acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “complete dentures”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Modified functional impression technique for complete dentures

    Alexandre Malachias, Helena de Freitas Oliveira Paranhos, Cláudia Helena Lovato da Silva e mais 2Brazilian Dental Journal2005citado por 1 artigo

    This report describes the use of a removable acrylic resin tray handle that can be easily attached to custom impression trays to produce an improved peripheral sealing zone. This device can be indicated to develop functional impressions for complete dentures using the patient-conducted muscular motion technique. In…

  2. Evaluation of surface roughness, wettability and adhesion of multispecies biofilm on 3D-printed resins for the base and teeth of complete dentures

    Beatriz de Camargo POKER, Viviane de Cássia OLIVEIRA, Ana Paula MACEDO e mais 3Journal of Applied Oral Science2024citado por 1 artigo

    Abstract Studies evaluating the roughness, wettability and microbial adhesion of 3D-printed resins for complete denture bases and teeth are scarce. Objective This study evaluated the surface roughness, wettability and adhesion of multispecies biofilms (Candida albicans, Staphylococcus aureus and Streptococcus mutans)…

  3. Changes in occlusal vertical dimension in microwave processing of complete dentures

    Débora Barros Barbosa, Marco Antonio Compagnoni e Cláudio Rodrigues LelesBrazilian Dental Journal2002citado por 4 artigos

    This study investigated the effect of different microwave curing cycles on the changes in occlusal vertical dimension of complete dentures. Four test groups with 12 maxillary dentures each were evaluated. Groups 1, 2 and 3 were polymerized with different cycles by microwave radiation and Group 4 was the control and…

  4. Nutritional and anthropometric analysis of edentulous patients wearing implant overdentures or conventional dentures

    Katia Muller, José Morais e Jocelyne FeineBrazilian Dental Journal2008citado por 4 artigos

    As masticatory efficiency diminishes drastically in edentulous patients, several researchers have studied over the past two decades how dietary intake varies when different types of oral rehabilitation are provided. Since the use of implants to support prostheses in edentulous mandibles has been shown to significantly…

  5. Comparative study of methods for the quantification of biofilm on complete dentures

    Helena de Freitas Oliveira Paranhos e Cláudia Helena Lovato da SilvaBrazilian Oral Research2004citado por 4 artigos

    This study compared the application and reliability of 4 methods for biofilm quantification (computerized, paper-weighing, point-counting, and planimetric) in complete dentures, verifying the correlation between them. The internal surfaces of 62 complete dentures were stained (5% erythrosine) and photographed. The…

  6. Dimensional stability of distances between posterior teeth in maxillary complete dentures

    Rafael Leonardo Xediek Consani, Marcelo Ferraz Mesquita, Lourenço Correr-Sobrinho e mais 1Brazilian Oral Research2006

    The aim of this study was to assess the displacement of posterior teeth in maxillary complete dentures stored in water at 37°C. Twenty acrylic resin-based maxillary complete dentures were constructed with the anterior teeth arranged in normal overlap and the posterior teeth in Angle class I. Metallic pins were…

  7. Kinesiographic study of mandibular movements during functional adaptation to complete dentures

    Cláudio Rodrigues Leles, Marco Antonio Compagnoni, Raphael Freitas de Souza e mais 1Journal of Applied Oral Science2003citado por 1 artigo

    After complete denture insertion, edentulous patients usually present transitory difficulties. This is one of the most critical stages of prosthetic treatment and it is strongly related to the prostheses acceptance. The aim of this study was to evaluate potential changes in the mandibular movement pattern related to…

  8. Efficacy of three denture brushes on biofilm removal from complete dentures

    Roseana Aparecida Gomes Fermandes, Cláudia Helena Lovato - Silva, Helena de Freitas Oliveira Paranhos e mais 1Journal of Applied Oral Science2007citado por 1 artigo

    The aim of this study was to compare the efficacy of three denture brushes (Bitufo-B; Medic Denture-MD; Colgate-C) on biofilm removal from upper and lower dentures using a specific dentifrice (Corega Brite). The correlation between biofilm levels on the internal and external surfaces of the upper and lower dentures…

  9. Short implants to support mandibular complete dentures - photoelastic analysis

    Marcele Jardim PIMENTEL, Wander José da SILVA e Altair Antoninha DEL BEL CURYBrazilian Oral Research2017

    Abstract This study evaluated the stress behavior around short implants in edentulous atrophic mandibles. Six groups included implants with two diameters regular and wide (4 and 5 mm) and three lengths (5, 7 and 9 mm) as follows: Ci9 (9 x 4 mm), Ci7 (7 x 4 mm), Ci5 (5 x 4 mm), Wi9 (9 x 5 mm), Wi7 (7 x 5 mm) and Wi5 (5…

  10. Digital mapping of post-insertion adjustments in complete dentures

    João Afonso Kenhyti SATO, Carolina Mayumi IEGAMI, Yolanda de Toledo Salvado da RESSURREIÇÃO e mais 3Brazilian Dental Science2026

    ABSTRACT Objective Quantitative data regarding complete dentures (CDs) adjustments may support more predictable treatment outcomes and reduce the need for follow-up visits. The purpose of this observational study was to digitally evaluate the magnitude and distribution of postinsertion adjustments in complete…

