acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “connectors”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Experimental Investigation of Shear Transfer in Precast Lightweight Concrete Sandwich Slabs with Demountable Bolted Steel Shear Connectors

    Rana H. Alkerwei, SA Osman, Ammar N. Hanoon e mais 1Latin American Journal of Solids and Structures2025

    Abstract In this study, three types of bolted shear connectors (I, V, and X type) were proposed. Push-out tests were performed to investigate the shear behaviour of the Precast Lightweight Concrete Sandwich Slab (PLCSS), whose layers were connected by the suggested connectors. Nine specimens of PLCSS were fabricated…

  2. Evaluation of production quality and mechanical behavior of low-cost shear connectors manufactured with perforated GFRP plates

    John Kennedy Fonsêca Silva, Renan Rocha Ribeiro e Rodrigo de Melo LameirasRevista IBRACON de Estruturas e Materiais2021

    abstract: Insulated pre-cast concrete wall panels, also called sandwich panels, consist in two external concrete layers, in which an internal layer of thermal insulation material is inserted between, aiming better acoustic and thermal performance. One of the main concerns regarding the performance of these panels…

  3. Experimental analysis of composite dowels connectors applied in concrete filled steel tubes columns of slender-section

    Rafael Eclache Moreira de Camargo, Lucas Ribeiro dos Santos, Ana Paula Moura e mais 2Revista IBRACON de Estruturas e Materiais2026

    Abstract This research makes a novel and relevant contribution to the field of steel–concrete composite structures by investigating the behavior of Puzzle-shaped (PZ) and Clothoid-shaped (CL) shear connectors, which act as load-transfer devices in circular concrete-filled steel tube (CFST) columns with slender…

  4. Behaviour of hybrid precast reinforced concrete beam-column connections with steel sections under cyclic loading

    Vasanthakumar Tharmarajan, Kalpana Varatharajapuram Govindarajulu e Sasikumar PalanisamyMatéria (Rio de Janeiro)2025

    ABSTRACT This research presents an experimental and analytical investigation of an interior precast beam-column connection using a hybrid steel connector. The beam-column connections were introduced with different positive and negative reinforcement alignments to achieve behaviour comparable to a monolithic reinforced…

  5. Shear test method for characterization of plate connectors applied to concrete-filled steel tube columns and reinforced concrete columns

    Rafael Eclache Moreira de Camargo, Lucas Ribeiro dos Santos, Rodrigo Barreto Caldas e mais 1Revista IBRACON de Estruturas e Materiais2025

    Abstract Shear connectors are often evaluated using the push test method prescribed by EN 1994-1-1:2004. This method is recommended for analyzing connectors applied to composite steel and concrete beams. However, in situations where connectors are employed in other structural elements, the European standard recommends…

  6. Experimental analysis of the structural behavior of different types of shear connectors in steel-concrete composite beams

    Juliano Geraldo Ribeiro Neto, Gregório Sandro Vieira e Rogers de Oliveira ZoccoliRevista IBRACON de Estruturas e Materiais2020

    ABSTRACT: The present work aims to compare the structural behavior of steel-concrete composite-section beams for three types of shear connectors made of U hot rolled section and cold-formed sections of U and L. Experimental tests were performed with the three types of connectors associated with I section laminated…

  7. Slabs strengthened for punching shear with post-installed steel and CFRP connectors

    M. J. M. PEREIRA FILHO, M. V. P. FREITAS, D. F. A. SANTOS e mais 2Revista IBRACON de Estruturas e Materiais2019

    Abstract Structural accidents due to punching shear failures have been reported in flat slab buildings. Design recommendations presented by codes can lead to entirely different punching shear resistance estimates for similar situations. Furthermore, design codes do not present guidelines for the design of punching…

  8. Experimental evaluation on the structural behavior of truss shear connectors in composite steel-concrete beams

    W. C. S. BARBOSA, L. M. BEZERRA, L. CHATER e mais 1Revista IBRACON de Estruturas e Materiais2019

    Abstract The composite structures have great advantages in terms of structural and constructive aspects, with the shear connectors being decisive for obtaining the interaction between the structural elements and for the distribution of the stresses in the structure, taking advantage of the potentiality of each…

  9. Experimental study of RC beams strengthened for bending by reinforced grout layer and connectors

    J. H. CANAVAL, T. J. DA SILVA e A. C. SANTOSRevista IBRACON de Estruturas e Materiais2018

    Abstract This work is based on an experimental investigation of reinforced concrete beams strengthened to flexure for wrapping applying a type of metallic connector in the bond substrate/groute. The experimental program consisted of 5 beams used for reference (without strengthening), 5 beams reinforced with surface…

