acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “cyclic load”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Influence of loading mode on the response of a helical pile subjected to cyclic tensile loads in sand

    Manoel Leandro Araújo e Farias, Yuri Daniel Jatobá Costa, Felipy Lima de Queiroz e mais 2Soils and Rocks2025

    Abstract Helical piles are steel elements consisting of one or more helices placed along a central shaft and installed in the ground through rotation. This study describes a field investigation of the behavior of a helical pile prototype subjected to cyclic tensile loads in a site composed of pure sand layers. During…

  2. Effect of an Opening on Reinforced Concrete Hollow Beam Web Under Torsional, Flexural, and Cyclic Loadings

    Sarah Jabbar, Farzad Hejazi e H. Mahir MahmodLatin American Journal of Solids and Structures2016

    Abstract Hollow sections have been increasingly applied in the construction of buildings, bridges, offshore structures, and towers for passing electrical and mechanical pipes or other utilities. Torsion caused by external force is a weakness of hollow sections that is rarely investigated. In particular, the behavior…

  3. Laboratory study of dynamic mechanical characteristic of granite subjected to confining pressure and cyclic blast loading

    Chenglong He e Jun YangLatin American Journal of Solids and Structures2018

    Abstract To investigate the deformation characteristic of deep rock under cyclic blasting, the static-dynamic loading experimental equipment was set up. The dynamic strain gauges and high-speed (HS) camera were adopted to obtain strain field and the crack propagation of rock under confining pressure of 0 MPa, 5 MPa…

  4. Response of vertical pile group subjected to horizontal cyclic load in soft clay

    S BasackLatin American Journal of Solids and Structures2010

    The environment prevalent in ocean necessitates the piles supporting offshore structures to be designed against lateral cyclic loading initiated by wave action. Such quasi-static load reversal induces deterioration in the strength and stiffness of the soil-pile system introducing progressive reduction in the bearing…

  5. Experimental study and assessment of the structural performance of laced reinforced concrete beams against reverse cyclic loading

    Blessy Grant Christian Johnson, Murugesan Ramasamy e Anandavalli NarayananMatéria (Rio de Janeiro)2024citado por 4 artigos

    This experimental research evaluates the structural performance of laced reinforced concrete beams (LRC-45) in comparison to conventional reinforced concrete beams (RC-90) under reverse cyclic loading. Visual inspection revealed that LRC-45 exhibited superior crack resistance, even at high displacements, unlike RC-90…

  6. The structural performance of slab reinforced with steel and GFRP bars subjected to static and static cyclic load

    Jansi Sheela Sidhardhan e Murugan MadasamyMatéria (Rio de Janeiro)2024

    ABSTRACT The FRP composite has recently emerged as a promising alternative material in the construction industry. The need for lightweight materials with excellent tensile strength and good corrosion resistance has increased focus on composites reinforced with natural or synthetic fibers. This study focuses on the…

  7. Numerical and theoretical analysis of geosynthetic encased stone column composite foundation under cyclic loading

    Junli Gao, Xuelei Xie, Jiajun Wang e mais 2Latin American Journal of Solids and Structures2022

    Abstract In this paper, a model of the composite foundation reinforced with geosynthetic encased stone columns was established using the discrete element method, and the characteristics of its action under cyclic loading were studied. The influence of the length and radius of the pile on the settlement of the…

  8. EXPERIMENTAL INVESTIGATION ON CONCRETE FILLED STEEL TUBULAR COLUMN TO FOUNDATION CONNECTIONS SUBJECTED TO COMBINED AXIAL AND LATERAL CYCLIC LOADING

    B Jothimani e C UmaraniLatin American Journal of Solids and Structures2019citado por 2 artigos

    Abstract This study focuses on performance of CFT column to foundation connections subjected to combined axial and lateral cyclic loading. Experimental investigations were carried out on five specimens with exposed column base and embedded column base connections. The parameters considered were number of stiffeners…

  9. Nonlinear analysis method of concrete structures under cyclic loading based on the generalized secant modulus

    Lívia Ramos Santos Pereira e Samuel Silva PennaRevista IBRACON de Estruturas e Materiais2022

    Abstract A smeared crack model to represent cyclic concrete behavior is presented in this work. The model is based on analytical and experimental studies from the literature and proposes a numerical approach using a new concept, the generalized secant modulus. The monotonic formulation is described, followed by the…

  10. Numerical investigation of the effect of improved endochronic constitutive model on rock material deformation under cyclic loading

    Jian Ming Huang, Shi li Hu, Lu Jun Chen e mais 2Latin American Journal of Solids and Structures2021