  11. The role of polymerization cycle and post-pressing time on tooth movement in complete dentures

    Wagner Araujo de Negreiros, Rafael Leonardo Xediek Consani, Marcus Aurelio Rabelo Lima Verde e mais 2Brazilian Oral Research2009

    This study analyzed the influence of polymerization cycle and post-pressing time on tooth movement in complete dentures. Forty maxillary complete dentures were fabricated and randomly assigned to 8 groups (n = 5); the polymerization cycle (conventional long cycle in water bath, fast cycle in boiling water, and by…

  12. 3D-printed CAD/CAM complete dentures - Case report

    Isabel Gomes, João Paulo Martins, Cátia Branco e mais 1Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial2024

    Abstract Dentures are used to restore missing teeth and are traditionally fabricated using the lostwax technique. The flasking process is arduous, time-consuming, error-prone, and requires a skilled technician. The development of 3D printing technology has made rapid prototyping of dentures more feasible. This case…

  13. Influence of one- or two-stage methods for polymerizing complete dentures on adaptation and teeth movements

    Moises NOGUEIRA, Conrado Reinoldes CAETANO, Americo CORRER e mais 3Revista de Odontologia da UNESP2016

    Abstract Introduction The quality of complete dentures might be influenced by the method of confection. Objective To evaluate the influence of two different methods of processing muco-supported complete dentures on their adaptation and teeth movements. Material and method Denture confection was assigned in two groups…

  14. Influence of Inner Circular Sealing Area Impression Method on the Retention of Complete Dentures

    Cun-Wei Wang, Qi Shao, Hui-Qiang Sun e mais 4Brazilian Dental Journal2015

    The aims of the present study were to describe an impression method of "inner circular sealing area" and to evaluate the effect of the method on retention, aesthetics and comfort of complete dentures, which lack labial base for patients with maxillary protrusions. Three patients were subjected to the experiment, and…

  15. Reliability of EMG activity in complete denture users during simulation of activities of daily living

    Simone Michielon Baldisserotto, Dúcia Caldas Cosme da Trindade, Jefferson Fagundes Loss e mais 1Revista Odonto Ciência2010

    PURPOSE: To describe a kinesiologic EMG method and determine the reliability of EMG activity of representative muscles of mastication (temporal, masseter), posture of neck (sternocleidomastoid, trapezius) and trunk (rectus abdominis, paravertebral), and lower extremity strength (rectus femoris, medial gastrocnemius)…

  16. Comparison of two cleansing pastes for the removal of biofilm from dentures and palatal lesions in patients with atrophic chronic candidiasis

    Marcela Cristina Damião Andrucioli, Leandro Dorigan de Macedo, Heitor Panzeri e mais 2Brazilian Dental Journal2004citado por 4 artigos

    The efficacy of 2 oral hygiene products, an experimental toothpaste specific for complete denture cleansing and a regular standard toothpaste, was compared in terms of denture biofilm removal and cure of palatal lesions in patients with atrophic chronic candidiasis. The degree of correlation between presence of…

  17. Evaluation of Bite Force and Masticatory Performance: Complete Denture vs Mandibular Overdenture Users

    Anna Paula da Rosa Possebon, Alessandra Julie Schuster, Amália Machado Bielemann e mais 3Brazilian Dental Journal2020citado por 2 artigos

    Abstract: This cross-sectional observational study with 24 patients evaluated differences in bite force (BF) and masticatory performance (MP) between conventional complete denture (CCD) and implant mandibular overdenture (IMO) users and the correlation between these variables. The BF test was performed bilaterally…

  18. User satisfaction with complete dentures made by the public network of a city in southern Santa Catarina

    Felipe Cechinel VERONEZ, Fernanda Guglielmi Faustini SÔNEGO, Renan Antonio CERETTA e mais 2RGO - Revista Gaúcha de Odontologia2014citado por 1 artigo

    OBJECTIVE: To assess user satisfaction with complete dentures made and delivered in 2010 by the public health care network of a city in the south of Santa Catarina. METHODS: This cross-sectional, observational, descriptive study used the Oral Health Impact Profile - 14 questionnaire to collect data. The questionnaire…

  19. Adaptation of complete denture bases submitted to chemical polishing

    Márcia Gomes, Josué Ricardo Broilo, Luiz Fernando Walber e mais 2Journal of Applied Oral Science2004

    OBJECTIVE: This study evaluated the effect of chemical polishing on the internal adaptation of complete denture bases fabricated with Veracril® resin and polymerized by either the conventional (C) or microwave (M) techniques. MATERIAL AND METHODS: Six groups (n=6/group) were tested: 1) C + no polishing (CO); 2) C +…

  20. Dental displacement in complete dentures influenced by different flask types and polymerization cycles

    Conrado Reinoldes Caetano, Ricardo Armini Caldas, Anna Gabriella Camacho Presotto e mais 3Brazilian Dental Journal2021

    Abstract This study evaluated the dental displacement in dentures included in different flasks and processed by the Australian cycle modified or by microwave. Metal pins were placed on the teeth as reference for measurements: a) Incisal edge of maxillary and mandibular central incisors, buccal cusp of maxillary and…