  10. Crestbond shear connectors for load transfer in concrete filled tube columns

    O. P. AGUIAR, R. B. CALDAS, F. C. RODRIGUES e mais 2Revista IBRACON de Estruturas e Materiais2018citado por 5 artigos

    Abstract This paper presents an experimental study with numerical modeling of Crestbond shear connectors in concrete filled tube columns. The Crestbond, which consists in a steel plate with regular cuttings, was originally conceived for composite beams and is now being proposed as an alternative device for load…

  11. Bolted Shear Connectors Performance in Self-Compacting Concrete Integrated with Cold-Formed Steel Section

    Mustapha Muhammad Lawan, Mahmood Md. Tahir e Jahangir MirzaLatin American Journal of Solids and Structures2016citado por 1 artigo

    Abstract In conventional composite construction involving hot-rolled steel section, the composite action is usually achieved by using conventional headed shear studs connectors. However, use of headed studs is not practical for cold-formed steel (CFS) section due to its very thin form that is difficult to weld. A…

  12. Estimation of friction contribution in the behavior of steel-concrete composite beams with flexible shear connectors

    Gilson Queiroz, Hermes Carvalho, Francisco Rodrigues e mais 1Rem: Revista Escola de Minas2014

    A shear connector, developed to be applied to a composite beam whose steel profile is a thin-walled box profile, displayed much greater flexibility than the conventional welded shear connector, leading to particular issues in the composite beam behaviour. One of these issues is the role played by friction at the…

  13. Experimental analysis of reinforced concrete columns strengthened with self-compacting concrete and connectors

    P. P. Nascimento, R. B. Gomes, L. L. J. Borges e mais 1Revista IBRACON de Estruturas e Materiais2012

    There are many problems involving cases of destruction of buildings and other structures. The columns can deteriorate for several reasons such as the evolution and changing habits of the loads. The experimental phase of this work was based on a test involving nine reinforced concrete columns under combined bending and…

  14. Reduction of Klebsiella pneumoniae bacterial load after active disinfection of venous catheter connectors

    Camila Biazus-Dalcin, Thaís Cristine Marques Sincero, Jefferson Wildes da Silva Moura e mais 5Revista Brasileira de Enfermagem2026

    ABSTRACT Objective: to verify the effectiveness of active disinfection in reducing the bacterial load of Klebsiella pneumoniae inoculated in two types of needleless connectors. Method: an in vitro experimental study was carried out with 84 experiments. The disinfection treatments used were sterile gauze with 70%…

  15. A literature review on the ambient and post-fire behavior of load transfer mechanisms in columns

    Rafael Eclache Moreira de Camargo, Rodrigo Barreto Caldas e Lucas Ribeiro dos SantosAmbiente Construído2026

    Abstract The definition of load transfer mechanisms between beams and columns remains one of the main challenges in developing composite and hybrid structural systems. Although conventional shear connectors such as headed studs are well established, alternative devices like composite dowels have recently gained…

  16. Composite dowels shear connectors for steel-concrete composite beams: a review

    João Vitor Fioresi Altoé, Camila Spagnol de Faria, Mateus Couri Petrauski e mais 3Revista IBRACON de Estruturas e Materiais2025citado por 2 artigos

    Abstract Composite dowels are shear connectors primarily used in steel-concrete composite beams for building and prefabricated composite bridge construction. This paper aims to investigate the current state-of-the-art and contribute to the development of the topic. The following contributions are derived from this…

  17. Design and experimental analysis of a steel-concrete connection with steel block shear connectors

    Caio Lopes Pereira, Gustavo de Souza Veríssimo, Paloma Renata Parassen e mais 1Revista IBRACON de Estruturas e Materiais2025

    Abstract Hybrid structures require efficient connections to transfer forces between elements composed of different materials, ensuring the desired structural performance. Among the available solutions, shear connectors play a crucial role in linking dissimilar materials, motivating ongoing research and the development…

  18. Experimental performance of CA-50 steel shear connectors for composite structures in steel profiles and reinforced concrete

    Vanessa Carolaine de Sousa, Arthur dos Reis Lemos Fontana e Aarão Ferreira Lima NetoRevista IBRACON de Estruturas e Materiais2024

    Abstract Shear connectors are essential elements in composite structures of steel and concrete as they ensure the interaction between materials and the transfer of forces. In this research, seven models of shear connectors made from bent CA-50 steel bars were tested. The models varied in bar diameter, reinforcement…