acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “composite electrode”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Electrochemical Oxidation of Landfill Leachate: Investigation of Operational Parameters and Kinetics Using Graphite-PVC Composite Electrode as Anode

    Zainab H. Mussa, Mohamed R. Othman e Md P. AbdullahJournal of the Brazilian Chemical Society2015

    The preparation of a new carbon composite electrode constructed from graphite-polyvinyl chloride (graphite-PVC) compressed mixtures was used for the first time to treat landfill leachate in Malaysia under electrochemical oxidation. The electrochemical oxidation of landfill leachate was studied on graphite-PVC and Pt…

  2. Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrode

    Carolina M. F. Calixto, Priscila Cervini e Éder T. G. CavalheiroJournal of the Brazilian Chemical Society2012

    A bare graphite-polyurethane composite was evaluated in the tetracycline (TC) determination in natural water samples. Using differential pulse voltammetry (DPV), a linear response was observed in the range of 4.00-40.0 µmol L-1 with limit of detection of 2.80 µmol L-1, without the need of surface renewing between…

  3. Preparation and Characterization of a PVC/TTF-TCNQ Composite Electrode: Applications in a Flow Injection System

    Manuel Cano, Beatriz Palenzuela e Rafael Rodríguez-AmaroPortugaliae Electrochimica Acta2007

    It was prepared a new polyvinyl chloride (PVC)/tetrathiafulvalene-tetracyanoquinodimethane (TTF-TCNQ) composite electrode which showed good physical and electrochemical characteristics. Different PVC/TTF-TCNQ-graphite proportions were tested and the relation 1/10 (p/p) PVC/TTF-TCNQ provided the best results in terms…

  4. Determination of paracetamol at a graphite-polyurethane composite electrode as an amperometric flow detector

    Priscila Cervini e Éder Tadeu Gomes CavalheiroJournal of the Brazilian Chemical Society2008

    A bare graphite-polyurethane composite was evaluated as an amperometric flow injection detector in the determination of paracetamol (APAP) in pharmaceutical formulations. A linear analytical curve was observed in the 5.00 x 10-5 to 5.00 x 10-3 mol L-1 range with a minimum detectable net concentration of 18.9 µmol L-1…

  5. A Simple and Sensitive Non Modified Acetylene Black-Polyurethane Composite Electrode in the Determination of Bisphenol-A in Water Samples

    Rafael da Silva, Priscila Cervini e Éder T. G. CavalheiroJournal of the Brazilian Chemical Society2024

    A new composite based on acetylene black (AB) and vegetable derivative polyurethane (PU) was prepared and evaluated in the determination of bisphenol A (BPA) in water samples using a differential pulse voltammetric procedure (DPV). DPV pulse amplitude of 50 mV, 10 mV s-1 scan rate and 0.10 mol L-1 phosphate buffer…

  6. The use of a graphite-silicone rubber composite electrode in the determination of rutin in pharmaceutical formulation

    Sidney X. dos Santos, Luiz H. Mazo e Éder T. G. CavalheiroJournal of the Brazilian Chemical Society2008citado por 1 artigo

    The possibility of using a graphite silicone-rubber composite electrode (GSR) in a differential pulse voltammetric(DPV) procedure for rutin (vitamin P) determination is described. Cyclic voltammograms of rutin presented a reversible pair of oxidation/reduction peaks respectively at 0.411 and 0.390 V (vs. SCE) at the…

  7. Using of a graphite-polyurethane composite electrode modified with a Schiff base as a bio-inspired sensor in the dopamine determination

    Sidney X. dos Santos e Éder T. G. CavalheiroJournal of the Brazilian Chemical Society2014

    A solid composite electrode based on graphite and polyurethane resin modified with a copper(II) complex of the symmetrical tetradentate Schiff's base type, N, N'-ethylenebis(salicylideneiminato) copper(II) ([Cu(II)Salen]), was evaluated as a bio-inspired sensor using dopamine (DA) as a model analyte. The voltammetric…

  8. Square-wave voltammetric determination of rutin in pharmaceutical formulations using a carbon composite electrode modified with copper (II) phosphate immobilized in polyester resin

    Kellen Heloizy Garcia Freitas, Orlando Fatibello-Filho e Ivanildo Luiz de MattosBrazilian Journal of Pharmaceutical Sciences2012

    A carbon composite electrode modified with copper (II) phosphate immobilized in a polyester resin (Cu3(PO4)2-Poly) for the determination of rutin in pharmaceutical samples by square-wave voltammetry is described herein. The modified electrode allows the determination of rutin at a potential (0.20 V vs. Ag/AgCl (3.0…

  9. A New Electrochemical Platform Based on a Polyurethane Composite Electrode Modified with Magnetic Nanoparticles Coated with Molecularly Imprinted Polymer for the Determination of Estradiol Valerate in Different Matrices

    Bruna Bergamin, Rafael R. Pupin, Ademar Wong e mais 1Journal of the Brazilian Chemical Society2019

    A polyurethane composite electrode modified with magnetic nanoparticles (mag; Fe3O4) coated with molecularly imprinted polymers (MIPs) was developed for the electrochemical determination of estradiol valerate. Chemical and morphological analyses of the mag-MIP were performed using scanning electron microscopy (SEM)…

  10. Preparation of a composite particle electrode by electroless plating and its electrocatalytic performance in the decolorization of methyl orange dye solution

