acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “curing light”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Effect of wavelength and radiant emittance on light transmittance and temperature increase in dental resin-based composites

    Sharanya Singh, Mateus Garcia Rocha, Shannon M Wallet e mais 3Journal of Applied Oral Science2025citado por 1 artigo

    Abstract Objectives: To evaluate the effect of wavelength and radiant emittance on light transmittance and heat generation through dental resin-based composites. Methodology: Light-emitting diodes on the blue, green, and red wavelength spectra were assembled and characterized using a spectrometer (MARC Resin…

  2. Residual monomer in a composite resin after light-curing with different sources, light intensities and spectra of radiation

    Ivan A. Filipov e Stoyan B. VladimirovBrazilian Dental Journal2006citado por 7 artigos

    The purpose of this study was to investigate the amount of residual monomer in a composite resin after light-curing with different sources, light intensities and spectra of radiation. The resin specimens (4 mm in diameter; 2 mm thick) (n=5) were inserted in Plexglass matrixes and light-cured with a halogen lamp, LED…

  3. Abrasion resistance of composites polymerized by light-emitting diodes (LED) and halogen light-curing units

    Janisse Martinelli, Fernanda de Carvalho Panzeri Pires-de-Souza, Luciana Assirati Casemiro e mais 2Brazilian Dental Journal2006citado por 2 artigos

    This study compared the abrasion resistance of direct composite resins cured by light-emitting diodes (LED) and halogen light-curing units. Twenty specimens (12 mm in diameter; 1.0 mm thick) of each composite resin [TPH (Dentsply); Definite (Degussa); Charisma (Heraus Kulzer)] were prepared using a…

  4. Effect of light-activation with different light-curing units and time intervals on resin cement bond strength to intraradicular dentin

    Maria Eleonora Miguel-Almeida, Mario Lucio da Costa Azevedo, Fuad Abi Rached-Júnior e mais 3Brazilian Dental Journal2012citado por 5 artigos

    The aim of this study was to assess the bond strength of a resin cement to intraradicular dentin varying the light-curing unit and the moment at which the light was applied. Post spaces of endodontically treated canines were prepared. The roots were distributed into 6 groups (n=10) according to the light-curing unit…

  5. Influence of customization and light-curing device on the bond strength of glass fiber posts - in vitro study

    Gustavo do Prado SCHOENHALS, Larissa Pinceli CHAVES e Fabiana Scarparo NAUFELRevista de Odontologia da UNESP2022

    Abstract Introduction Endodontically treated teeth are usually affected by extensive structure loss requiring the use of intraradicular posts to provide retention and restoration. Objective An in vitro assessment was performed on the bonding of glass fiber posts to the root dentin. Material and method Ninety (n = 10)…

  6. Prototype of a new tip developed to be coupled to dental light-curing units for optimizing bonding of orthodontic brackets and accessories

    Sergio Luiz Mota Júnior, Márcio José da Silva Campos, Marco Abdo Gravina e mais 2Dental Press Journal of Orthodontics2013

    OBJECTIVE: development of a new device to be coupled to light-curing units for bonding orthodontic brackets and accessories, and test its efficacy in an in vitro mechanical trial. The inner surface of the device is mirrored and is based on physical concepts of light refraction and reflection. The main advantage of…

  7. Analysis of gap formation at tooth-composite resin interface: effect of C-factor and light-curing protocol

    Gustavo Oliveira dos Santos, Antônio Henrique Monteiro da Fonseca Thomé da Silva, José Guilherme Antunes Guimarães e mais 3Journal of Applied Oral Science2007citado por 2 artigos

    OBJECTIVE: The aim of this study was to evaluate the effect of C-factor and light-curing protocol on gap formation in composite resin restorations. Material and METHODS: Cylindrical cavities with 5.0 mm diameter and three different depths (A=1.0, B=2.0 and C=3.0 mm) were prepared on the occlusal surface of 30 human…

  8. Effect of light-curing units, post-cured time and shade of resin cement on knoop hardness

    Rogério Vieira Reges, Ana Rosa Costa, Américo Bortolazzo Correr e mais 4Brazilian Dental Journal2009citado por 8 artigos

    The aim of this study was to evaluate the Knoop hardness after 15 min and 24 h of different shades of a dual-cured resin-based cement after indirect photoactivation (ceramic restoration) with 2 light-curing units (LCUs). The resin cement Variolink II (Ivoclar Vivadent) shade XL, A2, A3 and opaque were mixed with the…

  9. Influence of Sealer and Light-Curing Units on Push-Out Bond Strength Of Composite Resin to Weakened Roots

    Adriana Corrêa de Lima, Fuad Jacob Rached-Junior, Natália Spadini de Faria e mais 5Brazilian Dental Journal2016citado por 1 artigo

    Abstract The aim of this study was to assess the influence of sealer and light-curing unit on regional bond strength of resin composite to the weakened roots. Ninety roots of incisors were experimentally weakened, subjected to biomechanical preparation and filled with either Endofill, AH Plus or MTA Fillapex The roots…

  10. Effects of cement-curing mode and light-curing unit on the bond durability of ceramic cemented to dentin

    Sheila Pestana Passos, Rodrigo Othávio Assunção Souza, Silvia Masae Araújo Michida e mais 2Brazilian Oral Research2013

    The aim of this study was to evaluate the effects of different light-curing units and resin cement curing types on the bond durability of a feldspathic ceramic bonded to dentin. The crowns of 40 human molars were sectioned, exposing the dentin. Forty ceramic blocks of VITA VM7 were produced according to the…

