acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “cold vapor”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Slurry sampling for Hg determination in sediments, sewage sludge and coal samples by cold vapor atomic absorption spectrometry

    Anderson S. Ribeiro, Mariana A. Vieira e Adilson J. CurtiusJournal of the Brazilian Chemical Society2004

    A simple and robust method for the determination of Hg in environmental samples by slurry sampling cold vapor generation atomic absorption spectrometry is proposed. After reducing the sample particles size to < 50 µm in an agate mortar, two procedures were used in the slurry preparation: either using 6.7% v/v nitric…

  2. Determining Mercury in Sediment Samples by Extraction Using a Novel-Chelating Reagent Dithiothreitol (DTT) Followed by Cold Vapor Atomic Fluorescence Spectrometry (CV-AFS)

    Robson M. de Jesus, Geovani C. Brandão, Walter N. L. dos Santos e mais 2Journal of the Brazilian Chemical Society2020

    A new analytical protocol has been developed for the determination of mercury in surface sediments using dithiothreitol (DTT) as a new chelating reagent for the extraction. This protocol requires a small sample mass (250 mg), 4.0 mL of a 0.1 M (pH = 9.0) aqueous DTT solution, and sonication for 30 min, followed by…

  3. Cold vapor atomic absorption spectrometric determination of cadmium after solid phase extraction on modified TiO2 nanoparticles

    Reza Hafezi Moghaddam, Ali Mohammad Haji Shabani, Shayessteh Dadfarnia e mais 1Journal of the Brazilian Chemical Society2014

    Cadmium was quantitatively adsorbed from aqueous sample onto a microcolumn packed with cadion immobilized on sodium dodecyl sulfate-coated TiO2 nanoparticles. The retained cadmium was eluted with 2.5 mol L-1 hydrochloric acid solution and measured by cold vapor atomic absorption spectrometry (CVAAS). The influences of…

  4. A novel approach to cold vapor generation for the determination of mercury in biological samples

    Eder José dos Santos, Amanda Beatriz Herrmann, Vera Lúcia Azzolin Frescura e mais 2Journal of the Brazilian Chemical Society2008

    A novel approach to the generation of mercury vapor at high pH by the simple addition of NaOH or other base to a solution containing mercury ions is described. Subsequent addition of another reducing agent, such as NaBH4 or SnCl2, is unnecessary. Following total dissolution of sample using HNO3 and H2O2 in a closed…

  5. Bipolar plasma vaporization using plasma-cutting and plasma-loop electrodes versus cold-knife transurethral incision for the treatment of posterior urethral stricture: a prospective, randomized study

    Wansong Cai, Zhiyuan Chen, Liping Wen e mais 2Clinics2016

    OBJECTIVE: Evaluate the efficiency and safety of bipolar plasma vaporization using plasma-cutting and plasma-loop electrodes for the treatment of posterior urethral stricture. Compare the outcomes following bipolar plasma vaporization with conventional cold-knife urethrotomy. METHODS: A randomized trial was performed…

  6. Total Mercury Determination in Petroleum Green Coke and Oily Sludge Samples by Cold Vapor Atomic Fluorescence Spectrometry

    Adriana S. Camera, Tatiane A. Maranhão, Fernando J. S. Oliveira e mais 2Journal of the Brazilian Chemical Society2015

    A fast, simple and reliable method for Hg determination in green coke and oily sludge samples by atomic fluorescence spectrometry is described. Microwave digestion and extraction procedures were evaluated for highly complex samples of coke and oily sludge. The concentrations of SnCl2 and HCl to promote Hg vapor, were…

  7. Organic and total mercury determination in sediments by cold vapor atomic absorption spectrometry: methodology validation and uncertainty measurements

    Robson L. Franklin, Jose E. Bevilacqua e Deborah I. T. FavaroQuímica Nova2012citado por 2 artigos

    The purpose of the present study was to validate a method for organic Hg determination in sediment. The procedure for organic Hg was adapted from literature, where the organomercurial compounds were extracted with dichloromethane in acid medium and subsequent destruction of organic compounds by bromine chloride. Total…

  8. Mercury speciation in urban landfill leachate by cold vapor generation atomic absorption spectrometry using ion exchange and amalgamation

    Éder L. M. Flores, José N. G. Paniz, Érico M. M. Flores e mais 2Journal of the Brazilian Chemical Society2009

    This work deals with on line speciation of organic Hg (Hg org) and inorganic Hg (Hg inorg) in urban landfill leachate. Chlorocomplexes of Hg inorg are produced in HCl medium and retained on an anion exchange column. The retained Hg is eluted with NaBH4 in presence of HCl. Hg0 is produced and then measured by cold…

  9. Simultaneous Determination of Furan and Vinyl Acetate in Vapor Phase of Mainstream Cigarette Smoke by GC-MS

    AIFEI XU, ZHONG FAN, ZHIYAN CHEN e mais 9Anais da Academia Brasileira de Ciências2017

    ABSTRACT A simple and sensitive method for simultaneous determination of furan and vinyl acetate (VA) in vapor phase of mainstream cigarette smoke with cold trap and gas chromatography-mass spectrometry (GC-MS) was developed. A Cambridge filter pad (CFP) was placed in front of the impingers of smoking machine to…

  10. Effect of vaporized perfluorocarbon on oxidative stress during the cold ischemia phase of lung graft preservation

    Renata Salatti Ferrari, Leonardo Dalla Giacomassa Rocha Thomaz, Lucas Elias Lise Simoneti e mais 2Jornal Brasileiro de Pneumologia2019

    ABSTRACT Liquid perfluorocarbon (PFC) instillation has been studied experimentally as an adjuvant therapy in the preservation of lung grafts during cold ischemia. The objective of this study was to evaluate whether vaporized PFC is also protective of lung grafts at different cold ischemia times. We performed…