    Guiping Cao, Feng Xu e Shengan XiaJournal of the Brazilian Chemical Society2013

    A nickel-loaded activated carbon (Ni/AC) composite particle electrode was prepared by electroless deposition with palladium-free pretreatment to improve the electrocatalytic performance of a composite particle electrode in a three-dimensional electrode cell. The preparation conditions of the Ni/AC particle electrode…

  11. Simultaneous voltammetric determination of acetaminophen and caffeine at a graphite and polyurethane screen-printed composite electrode

    Thalita R. Saciloto, Priscila Cervini e Éder T. G. CavalheiroJournal of the Brazilian Chemical Society2013

    A selective electrochemical method was developed for the individual or simultaneous determination of acetaminophen and caffeine in phosphate buffer pH 6.0 on graphite and polyurethane screen-printed composite electrode (EIGPU) using Differential Pulse Voltammetry (DPV). The oxidation peaks of acetaminophen and the…

  12. Potentiostatic Co-deposition of Nickel and Graphite Using a Composite Counter Electrode

    B. Aremo, M.O. Adeoye e I. B. ObiohPortugaliae Electrochimica Acta2019

    Nickel and graphite were potentiostatically co-deposited using a nickel-graphite composite counter electrode (HCE) with tunable-friability. Graphite electrodes were produced at densities of 0.920, 1.026 and 1.188 g/cm³, and their suitability for constitution into HCE was assessed. The surface area of the nickel…

  13. SUPPORT EFFECT ON THE STRUCTURE AND PROPERTIES OF MANGANESE OXIDE ELECTRODE MATERIALS

    Huatao Wu, Yongjun Han, Li Wang e mais 2Química Nova2017

    The composite electrode material of manganese oxide supported on poly glucose (PGS) was prepared by using KMnO4 as manganese source. In order to study the influence of the support on the structure and properties of the composite electrode materials, the changes of the composition of the composite electrode materials…

  14. Life and failure of oriented carbon nanotubes composite electrode for resistance spot welding

    Zhong Zheng, Jiafeng Tao, Xing Fang e mais 1Matéria (Rio de Janeiro)2023citado por 3 artigos

    ABSTRACT In view of the poor weldability of electrodes in resistance spot welding (RSW) of galvanized steel sheets, the life of oriented multi-walled carbon nanotubes reinforced Cu matrix composites (Cu@MWCNTs/Cu) electrodes was studied, in which Cu coated multi-walled carbon nanotubes (MWCNTs) are arranged along the…

  15. Electrosynthesis and catalytic activity of polymer-nickel particles composite electrode materials

    Tahar Melki, Ahmed Zouaoui, Barkahoum Bendemagh e mais 5Journal of the Brazilian Chemical Society2009

    Nickel-polymer composite electrode materials have been synthesized using various strategies, all comprising the electrochemical reduction of nickel(II) cations or complexes, incorporated by either ion-exchange or complexation into various poly(pyrrole-carboxylate) thin films coated by oxidative electropolymerization…

  16. Improvement of electrochemical performance of LiMn2O4 composite cathode by ox-MWCNT addition for Li-ion battery

    Su-qin Liu, Jian-feng Zhang, Ke-long Huang e mais 1Journal of the Brazilian Chemical Society2008

    Oxidized multi-walled carbon nanotubes (ox-MWCNT) were used as conducting addition to prepare a novel network composite cathode for lithium ion battery. The morphology was analyzed by scanning electron microscope, LiMn2O4 active particles were connected by ox-MWCNT with the formation of three-dimensional networking…

  17. Evaluation of a Graphite-Polyurethane Composite Electrode Modified with Copper Nanoparticles as an Amperometric Flow Detector in a Wall-Jet System for the Determination of Cysteine

    Isabela A. Mattioli, Letícia F. L. Schildt, Priscila Cervini e mais 2Journal of the Brazilian Chemical Society2020

    A graphite-polyurethane composite electrode (GPUE) was modified by electrodeposition of copper nanoparticles (CuNP) followed by electrochemical treatment in NaOH (GPUE-CuNP), in order to prepare an amperometric sensor for the determination of cysteine (Cys). Cyclic votammograms of Cys solutions at GPUE-CuNP allowed…

  18. DEVELOPMENT OF A VOLTAMMETRIC METHOD FOR THE SIMULTANEOUS DETERMINATION OF PESTICIDES IN SURFACE WATER USING A COMPOSITE ELECTRODE

    Gleiciane Barros Ferreira da Silva, Mateus Ferreira Amaral, Felipe Perin Bezerra e mais 2Química Nova2024

    A method was developed and validated for the simultaneous quantification of pesticides carbendazim (CBZ), diuron (DI) and carbofuran (CF) in surface water using a sustainable, handmade, and low-cost composite electrode (CE) based on graphite and polycaprolactone (PCL). The cyclic voltammetric (CV) results showed a…

  19. Epoxy/Graphite Composite Electrode Modified with Recycled Silver Nanoparticles: An Eco-Friendly Strategy to Improve Lead Detection

    Taíssa S. Cabral, Suéllen F. L. do Nascimento, Lucas V. de Faria e mais 6Journal of the Brazilian Chemical Society2023

    In this work, silver nanoparticles (AgNPs) obtained from photographic waste were synthesized and electrodeposited via cyclic voltammetry using epoxy-graphite composite as an electrochemical substrate. Both electrodes, unmodified (Epoxy/C) and modified (Epoxy/C/AgNPs), were characterized electrochemically by…