  11. LED and Halogen Light Transmission through a CAD/CAM Lithium Disilicate Glass-Ceramic

    Carolina Nemesio de Barros Pereira, Cláudia Silami de Magalhães, Bruno Daleprane e mais 4Brazilian Dental Journal2015citado por 1 artigo

    The effect of thickness, shade and translucency of CAD/CAM lithium disilicate glass-ceramic on light transmission of light-emitting diode (LED) and quartz-tungsten-halogen units (QTH) were evaluated. Ceramic IPS e.max CAD shades A1, A2, A3, A3.5, high (HT) and low (LT) translucency were cut (1, 2, 3, 4 and 5 mm)…

  12. Composite monomer conversion and microhardness using short curing times

    Marcelo Giannini, Eduardo F. de Castro, Beatriz Ometto Sahadi e mais 2Brazilian Dental Journal2025

    Abstract This study evaluated how short curing times affect monomer conversion and microhardness of a bulk-fill composite. Two light-curing units (LCUs) were used: a laser LCU (Monet, AMD Lasers) and a multi-peak LED LCU (PowerCure, Ivoclar Vivadent). A bulk-fill composite (Tetric PowerFill, Ivoclar) was cured for 1…

  13. Light curing in dentistry and clinical implications: a literature review

    Frederick Allen RUEGGEBERG, Marcelo GIANNINI, Cesar Augusto Galvão ARRAIS e mais 1Brazilian Oral Research2017citado por 17 artigos

    Abstract Contemporary dentistry literally cannot be performed without use of resin-based restorative materials. With the success of bonding resin materials to tooth structures, an even wider scope of clinical applications has arisen for these lines of products. Understanding of the basic events occurring in any dental…

  14. Accuracy of Irradiance and Power of Light-Curing Units Measured With Handheld or Laboratory Grade Radiometers

    Marcelo Giannini, Carolina Bosso André, Vanessa Cavalli Gobbo e mais 1Brazilian Dental Journal2019

    Abstract This study measured and compared exitance irradiance and power of 4 commercial dental light-curing units (LCU) (Elipar S10, Elipar DeepCure-S, Corded VALO and Bluephase Style) using different types of radiometers. The devices used to analyze the LCU were classified as either handheld analog (Henry Schein…

  15. Depth of cure of dental composites submitted to different light-curing modes

    Raphael Vieira Monte Alto, José Guilherme Antunes Guimarães, Laiza Tatiana Poskus e mais 1Journal of Applied Oral Science2006citado por 1 artigo

    OBJECTIVE: This study evaluated the depth of cure of five dental composites submitted to different light-curing modes. MATERIAL AND METHODS: Canal-shaped cavities with 5mm of length were prepared on the buccal surfaces of extracted third molars, and restored using P-60, A-110, Admira, Z-250 and Supreme resin…

  16. Effect of different light curing methods on mechanical and physical properties of resin-cements polymerized through ceramic discs

    Isil Cekic-nagas e Gulfem ErgunJournal of Applied Oral Science2011citado por 3 artigos

    OBJECTIVE: The aim of this study was to compare the polimerization ability of three different light-curing units (quartz tungsten halogen, light-emitting diodes and plasma arc) and their exposure modes (high-intensity and soft-start) by determination of microhardness, water sorption and solubility, and diametral…

  17. Effect of different light-curing devices and aging procedures on composite knoop microhardness

    Fernanda Regina Voltarelli, Claudia Batitucci dos Santos-Daroz, Marcelo Corrêa Alves e mais 2Brazilian Oral Research2009citado por 4 artigos

    The aim of this study was to evaluate the effect of light-curing devices (Halogen/HAL, Light Emitting Diodes/LED, Argon Laser/LAS and Plasma Arc/PAC) and aging procedures (Mechanical Cycling/MC, Thermal Cycling/TC, Storage/S, MC+TC and MC+TC+S) on the micro-hardness of bottom/B and top/T surfaces of 2-mm-high…

  18. Influence of Photoinitiator and Light-Curing Source on Bond Strength of Experimental Resin Cements to Dentin

    Dario Raimundo Segreto, Fabiana Scarparo Naufel, William Cunha Brandt e mais 3Brazilian Dental Journal2016citado por 6 artigos

    Abstract This study evaluated the bond strength (BS) of experimental resin cements formulated with different photoinitiators when activated by two kinds of light-curing units (LCUs) through a ceramic material. Seven resin blends with different camphorquinone (CQ) and/or phenylpropanedione (PPD) concentrations (weight)…

  19. Effect of Light-Curing Unit Type and Bulk-Fill Composite Resins with Different Photoinitiators on Marginal Gaps of Class II Restorations

    Fereshteh Naser Alavi, Farideh Darabi, Ashkan Salari e mais 1Pesquisa Brasileira em Odontopediatria e Clínica Integrada2022

    Abstract Objective: To evaluate the effect of two types of light-curing units (second and third generations) and two types of bulk-fill composite resins with different photoinitiators - Tetric N-Ceram Bulk Fill (TNCB) and Xtra Fil (XTF) on gap formation at the gingival margins of Cl II restorations. Material and…

  20. Influence of a new light-curing system with optical fiber on the cementation of 3D-printed intraradicular posts

    Mariana Fernanda SOUZA, Juliana de Freitas Gouveia SILVA, Carolina Gonzales FRANÇA e mais 2Brazilian Dental Science2026

    ABSTRACT Objective To evaluate the bond strength between root dentin and composite resin associated with a 3D-printed intraradicular post customized with flowable resin, using a fiber optic light-curing system that photoactivates the resin from within the post. Material and Methods Thirty bovine teeth were used and…