    Abstract Rock materials are often subjected to cyclic loads during construction. A full understanding of the deformation behavior of rock under cyclic loads is of great significance in engineering. In this study, by using the endochronic constitutive model proposed by Valanis, the reinforcement function form and…

  11. Numerical modeling of a bolted beam-column connection subjected to cyclic loading

    Ygor Moriel Neuberger, Daniel de Lima Araújo e Marcelo de Araújo FerreiraRevista IBRACON de Estruturas e Materiais2025

    Abstract In precast concrete systems, connections play a crucial role in ensuring structural continuity between elements and contributing to the overall stability of the structure. Among various types, semi-rigid bolted beam-to-column connections are commonly used to reduce on-site construction time. Additionally…

  12. Behaviour under cyclic loading of strengthened beams

    A. P. R. Vaz, I. A. E. Shehata, L. C. D. Shehata e mais 1Revista IBRACON de Estruturas e Materiais2017

    Abstract This work presents a study on the behavior of reinforced concrete beams strengthened in bending by the addition of concrete and steel on their tension side and having expansion bolts as shear connectors at the junction between the beam and the jacket, subjected to a cyclic loading. The experimental program…

  13. Analysis of Stress and Fracture Strength of Zirconia Implants after Cyclic Loading

    Diogo Rodrigues Cruvinel, Renata Espíndola Silveira, Rodrigo Galo e mais 3Materials Research2015

    AbstractThe aim of this study was to manufacture a new zirconia implant (Y-TZP) and to evaluate the fracture strength and stresses generated after cyclic loading compared to titanium implants. Thirty-three zirconia and titanium implants were fabricated. The stress generated around the implants was observed by…

  14. Numerical and experimental study of concrete I-beam subjected to bending test with cyclic load

    Paula de Oliveira Ribeiro, Gustavo de Miranda Saleme Gidrão, Luiz Vicente Vareda e mais 2Latin American Journal of Solids and Structures2020citado por 2 artigos

    Abstract This paper provides guidelines for cyclic loading bending test simulation and modal analysis of a reinforced concrete I-beam. For this purpose, experimental and numerical cyclic bending test were performed. In the experimental study, the natural frequencies of the structure in the intact and damaged states…

  15. Numerical analysis of cyclic loading effect on progressive failure of an earth dam upon a multi-laminate framework

    Hamzeh Rahimi Dadgar, Mohamad Ali Arjomand e Ali ArefniaSoils and Rocks2021

    Abstract In this paper, the progressive failure in an earth dam is evaluated upon a Multi-Laminate framework by considering 10 historical earthquakes in the world, along with their equivalent harmonic cyclic loading. Whenever the framework is given for any suggested plane by direction cosines, it has its certain…

  16. Shear strengthening of reinforced concrete beams using fibre reinforced polymer composites

    Rajamony Iyappan e Madasamy MuruganMatéria (Rio de Janeiro)2024citado por 3 artigos

    ABSTRACT Since fiber-reinforced polymer (FRP) composites are superior to traditional steel reinforcements, they are widely used in advanced concrete technology. By using a combination of fibres and FRP strengthening techniques, RC beams can have increased strength and ductility. The kind, arrangement, composition, and…

  17. Large-scale testing of free-ended piles in unsaturated expansive clays under cyclic and monotonic lateral loading

    Ruan A. Murison, Tiago A. V. Gaspar, Gerhard Heymann e mais 2Soils and Rocks2025

    Abstract This article presents an investigation into the influence of swell on the behaviour of large-scale free-ended piles installed in an unsaturated expansive clay deposit when subjected to lateral loading. A ‘dry’ pile was founded in a profile kept at natural water content conditions, and a ‘wet’ pile was founded…

  18. Load-bearing capacity of screw-retained CAD/CAM-produced titanium implant frameworks (I-Bridge®2) before and after cyclic mechanical loading

    Marc Philipp Dittmer, Moritz Nensa, Meike Stiesch e mais 1Journal of Applied Oral Science2013

    Implant-supported screw-retained fixed dental prostheses (FDPs) produced by CAD/ CAM have been introduced in recent years for the rehabilitation of partial or total endentulous jaws. However, there is a lack of data about the long-term mechanical characteristics. OBJECTIVE: The aim of this study was to investigate the…

  19. Rehabilitation of damaged RC exterior beam-column joint using various configurations of CFRP laminates subjected to cyclic excitations

    Gopalakrishnan Palanisamy e Vidhya KumarasamyMatéria (Rio de Janeiro)2023citado por 7 artigos

    ABSTRACT In this research, an investigational study on the use of CFRP laminates with 4 types of configurations (Series-A: laminated with confinement wrap, Series-B: single flat & L wrap, Series-C: confinement wrap, and Series-D: double flat & confinement wrap) to repair partially damaged reinforced cement composite…