernardes, Rodrigo Ricci Vivan e mais 3Journal of Applied Oral Science2018citado por 3 artigos

    Abstract Objective To evaluate the amount of apically extruded debris, percentage of foraminal enlargement and apical foramen (AF) deformation that occurred during root canal preparation with different reciprocation systems: Reciproc, WaveOne (M-Wire), and ProDesign R (Shape Memory Technology Wire) at two different…

  9. Apical Extrusion of Debris and Irrigants Using Different Irrigation Needles

    Paula Barcellos Silva, Angélica Mohnsam Krolow, Katerine Jahnecke Pilownic e mais 4Brazilian Dental Journal2016citado por 1 artigo

    Abstract This study evaluated the influence of irrigation tip, root canal curvature and final apical diameter on periapical debris and irrigant extrusion during root canal instrumentation. After being classified as mildly or moderately curved, the mesiobuccal root canals of 90 human molars were instrumented. The teeth…

  10. Apical extrusion of debris after hand, engine-driven reciprocating and continuous preparation

    Simone Bonato Luisi, Alice Cunegatti Zottis, Caroline Scheeren Piffer e mais 2Revista Odonto Ciência2010

    PURPOSE: This in vitro study assessed the amount of debris extruded apically after preparation with different techniques. METHODS: Sixty healthy, extracted, human mandibular incisors were randomly divided into 3 groups: Group A - hand crown-down technique; Group B - crown-down technique with enginedriven rotary…

  11. Evaluation of Apically Extruded Debris Using Continuous Rotation, Reciprocation, or Adaptive Motion

    Ozgur Genc Sen, Burcu Bilgin, Sibel Koçak e mais 2Brazilian Dental Journal2018citado por 2 artigos

    Abstract The aim of this study was to compare the amount of apically extruded debris during root canal instrumentation using ProTaper Next (PTN), Twisted File (TF) Adaptive, and Reciproc instruments. Forty-five extracted human maxillary canines were selected and randomly assigned into 3 groups. The root canals were…